Uncompress Ok, but cannot run linux kernel...
Quoted 7 lines
turn_on_mmu:..... SYNC RFI
Quoted 14 lines
I am dealing with same problem. After the rfi (on
turn_on_mmu) instruction an signal is generated and the progam counter is lost. When performing an rfi most of the bits of the SRR1 registers become the MSR bits and the SRR0 register become the next instruction pointer (NIA). I read the manual and if the new MSR value enables some pending exceptions then this exceptions are processed by exception priority. The bits modified after the rfi areMSR_IR&MSR_DRso I think (I am not sure yet) this bits enables a waiting exception of some kind and when the rfi is processed the exception is executed. gdb only said it recevies a SIGSTOP signal. I will be working with that today. If I found anything I will let you know.
Now I can "turn_on_mmu" and run "start_here" . I make a mistake when I try to debug by outputing a character vi SERIAL Port after "turn_on_mmu". The serial port IO is 0xfe0003f8, and the "initial_bats" only do the physical address 0~256M to virtual address 0xc0000000~0xc0000000+256M memory-mapping. To make the serial port output work, we have to do additional memory-mapping from physical address 0xf000000-0xffffffff to virtual address 0xf0000000~0xffffffff as following:
initial_bats:
......
......
mtspr DBAT0L,r8
mtspr DBAT0U,r11
mtspr IBAT0L,r8
mtspr IBAT0U,r11/*the start added lines */
lis r9,0xf000
ori r9,r9,0x1ffe
lis r8,0xf000
ori r8,r8,0x2a
mtspr DBAT1L,r8
mtspr DBAT1U,r9/*the end added lines*/
isync
blr
Now I meet a new problem. I can run through here:start_here:
...
bl identify_machine
bl MMU_init
lis r4,2f@h
ori r4,r4,2f@l
tophys(r4,r4)
li r3,MSR_KERNEL & ~(MSR_IR|MSR_DR)
FIX_SRR1(r3,r5)
mtspr SRR0,r4
mtspr SRR1,r3
SYNC
RFI
/*Here I add my serial output codes, but it outputs nothing. System seems
to halt here?*/
2:
sync
tlbia
sync
Do you have any ideas?
thank you very much.
machael thailer
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/
Michael,
Please see comments below..
Quoted 68 lines · machael thailer
Quoted 7 lines
turn_on_mmu:..... SYNC RFIQuoted 14 lines
I am dealing with same problem. After the rfi (on
turn_on_mmu) instruction an signal is generated and the progam counter is lost. When performing an rfi most of the bits of the SRR1 registers become the MSR bits and the SRR0 register become the next instruction pointer (NIA). I read the manual and if the new MSR value enables some pending exceptions then this exceptions are processed by exception priority. The bits modified after the rfi areMSR_IR&MSR_DRso I think (I am not sure yet) this bits enables a waiting exception of some kind and when the rfi is processed the exception is executed. gdb only said it recevies a SIGSTOP signal. I will be working with that today. If I found anything I will let you know.Now I can "
turn_on_mmu" and run "start_here" . I make a mistake when I try to debug by outputing a character vi SERIAL Port after "turn_on_mmu". The serial port IO is0xfe0003f8, and the "initial_bats" only do the physical address 0~256M to virtual address 0xc0000000~0xc0000000+256M memory-mapping. To make the serial port output work, we have to do additional memory-mapping from physical address 0xf000000-0xffffffff to virtual address 0xf0000000~0xffffffff as following:
initial_bats:...... ...... mtspr DBAT0L,r8 mtspr DBAT0U,r11 mtspr IBAT0L,r8 mtspr IBAT0U,r11/*the start added lines */
lis r9,0xf000 ori r9,r9,0x1ffe lis r8,0xf000 ori r8,r8,0x2a mtspr DBAT1L,r8 mtspr DBAT1U,r9/*the end added lines*/
isync
blrNow I meet a new problem. I can run through here:
start_here:
...
blidentify_machine
blMMU_init
lis r4,2f@h
ori r4,r4,2f@l
tophys(r4,r4)
li r3,MSR_KERNEL & ~(MSR_IR|MSR_DR)
FIX_SRR1(r3,r5)
mtspr SRR0,r4
mtspr SRR1,r3
SYNC
RFI/*Here I add my serial output codes, but it outputs nothing. System seems
to halt here?*/
Quoted 7 lines
2:
sync
tlbia
syncDo you have any ideas?
thank you very much.
Note that it is loading the "physical" address of the "2:" label into r4. What its doing, is its telling the CPU to turn off MMU (BAT mapping) and then jumping to the "2:" label. If you add your serial output after the "2:" label, it should work again.
The next stage would be to make sure MMU_init() in arch/ppc/mm/init.c will set up the right BATs you need as well (f0000000-0xffffffff), As after all hash tables are modified and such, it will then write out the new BATs saved in the "BATS" variable from MMU_init(), and then will jump to start_kernel() after turning MMU on for the last time.
Hope this helps...
Paul W.
Quoted 6 lines
machael thailer
** Sent via the linuxppc-embedded mail list. See http://lists.linuxppc.org/