Dear all,

We are trying to port u-boot onto Rattler board(MPC8280). We had
done the relevant porting and but are unable to test the same due to the problem mentioned below:

We are using BDI2000 to program the Rattler board. Our configuration file for BDI2000 (which we had written) seems ok as we were able to access the board using INFO, RES and also was able to dump the memory starting from the PC (program counter). But when I tried to erase the Flash, it erased for the first time. But subsequent erase is not happening, it says

COP status is 0xAD #PPC:unexpected response from target Check running state failed Target PVR is 0x0000 0000 Resetting target failed

After this error I am unable to do anything with the board. Can anyone give me some pointers for analyzing this problem? BDI2000 didn't have support for AM29LV641D Flash chips so I had selected AM29F type chips. Please do excuse me if this is off the topic but I thought some people might have faced similar problems. Hence I had mailed to this group. Please do help me out with this problem?

I can share the BDI2000 configuration file which we had modified.

Thanks.
srivats

#1 lore raw
Quoted 7 lines · In message <000301c52a30$61255300$1269cb0a@bgcw301> you wrote:

We are using BDI2000 to program the Rattler board. Our configuration file for BDI2000 (which we had written) seems ok as we were able to access the board using INFO, RES and also was able to dump the memory starting from the PC (program counter). But when I tried to erase the Flash, it erased for the first time. But subsequent erase is not happening, it says

You probably erased the HRCW, and then power cycled the system.

Quoted 2 lines

After this error I am unable to do anything with the board. Can anyone give me some pointers for analyzing this problem? BDI2000 didn't have

Check your hardware documentation how to enable the default processor configuration to allow it to come up without a valid HRWC in flash. There is probably some RSTCNF jumper or similar...

Best regards,

Wolfgang Denk

Signature · 4 lines
Software Engineering:  Embedded and Realtime Systems,  Embedded Linux
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
Life would be so much easier if we could  just  look  at  the  source
code.                                                   -- Dave Olson
author
#2 lore raw

Thanks Mr.Wolfgang. That input really helped us out.

But when we power up the target (MPC8280 based Rattler board), it is getting continuous reset. Previously with the same configuration file it wasn't so. Do we need to make any change in the configuration file? Again Thanks for the input.

With Thanks and Best Regards,
C.R.Srivatsan

#3 lore raw
Quoted 4 lines · In message <001001c52a45$8dbb4ea0$1269cb0a@bgcw301> you wrote:

But when we power up the target (MPC8280 based Rattler board), it is getting continuous reset. Previously with the same configuration file it wasn't so. Do we need to make any change in the configuration file?

How could I guess? I don't know your hardware, I don't know which changes you made to port U-Boot to that hardware, I don't know if you configured the BDI correctly - I don't even know if you're talking about the configuration file for the BDI2000 or for U-Boot...

Sorry...

Wolfgang Denk

Signature · 4 lines
Software Engineering:  Embedded and Realtime Systems,  Embedded Linux
Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: wd at denx.de
Power is danger.
	-- The Centurion, "Balance of Terror", stardate 1709.2
author
#4 lore raw

Thanks for your help Mr.Wolfgang.

The problem was in the BDI2000 configuration file. IMMR was not reconfigured to 0x00000000 (I was using the default value). I am really grateful to you for the support extended.

Regards,
C.R.Srivatsan

#5 lore raw
In reply to Srivatsan
Quoted 9 lines · Srivatsan

Thanks Mr.Wolfgang. That input really helped us out.

But when we power up the target (MPC8280 based Rattler board), it is getting continuous reset. Previously with the same configuration file it wasn't so. Do we need to make any change in the configuration file? Again Thanks for the input.

With Thanks and Best Regards,
C.R.Srivatsan

I assume you are saying that you were successful in asserting RSTCONF and programming the HRCW back in.
* Is it the _correct_ HRCW? Do you know what it was previously?
* Did you _power cycle_ the board with RSTCONF deasserted? (the HRCW only is read on a _power cycle_)

My experience (not with the Rattler) is that boards don't run well with RSTCONF asserted. In my experience, I assert RSTCONF, program the HRCW (and optionally u-boot), and then _power cycle_ the board. At that point, the board should be functional enough to program u-boot (or whatever) into it, reset, and run.

gvb