Skip to contentSkip to conversation

good drive / bad drive (maxtor topic)

DISCUSSION Mark Klarzynski 2 participants 2 messages Nov 24, 2004 – Nov 25, 2004 libata

lore
Share & tools
lore
#0 lore raw

In the world of hardware raid we decide that a drive has failed based on various criteria, one of which is the obvious 'has the drive responded' within a set time. This set time various depending on the drive, the application, the load etc. This 'timeout' value is realistically between 6 and 10 seconds. There is no real formula, just lots of experience. Set it too short and drives will look failed too often, set it too long and you risk allowing a suspect drive to continue.

Once we detect a timeout we have to decide what to with it. in SCSI we issue a scsi bus rest (hardware reset on the bus).. the reason we do this (and all hardware raid manufactures) is because life is just that
way. drives do lock up. We issue up to 3 resets, and then fail. This
is extremely effective and does exactly what it is supposed to do. Often the drive will never cause an issue again. if it is faulty then it will escalate and fail.

We have utilised countless sata drives, and timeouts are by far the most significant failure we see and as sata (although its hard to tell much else on sata).. but it is therefore imperative that the timeout values are correct for the drive and the application.

But the point is that we do not see anywhere near the failure rates on the Maxtor's that you guys are mentioning. Also, if we trial sata's on different hardware RAID's we see differing failure rates... (i.e. ICP come in higher then 3ware, which are higher than the host independent raids we have tested and so on)

So I am wondering if it is worth thinking about the timeout values? And what do you do once the drive has timed out?

I am seeing some tremendous work going on in this group and without a doubt this community is going to propel MD to enterprise level raid one day. so this is honestly meant as constructive and is based on way too many years designing raid solutions. i.e. I'm not looking to start an argument simply offering some information.

#1 lore raw

Well, I don't class a drive as failed unless it fails the drive manufacturers test suite.

One other problem with Maxtor is that the test application needs DOS and won't run on VIA or Silicon Image motherboard controllers - so you'd better have a test rig with a decent SATA controller in just waiting to test failed Maxtors ;)

Last time it failed and had an obvious write problem so I just sent it back. Next time I'll see about creating a boot-cd with freedos and the maxtor test app.

I have now got 6 Maxtor drives in my array - one failed and was accepted as faulty by the vendor and replaced. Another threw a fault that hasn't recurred. Maybe it remapped a block noisily? Maybe it was a timeout? It was inconvenient because you go into a 'fragile' mode. Now of course I have a hot spare - but I'm wondering about raid6.

As for enterprise raid - have you seen EVMS recently?
I installed and configured it but reverted to raw md/lvm2 after:
* dm bbr claimed that I had 320 bad blocks on *all* my disks - hmmm
* the lvm2 manager wouldn't _quite_ build properly so I had to do it manually
* the raid5 manager wouldn't let me create a degraded array (which I needed to do)

And I have enough stability issues without another 'almost there' component.

It's looking damned good though.

sorry for wandering a bit OT :)

David

Quoted 47 lines · Mark Klarzynski

In the world of hardware raid we decide that a drive has failed based on various criteria, one of which is the obvious 'has the drive responded' within a set time. This set time various depending on the drive, the application, the load etc. This 'timeout' value is realistically between 6 and 10 seconds. There is no real formula, just lots of experience. Set it too short and drives will look failed too often, set it too long and you risk allowing a suspect drive to continue.

Once we detect a timeout we have to decide what to with it. in SCSI we issue a scsi bus rest (hardware reset on the bus).. the reason we do this (and all hardware raid manufactures) is because life is just that
way. drives do lock up. We issue up to 3 resets, and then fail. This
is extremely effective and does exactly what it is supposed to do. Often the drive will never cause an issue again. if it is faulty then it will escalate and fail.

We have utilised countless sata drives, and timeouts are by far the most significant failure we see and as sata (although its hard to tell much else on sata).. but it is therefore imperative that the timeout values are correct for the drive and the application.

But the point is that we do not see anywhere near the failure rates on the Maxtor's that you guys are mentioning. Also, if we trial sata's on different hardware RAID's we see differing failure rates... (i.e. ICP come in higher then 3ware, which are higher than the host independent raids we have tested and so on)

So I am wondering if it is worth thinking about the timeout values? And what do you do once the drive has timed out?

I am seeing some tremendous work going on in this group and without a doubt this community is going to propel MD to enterprise level raid one day. so this is honestly meant as constructive and is based on way too many years designing raid solutions. i.e. I'm not looking to start an argument simply offering some information.

-
To unsubscribe from this list: send the line "unsubscribe linux-ide" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html