Switch internal registers address to 0xF1 on Armada 370/XP
Get series with b4
b4 am [email protected]Versions newest first
- v1 Latest1 of 9 patches 0 repliesNew
1 of 9 patches is in this archive. The cover letter announces 9.
Patches in v1 No applies recorded yet
| # | Subject and files | Size | Replies | Applied |
|---|---|---|---|---|
| 9/9 | arm: mvebu: switch internal register address at runtime if needed | +0 | 0 replies |
Reviews trailers per patch
No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.
Cover letter [PATCH 0/9] Switch internal registers address to 0xF1 on Armada 370/XP
Quoted 8 lines · Willy Tarreau
On Tue, May 21, 2013 at 12:33:25PM +0200, Thomas Petazzoni wrote:
(...)Quoted 5 lines
As it was explained above, we unfortunately can't read the current base address of the internal register window, so we need a different mechanism to know if the bootloader has done the remapping at
0xF1000000(new generation bootloader) or has left the internal registers at0xD0000000(old generation bootloader).
Quoted 6 lines
Just out of curiosity, what happens if you touch the register at the wrong address ? I mean, if you blindly write to the 0xD0xxxxxx address that you want the registers to be mapped at 0xF1xxxxxx. Will the chip hang, will it silently ignore the sequence ? Because maybe you don't need to detect using CP15 whether the remapping was done, you could simply perform it unconditionally.
Willy,
I tried the above on Dove which is possibly affected by the workaround as it is also ARMv7. In Dove you can access unmapped addresses without any problems, but as Thomas already stated Armada 370/XP just hang. Must be some default AHB slave in Dove, which Armada 370/XP is missing.
Sebastian