Skip to contentSkip to conversation

thermal: exynos: Add error handling for temperature code

PATCH New Jonghwan Choi 1 participant 1 message Nov 28, 2012

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 2/2 thermal: exynos: Add error handling for temperature code

If temperature code is invalid, it should be handled.

---
 drivers/thermal/exynos_thermal.c |    8 ++++++--
 1 files changed, 6 insertions(+), 2 deletions(-)
(quoted diff) +0 -0

b/drivers/thermal/exynos_thermal.c
index dc2ad6c..78c5c08 100644

drivers/thermal/exynos_thermal.c +0 -0
@@ -346,15 +346,19 @@ static int exynos_get_temp(struct thermal_zone_device

*thermal,
unsigned long *temp)

 {
        void *data;

+ int tmp;

        if (!th_zone->sensor_conf) {
                pr_info("Temperature sensor not initialised\n");
                return -EINVAL;
        }
        data = th_zone->sensor_conf->private_data;
-       *temp = th_zone->sensor_conf->read_temperature(data);
+       tmp = th_zone->sensor_conf->read_temperature(data);
+       if (tmp < 0)
+               return tmp;
+
        /* convert the temperature into millicelsius */
-       *temp = *temp * MCELSIUS;
+       *temp = tmp * MCELSIUS;
        return 0;

}

--
1.7.4.1