Cover letter [U-Boot-Users] [patch 0/6] DM9000: Several fixes/cleanups for the DM9000A controller
Quoted 6 lines · Ben Warren

Wolfgang,

Is the merge window open for the rest of today, or is it closed? If open, I'll look at this patch set later today and act on it. Otherwise this goes into the 'for later' bin.

Hi,

this patch does not work on the trizeps board. I get the following error:

$ tftp 0xa0010000 u-boot.bin
dm9000 i/o: 0x8000000, id: 0x90000a46

DM9000: running in 32 bit mode

MAC: 00:50:c2:3b:8f:0a

operating at 100M full duplex mode

TFTP from server 192.168.2.14; our IP address is 192.168.2.77

Filename 'u-boot.bin'.
Load address: 0xa0010000

Loading: DM9000 error: status check fail: 0x6d

I have only applied the patches and tried a quick check...The bus width is correctly recognized but there is no data transfer.

However, the ethernet controller works with the current driver:

$ tftp  0xa0010000 u-boot.bin
dm9000 i/o: 0x8000000, id: 0x90000a46

MAC: 00:50:c2:3b:8f:0a

operating at 100M full duplex mode

TFTP from server 192.168.2.14; our IP address is 192.168.2.77

Filename 'u-boot.bin'.
Load address: 0xa0010000

Loading: ###########

done

Bytes transferred = 160180 (271b4 hex)

Regards,
Stefano

Signature · 5 lines
=====================================================================
DENX Software Engineering GmbH,     MD: Wolfgang Denk & Detlev Zundel
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany