net/mlx5: LAG over VFs/SFs (virtual LAG)
Get series with b4
b4 am [email protected]Versions newest first · linked by author and title
- v2 Latest posting 2/25 patches 3 repliesIn review
- v2 posting 1/210 patches 5 repliesApplied 10/10
- v115 patches 9 repliesSuperseded
Changes in v2 from the cover letter
- Split the patch set to ease the review: this is v1 patches 11-15; v1 patches 1-10 are sent as "net/mlx5: LAG, preparations for LAG over VFs/SFs", which this series depends on.
- Patch 1: commit message describes which non-PF eswitches take the nested metadata layout, and no longer implies a PF may have the virt LAG capabilities. The reg_c_0 comment in include/linux/mlx5/eswitch.h describes the nested layout (Sashiko).
- Patch 3: commit message names the field ldev->max_fns, not ldev->max_funcs (Sashiko).
- Patch 5: do not assign an RDMA TX port affinity on a virt LAG capable function, and do not register the multipath FIB notifier for a virt LAG (Sashiko).
Patches in v2 posting 2/2 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 1/5 | net/mlx5: E-switch, add match-metadata allocator for nested VF/SF eswitchesdrivers/ drivers/ drivers/ +1 more | +70 | 1 reply | |
| 2/5 | net/mlx5: E-switch, match master egress rule by vport metadatadrivers/ | +55 | 0 replies | |
| 3/5 | net/mlx5: E-switch, drop master egress rule under a SW vport LAGdrivers/ drivers/ drivers/ +1 more | +29 | 1 reply | |
| 4/5 | net/mlx5e: Register eswitch-manager VF/SF self-port with switch-iddrivers/ | +5 | 0 replies | |
| 5/5 | net/mlx5: LAG, enable LAG over functions that do not represent a physical portdrivers/ drivers/ drivers/ | +26 | 1 reply |
Reviews trailers per patch
All 5 patches have a Reviewed-by or Acked-by.
| Patch | Moshe Shemesh | Mark Bloch | Akiva Goldberger |
|---|---|---|---|
| 1/5 | R-b | R-b | |
| 2/5 | R-b | R-b | R-b |
| 3/5 | R-b | R-b | |
| 4/5 | R-b | R-b | |
| 5/5 | R-b | R-b |
Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes. Scroll the table sideways for all 3 reviewers.
Cover letter [PATCH net-next V2 0/5] net/mlx5: LAG over VFs/SFs (virtual LAG)
This is V2 of the top patches submitted previously here [1].
This series by Shay enables a LAG over functions that do not represent a physical port - a "virtual LAG" (virt LAG) of VFs or SFs acting as nested e-switch managers. New FW lets a VF/SF front the physical uplinks through a multi-uplink e-switch; such a function reports num_lag_ports < 2 and drives port selection via the e-switch (port_select_eswitch) rather than the HW port-selection flow table. A virt LAG is therefore a software-managed, shared-FDB MPESW LAG: the driver builds the LAG demux and vport-LAG in software.
It depends on [2] which prepared the LAG core.
The patches fall into two parts.
E-switch and representors (patches 1, 2, 3, 4)
- A dedicated match-metadata allocator for nested VF/SF e-switches, so VFs/SFs sharing an FDB get unique source-port metadata.
- Match the master egress bounce rule by vport metadata.
- Drop the master egress rule while a software vport LAG is installed:
the SW emulation is a rule in the slave's egress ACL and cannot act on a packet the master egress rule redirects after the FDB. Restore it when the vport LAG is removed.
- Register a VF/SF e-switch-manager self-port with a switch-id so it groups with the representors it manages.
Virtual LAG enablement (patch 5)
- Enable LAG over functions that do not represent a physical port - the gate that admits a virt LAG.
Regards,
Tariq
[1] https://lore.kernel.org/all/[email protected]/
[2] https://lore.kernel.org/all/[email protected]/
V2:
- Split the patch set to ease the review: this is v1 patches 11-15; v1 patches 1-10 are sent as "net/mlx5: LAG, preparations for LAG over VFs/SFs", which this series depends on.
- Patch 1: commit message describes which non-PF eswitches take the nested metadata layout, and no longer implies a PF may have the virt LAG capabilities. The reg_c_0 comment in include/linux/mlx5/eswitch.h describes the nested layout (Sashiko).
- Patch 3: commit message names the field ldev->max_fns, not ldev->max_funcs (Sashiko).
- Patch 5: do not assign an RDMA TX port affinity on a virt LAG capable function, and do not register the multipath FIB notifier for a virt LAG (Sashiko).
V1:
https://lore.kernel.org/all/[email protected]/
Answers to sashiko comments on v1:
net/mlx5: E-switch, add match-metadata allocator for nested VF/SF eswitches
Review
Quoted 2 lines
(quoted diff) +2
-0+ if (!mlx5_core_is_pf(esw->dev) && !mlx5_virt_lag_nonmember(esw->dev)) + return mlx5_nested_esw_match_metadata_alloc(esw);
Q: mlx5_virt_lag_nonmember() is false when virt LAG is unsupported, so a standalone non-PF eswitch without virt LAG support takes the nested path and fails switchdev with -ENOSPC. Could it keep the PFNUM allocator?
[SD] A non-PF eswitch manager without virt LAG support doesn't exist at the moment. FW doesn't expose such a VF/SF.
Q: The nested allocator gives each eswitch 254 ids (2-255), yet a nested eswitch can enumerate up to max_num_sf SF vports, each taking an id. Also, LAG admission accepts slots 0-254, while the allocator gives no metadata to slots above 239. Can switchdev fail with -ENOSPC in either case?
[SD] Both are theoretical only; there is no such use case.
net/mlx5: E-switch, match master egress rule by vport metadata
Q: Is mlx5_virt_lag_is_supported() enough to decide on reg_c_0 matching here? Outside MPESW both uplinks share MLX5_ESW_METADATA_RSVD_UPLINK. A PF that reports the virt LAG capability bits and also supports SD would create a shared FDB with only the reserved uplink metadata in place. The commit "add match-metadata allocator for nested VF/SF eswitches" says PFs may have virt LAG capabilities.
[SD] This is not correct, PFs cannot have virt LAG caps; FW exposes them only on VF/SF nested eswitch managers. The misleading wording in the "add match-metadata allocator" commit message is fixed in v2.
net/mlx5: E-switch, drop master egress rule under a SW vport LAG
Q: If restoring the master egress rule fails in mlx5_eswitch_offloads_vport_lag_del_one(), only a warning is printed and the slave rule is removed anyway, so the slave loses forwarding. Should the error be propagated?
[SD] If restoring fails, FW is dead, and the lost traffic is not the real problem at that point.
net/mlx5e: Register eswitch-manager VF/SF self-port with switch-id
Q: The only condition here is MLX5_ESWITCH_MANAGER(mdev), but mlx5_query_nic_sw_system_image_guid() makes a VF/SF id differ from the PF's only when virt LAG is supported. Can a VF/SF eswitch manager without the virt LAG caps give its uplink netdev the same phys_switch_id as its parent PF's switch? Should this branch set the switch_id only when the resulting GUID differs from the PF's?
[SD] A VF/SF eswitch manager without the virt LAG caps doesn't exist. New FW will let a VF/SF be an eswitch manager only as a nested eswitch manager, and such a function reports multi_uplink_eswitch, lag_master and num_lag_ports < 2, so mlx5_query_nic_sw_system_image_guid() gives it the VF/SF marker and its switch_id differs from its PF's.
Q: If the system image GUID query fails, the self-port is registered with an empty switch id, and nothing fixes it later. Should the error be propagated?
[SD] This is the same behavior as the existing PF self-port path.
net/mlx5: LAG, enable LAG over functions that do not represent a physical port
Review
Quoted 3 lines
(quoted diff) +1
-1- if (group_id) + if (group_id || ldev->virt_lag) return 0;
Q: mlx5_lag_set_vports_agg_speed() iterates ports only, so a virt LAG gets no aggregate vport speed, and its members skip the port-change notifier. Is there an alternative virt LAG speed policy?
[SD] This is on purpose.
Q: members_show() uses mlx5_ldev_for_each(), so the debugfs members file is empty for a virt LAG. Could it list all members?
[SD] Left as is for now, since all VFs in the system share the LAG.
Review
Quoted 3 lines
(quoted diff) +1
-1- if (!mlx5_lag_is_supported(dev)) + if (!mlx5_lag_is_supported(dev) && !mlx5_virt_lag_is_supported(dev)) return;
Q: mlx5_virt_lag_is_supported() checks multi_uplink_eswitch, lag_master and num_lag_ports < 2, but it does not exclude PFs with mlx5_core_is_pf(). Can a PF with these caps also get here? Such a PF would keep the plain PF devcom key and get an ldev with virt_lag = true. Should this gate exclude PFs as well?
[SD] No PF has these caps. FW exposes multi_uplink_eswitch together with lag_master and num_lag_ports < 2 only on the VF/SF that acts as a nested eswitch manager, so mlx5_virt_lag_is_supported() is a pure capability check on purpose, with no is_vf()/is_sf() in it. The !mlx5_core_is_pf() tests in eswitch_offloads.c select an id layout for non-PF eswitches; they don't mean a PF can be virt-capable.
Review
Quoted 2 lines
(quoted diff) +2
-0+ err = xa_alloc(&ldev->fns, &idx, fn, XA_LIMIT(0, U8_MAX - 1), + GFP_KERNEL);
Q: mlx5_virt_lag_is_supported() has no limit on the number of members. Once 255 fns exist, the next xa_alloc() returns -EBUSY, and mlx5_lag_add_mdev() only bails out on -EOPNOTSUPP. Can the 256th function keep retrying inside mlx5_load() forever?
[SD] The retry loop is pre-existing: mlx5_lag_add_mdev() retried every error before this series as well, and no HW exposes this yet; -EBUSY can only be returned by future HW. The fix will be sent to net as a separate patch.
Q: mlx5_ib_modify_dct() picks the DCT port with get_tx_affinity_rr() whenever mlx5_lag_is_active(), bypassing mlx5_ib_lag_should_assign_affinity(). If mlx5_eth_lag_init() left lag_active unset, e.g. without a LAG flow namespace, the divisor is num_lag_ports, which is 0 on such a function. Can this divide by zero?
[SD] This is theoretical only; there is no such setup.
Q: end_flow_index is inclusive, so the master egress group spans max_fns + 1 entries in a table created with max_fte = max_fns. With max_fns == 128 the table is exactly 128 entries. Can the group creation fail?
[SD] This is theoretical only; there is no such use case.
Shay Drory (5):
net/mlx5: E-switch, add match-metadata allocator for nested VF/SF
eswitches
net/mlx5: E-switch, match master egress rule by vport metadata net/mlx5: E-switch, drop master egress rule under a SW vport LAG net/mlx5e: Register eswitch-manager VF/SF self-port with switch-id net/mlx5: LAG, enable LAG over functions that do not represent a
physical port
drivers/infiniband/hw/mlx5/mlx5_ib.h | 3 + .../ethernet/mellanox/mlx5/core/en/devlink.c | 5 + .../net/ethernet/mellanox/mlx5/core/eswitch.h | 3 +- .../mellanox/mlx5/core/eswitch_offloads.c | 150 +++++++++++++++--- .../net/ethernet/mellanox/mlx5/core/lag/lag.c | 49 ++++-- .../ethernet/mellanox/mlx5/core/lag/mpesw.c | 4 +- .../mellanox/mlx5/core/lag/shared_fdb.c | 6 +- .../ethernet/mellanox/mlx5/core/mlx5_core.h | 1 + include/linux/mlx5/eswitch.h | 4 + 9 files changed, 185 insertions(+), 40 deletions(-)
base-commit: 2208ab00f4f213ade91ab775e7f8c4dacdcc856e
Signature · 1 line
2.44.0