Add RISC-V RPMI device power service support

Joshua Yeong linux-devicetree linux-pm linux-riscv lkml 3 versions – Applied

Status from this message: This series was applied to riscv/linux.git (fixes)

Get series with b4
b4 am [email protected]

Versions newest first · linked by author and title

  1. v3 Latest3 patches 2 repliesApplied 3/3
  2. v22 patches 4 repliesSuperseded
  3. v12 patches 2 repliesSuperseded

Changes in v3 from the cover letter

- Move the MAINTAINERS change into its own patch, and add a new "RISC-V RPMI DEVICE POWER DRIVER" section scoped to this driver and its bindings instead of adding an M: entry to the existing "RISC-V RPMI AND MPXY DRIVERS" section, which covers drivers maintained by others.
- Drop the redundant trailing "bindings" from the dt-bindings subject.
- Compare only the value field of the RPMI power state word. The word also carries a context bit, so a full word comparison would report -EIO after a successful transition, and would drop a domain at probe, whenever the PuC reports context as lost.
- Check the pm_genpd_init() return value and leave a failed domain out of the onecell array. Every failure path in pm_genpd_init() returns before the genpd is linked into gpd_list, so the previous code could hand a half initialised genpd to of_genpd_add_provider_onecell() and then list_del() an uninitialised list head in the unwind loop.
- Set GENPD_FLAG_DEV_NAME_FW. The domain names come from the PuC and are not guaranteed to be unique or non-empty, and were used verbatim as the sysfs and debugfs names, where a duplicate fails device_add() with -EEXIST and takes down the whole provider.

Patches in v3 All 3 applied

#Subject and filesSizeRepliesApplied
1/3dt-bindings: power: Add RPMI device power serviceDocumentation/devicetree/bindings/power/riscv,rpmi-device-power.yaml Documentation/devicetree/bindings/power/riscv,rpmi-mpxy-device-power.yaml+130 -01 replyApplied
2/3pmdomain: riscv: Add RPMI device power servicedrivers/pmdomain/Kconfig drivers/pmdomain/Makefile drivers/pmdomain/riscv/Kconfig +3 more+516 -00 repliesApplied
3/3MAINTAINERS: Add RISC-V RPMI device power driverMAINTAINERS+8 -00 repliesApplied

Reviews trailers per patch

1 of 3 patches has a Reviewed-by or Acked-by.

PatchConor Dooley
1/3R-b
2/3
3/3

Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.

Read the v3 thread

Cover letter [PATCH v3 0/3] Add RISC-V RPMI device power service support

The RISC-V Platform Management Interface (RPMI) specification defines a modular and extensible messaging protocol between the supervisor software and a platform microcontroller (PuC). Among the service groups it defines is the device power service group (service group ID 0x00009), which allows the supervisor to enumerate the power domains of platform devices managed by the PuC, query their attributes, and get/set their power state.

This series adds supervisor-side support for that service group:

- DT bindings for the power domain controller exposed to the supervisor ("riscv,rpmi-device-power") and for the SBI MPXY channel that the SBI implementation uses to expose the service group to the supervisor ("riscv,rpmi-mpxy-device-power").

- A generic power domain (genpd) provider driver under drivers/pmdomain/riscv/ which talks to the PuC over an SBI MPXY mailbox channel. At probe it queries GET_NUM_DOMAINS, then for each domain queries GET_ATTRS for the name and transition latency and GET_STATE for the initial state, and registers the whole set as a onecell genpd provider. Domain power on/off is driven through SET_STATE with the generic ON/OFF power state parameters, so devices can simply reference a domain through the "power-domains" property.

The series is based on the existing RISC-V RPMI/MPXY infrastructure already present in the tree (drivers/mailbox/riscv-sbi-mpxy-mbox.c and include/linux/mailbox/riscv-rpmi-message.h), and only adds the device power service group definitions on top of it.

Changes in v3:
- Move the MAINTAINERS change into its own patch, and add a new "RISC-V RPMI DEVICE POWER DRIVER" section scoped to this driver and its bindings instead of adding an M: entry to the existing "RISC-V RPMI AND MPXY DRIVERS" section, which covers drivers maintained by others.
- Drop the redundant trailing "bindings" from the dt-bindings subject.
- Compare only the value field of the RPMI power state word. The word also carries a context bit, so a full word comparison would report -EIO after a successful transition, and would drop a domain at probe, whenever the PuC reports context as lost.
- Check the pm_genpd_init() return value and leave a failed domain out of the onecell array. Every failure path in pm_genpd_init() returns before the genpd is linked into gpd_list, so the previous code could hand a half initialised genpd to of_genpd_add_provider_onecell() and then list_del() an uninitialised list head in the unwind loop.
- Set GENPD_FLAG_DEV_NAME_FW. The domain names come from the PuC and are not guaranteed to be unique or non-empty, and were used verbatim as the sysfs and debugfs names, where a duplicate fails device_add() with -EEXIST and takes down the whole provider.

v1: https://lore.kernel.org/r/[email protected]
v2: https://lore.kernel.org/r/[email protected]

Testing
=======

The series was tested under QEMU with the RPMI device power service implemented in firmware.

Components:

- OpenSBI: latest master branch
https://github.com/riscv-software-src/opensbi

- QEMU: the RPMI-enabled tree at
https://github.com/yeongjoshua/qemu/tree/rpmi-v11.1.0

Kernel config: enable CONFIG_RISCV_RPMI_DEVICE_POWER (default y on RISC-V when MAILBOX is enabled) along with the SBI MPXY mailbox driver.

Run with:

  qemu-system-riscv64 \
      -M virt -m 2G -smp 4 \
      -bios fw_dynamic.bin \
      -kernel Image \
      -M rpmi=true \
      -nographic \
      -initrd rootfs-busybox.cpio \
      -append "root=/dev/ram rw console=ttyS0,115200 no_console_suspend mem=2048M earlycon=uart8250,mmio,0x10000000"

The RPMI device power domains advertised by the emulated platform microcontroller show up as generic power domains and can be inspected through /sys/kernel/debug/pm_genpd/. The series was additionally booted with CONFIG_PROVE_LOCKING, CONFIG_DEBUG_MUTEXES and CONFIG_DEBUG_ATOMIC_SLEEP enabled, with no lockdep reports.

Joshua Yeong (3):
dt-bindings: power: Add RPMI device power service
pmdomain: riscv: Add RPMI device power service
MAINTAINERS: Add RISC-V RPMI device power driver

 .../power/riscv,rpmi-device-power.yaml        |  65 +++
 .../power/riscv,rpmi-mpxy-device-power.yaml   |  65 +++
 MAINTAINERS                                   |   8 +
 drivers/pmdomain/Kconfig                      |   1 +
 drivers/pmdomain/Makefile                     |   1 +
 drivers/pmdomain/riscv/Kconfig                |  15 +
 drivers/pmdomain/riscv/Makefile               |   3 +
 .../pmdomain/riscv/riscv-rpmi-device-power.c  | 485 ++++++++++++++++++
 include/linux/mailbox/riscv-rpmi-message.h    |  11 +
 9 files changed, 654 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/power/riscv,rpmi-device-power.yaml
 create mode 100644 Documentation/devicetree/bindings/power/riscv,rpmi-mpxy-device-power.yaml
 create mode 100644 drivers/pmdomain/riscv/Kconfig
 create mode 100644 drivers/pmdomain/riscv/Makefile
 create mode 100644 drivers/pmdomain/riscv/riscv-rpmi-device-power.c

base-commit: 8d3ae59288f1e7d58d76558a6ee96d533bc5019f --