hwmon: (lm75) add MAX31875 support
Status from this message: Applied.
Get series with b4
b4 am [email protected]Versions newest first · linked by author and title
- v4 Latest3 patches 3 repliesApplied
- v33 patches 0 repliesSuperseded
- v23 patches 2 repliesSuperseded
Changes in v4 from the cover letter
- driver: skip the alert polarity configuration for the MAX31875. It has no polarity bit, and the bit used for 16-bit chips is part of its conversion rate field.
- driver: set the default resolution and conversion rate at probe so the driver state matches the chip.
- The conversion rate field is D2:D1 of the configuration register (see the datasheet's Configuration Register Definition). It is read here as 0x0600 because the driver reads this register without byte swapping.
Patches in v4 Applied
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/3 | dt-bindings: hwmon: lm75: add MAX31875Documentation/ | +1 | 1 reply | |
| 2/3 | hwmon: (lm75) add MAX31875 documentationDocumentation/ | +4 | 1 reply | |
| 3/3 | hwmon: (lm75) add MAX31875 supportdrivers/ drivers/ | +30 | 1 reply |
Reviews trailers per patch
1 of 3 patches has a Reviewed-by or Acked-by.
| Patch | Conor Dooley |
|---|---|
| 1/3 | A-b |
| 2/3 | |
| 3/3 |
Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.
Cover letter [PATCH v4 0/3] hwmon: (lm75) add MAX31875 support
Add support for the Analog Devices MAX31875 I2C temperature sensor by extending the existing lm75 driver.
The MAX31875 provides a 16-bit configuration register, selectable resolution of 8, 9, 10, or 12 bits, conversion rates of 125 ms, 250 ms, 1 s, or 4 s, and an alarm output.
Changes since v3:
- driver: skip the alert polarity configuration for the MAX31875. It has no polarity bit, and the bit used for 16-bit chips is part of its conversion rate field.
- driver: set the default resolution and conversion rate at probe so the driver state matches the chip.
- The conversion rate field is D2:D1 of the configuration register (see the datasheet's Configuration Register Definition). It is read here as 0x0600 because the driver reads this register without byte swapping.
Tested on a Raspberry Pi 4B with a MAX31875: defaults are restored at probe after the chip is set to 12-bit/125 ms, update_interval selects each of the four conversion rates without changing the resolution, and temp1_alarm follows temp1_max. This was run on the Raspberry Pi 6.12 tree, which reads the configuration register byte-swapped, so the equivalent bit positions were used there.
Changes since v2:
- dt-bindings: expand the commit message to explain why the MAX31875 needs its own compatible string instead of reusing an existing lm75-family one, and pick up Conor Dooley's Acked-by given conditional on that fix.
- driver: drop the .resolutions table, which incorrectly tied resolution to the sample-time index even though the two are independently configurable on this chip (Guenter Roeck).
- driver: use the BIT() idiom for the alarm bit read to match the rest of the file (Guenter Roeck).
Changes since v1:
- Rework the implementation to use the existing lm75 driver instead of the previously selected max31827 base driver.
- Add the MAX31875 Device Tree binding, documentation, and driver configuration for resolution, conversion rate, and alarm reporting.
John Erasmus Mari Geronimo (3):
dt-bindings: hwmon: lm75: add MAX31875
hwmon: (lm75) add MAX31875 documentation
hwmon: (lm75) add MAX31875 support
.../devicetree/bindings/hwmon/lm75.yaml | 1 + Documentation/hwmon/lm75.rst | 6 ++-- drivers/hwmon/Kconfig | 2 +- drivers/hwmon/lm75.c | 30 ++++++++++++++++++- 4 files changed, 35 insertions(+), 4 deletions(-)
Signature · 1 line