Skip to content

Add adaptive NVMe link rate switching function

Liao Xuan linux-nvme linux-pci lkml 1 version New

Get series with b4
b4 am [email protected]

Versions newest first

  1. v1 Latest3 patches 0 repliesNew

Patches in v1 No applies recorded yet

#Subject and filesSizeRepliesApplied
1/3nvme: Add adaptive PCIe link rate switching functiondrivers/nvme/host/Kconfig drivers/nvme/host/Makefile drivers/nvme/host/core.c +4 more+433 -00 replies
2/3nvme: Add hysteresis and idle detection to link rate switchingdrivers/nvme/host/nvme.h drivers/nvme/host/speed_switch.c+51 -60 replies
3/3nvme: Expose link rate switching tunables via sysfsdrivers/nvme/host/nvme.h drivers/nvme/host/speed_switch.c drivers/nvme/host/sysfs.c+160 -10 replies

Reviews trailers per patch

No Reviewed-by, Acked-by or Tested-by trailers for v1 yet.

Read the v1 thread

Cover letter [PATCH 0/3] Add adaptive NVMe link rate switching function

From: Liao Xuan <[email protected]>

NVMe devices are commonly left trained at the maximum PCIe link rate even when there is little or no I/O activity, which wastes power in both the device and the surrounding platform.

This series adds adaptive PCIe link rate switching to the NVMe host driver. The link is downgraded to a configurable minimum rate when I/O activity is low to save power, and upgraded back to the maximum supported rate as soon as the workload requires it, so that peak performance is maintained under load.

The amount of transferred data is accumulated on the submission path with per-CPU counters and evaluated by a per-controller timer. The switch threshold is derived from the bandwidth of the minimum and maximum link rates such that the extra time required to transfer the data at the minimum rate does not exceed the estimated link retraining time. The controller queues are frozen while the link is retrained and resumed afterwards, so no I/O is lost or times out during the switch.

The main functions of each patch are as follows:
1. Patch 1 adds the core switching functionality. It uses the target link speed interface of the PCIe bandwidth controller, which is exported for this purpose.

2. Patch 2 adds hysteresis and idle detection to the switching policy. The link is upgraded immediately once the threshold is exceeded, but only downgraded after a number of consecutive below-threshold windows, which prevents excessive rate toggling under fluctuating workloads. Monitoring is stopped after a period of inactivity and re-armed by the next I/O.

3. Patch 3 exposes the switching parameters (enable, monitor_interval, min_speed, up_threshold, down_threshold) via sysfs so that the power/performance trade-off can be tuned at runtime without a reboot.

The feature is currently enabled on Hygon platforms.

Liao Xuan (3):
nvme: Add adaptive PCIe link rate switching function
nvme: Add hysteresis and idle detection to link rate switching
nvme: Expose link rate switching tunables via sysfs

 drivers/nvme/host/Kconfig        |  10 +
 drivers/nvme/host/Makefile       |   1 +
 drivers/nvme/host/core.c         |   4 +
 drivers/nvme/host/nvme.h         |  50 ++++
 drivers/nvme/host/pci.c          |   4 +
 drivers/nvme/host/speed_switch.c | 424 +++++++++++++++++++++++++++++++
 drivers/nvme/host/sysfs.c        | 143 +++++++++++
 drivers/pci/pcie/bwctrl.c        |   1 +
 8 files changed, 637 insertions(+)
 create mode 100644 drivers/nvme/host/speed_switch.c
Signature · 1 line