Skip to content

Fixed bugs in pl080

Tao Ding qemu-arm qemu-devel 1 version In review

Get series with b4
b4 am [email protected]

Versions newest first

  1. v1 Latest3 patches 4 repliesIn review

Patches in v1 No applies recorded yet

#Subject and filesSizeRepliesApplied
1/3An interrupt is generated after the DMA transfer complete.hw/dma/pl080.c+1 -00 replies
2/3The swidth and dwidth of pl080 are not equal.hw/dma/pl080.c+20 -125 replies
3/3The LLI of pl080 should be aligned with 4 bytes.hw/dma/pl080.c+7 -51 reply

Reviews trailers per patch

1 of 3 patches has a Reviewed-by or Acked-by.

PatchPeter Maydell
1/3
2/3
3/3R-b

Trailers given in replies are filled; those carried in the patches from earlier versions are outlined with dashes.

Read the v1 thread

Cover letter [PATCH v1 0/3] Fixed bugs in pl080

Hi all,
When I tested pl080 using the existing dmatest tool in Linux,
I found that pl080 could not output the results correctly.
The main issues involved are inconsistent source and destination bit widths, misalignment of LLI, which can lead to incorrect data and even cause qemu crashes.

Tao Ding (3):
An interrupt is generated after the DMA transfer complete. The swidth and dwidth of pl080 are not equal. The LLI of pl080 should be aligned with 4 bytes.

 hw/dma/pl080.c | 45 ++++++++++++++++++++++++++++-----------------
 1 file changed, 28 insertions(+), 17 deletions(-)

base-commit: 1fd5ff9d76d23ab23a68419cbc76d5ee33e8b455

Signature · 1 line