crimson-osd vs legacy-osd: should the perf difference be already noticeable?
Subject: crimson-osd vs legacy-osd: should the perf difference be already noticeable?
Hi folks,
I was curios to read some early performance benchmarks which compare crimson-osd vs legacy-osd, but could not find any. So eventually decided to do my own micro benchmarks in order to test transport together with PG layer, avoiding any storage costs completely (no reason to test memcpy of memstore which is the only available
objectstore for crimson). At least recalling all these ad brochures
of seastar which should bring performance on another level by doing preemption in userspace, the difference should be already there and visible in numbers.
And yes I'm aware that crimson is in development, but if basic functionality is already supported (like write path), then I can squeeze some numbers.
For all testing loads I run original rbd.fio, taken from fio/examples/, of course changing only block size. Since this is a micro benchmark I run only 1 osd cluster.
[global]
ioengine=rbd
clientname=admin
pool=rbd
rbdname=fio_test
rw=randwrite
#bs=4k
[rbd_iodepth32]
iodepth=32
-- Part 1, turn MemStore and cyan_store into null block
Testing memcpy is not interesting so in order to run any memstore with 'memstore_debug_omit_block_device_write=true' option set and skip all writes I have to do a small tweak in order to start osd, namely I still need to pass small writes and omit big ones which are sent by the client, something as the following:
- if (len > 0 && !local_conf()->memstore_debug_omit_block_device_write) { +
+ if (len > 0 &&
+ (!local_conf()->memstore_debug_omit_block_device_write ||
+ // We still want cluster meta-data to be saved, so pass only small
+ // writes, expecting user writes will be >= 4k.
+ len < 4096)) {*** BTW at the bottom you can find the whole patch with all debug
modifications made to deliver these numbers.
# legacy-osd, MemStore
MON=1 MDS=0 OSD=1 MGR=1 ../src/vstart.sh --memstore -n \
-o 'memstore_debug_omit_block_device_write=true'
4k IOPS=42.7k, BW=167MiB/s, Lat=749.18usec 8k IOPS=40.2k, BW=314MiB/s, Lat=795.03usec 16k IOPS=37.6k, BW=588MiB/s, Lat=849.12usec 32k IOPS=32.0k, BW=1000MiB/s, Lat=998.56usec 64k IOPS=25.5k, BW=1594MiB/s, Lat=1253.99usec 128k IOPS=17.5k, BW=2188MiB/s, Lat=1826.54usec 256k IOPS=10.1k, BW=2531MiB/s, Lat=3157.33usec 512k IOPS=5252, BW=2626MiB/s, Lat=6071.37usec 1m IOPS=2656, BW=2656MiB/s, Lat=12029.65usec
# crimson-osd, cyan_store
MON=1 MDS=0 OSD=1 MGR=1 ../src/vstart.sh --crimson --memstore -n \
-o 'memstore_debug_omit_block_device_write=true'
4k IOPS=40.2k, BW=157MiB/s, Lat=796.07usec 8k IOPS=37.1k, BW=290MiB/s, Lat=861.51usec 16k IOPS=32.9k, BW=514MiB/s, Lat=970.99usec 32k IOPS=26.1k, BW=815MiB/s, Lat=1225.78usec 64k IOPS=21.3k, BW=1333MiB/s, Lat=1498.92usec 128k IOPS=14.4k, BW=1795MiB/s, Lat=2227.07usec 256k IOPS=6143, BW=1536MiB/s, Lat=5203.70usec 512k IOPS=3776, BW=1888MiB/s, Lat=8464.79usec 1m IOPS=1866, BW=1867MiB/s, Lat=17126.36usec
First thing that catches my eye is that for small blocks there is no big difference at all, but as the block increases, crimsons iops starts to decline. Can it be the transport issue? Can be tested as well.
-- Part 2, complete writes immediately, even not leaving the transport
Would be great to avoid PG logic costs, exactly like we did for objectstore, i.e. the following question can be asked "how fast we can handle writes and complete them immediately from the transport callback and measure socket read/write costs?". I introduced new option 'osd_immediate_completions' and handle it directly from 'OSD::ms_[fast_]dispatch' function replying with success just immediately (for details see patch at the bottom).
# legacy-osd
MON=1 MDS=0 OSD=1 MGR=1 ../src/vstart.sh --memstore -n \
-o 'osd_immediate_completions=true'
4k IOPS=59.2k, BW=231MiB/s, Lat=539.68usec 8k IOPS=55.1k, BW=430MiB/s, Lat=580.44usec 16k IOPS=50.5k, BW=789MiB/s, Lat=633.03usec 32k IOPS=44.6k, BW=1394MiB/s, Lat=716.74usec 64k IOPS=33.5k, BW=2093MiB/s, Lat=954.60usec 128k IOPS=20.8k, BW=2604MiB/s, Lat=1535.01usec 256k IOPS=10.6k, BW=2642MiB/s, Lat=3026.19usec 512k IOPS=5400, BW=2700MiB/s, Lat=5920.86usec 1m IOPS=2549, BW=2550MiB/s, Lat=12539.40usec
# crimson-osd
MON=1 MDS=0 OSD=1 MGR=1 ../src/vstart.sh --crimson --memstore -n \
-o 'osd_immediate_completions=true'
4k IOPS=60.2k, BW=235MiB/s, Lat=530.95usec 8k IOPS=52.0k, BW=407MiB/s, Lat=614.21usec 16k IOPS=47.1k, BW=736MiB/s, Lat=678.41usec 32k IOPS=37.8k, BW=1180MiB/s, Lat=846.75usec 64k IOPS=26.6k, BW=1660MiB/s, Lat=1203.51usec 128k IOPS=15.5k, BW=1936MiB/s, Lat=2064.12usec 256k IOPS=7506, BW=1877MiB/s, Lat=4259.19usec 512k IOPS=3941, BW=1971MiB/s, Lat=8112.67usec 1m IOPS=1785, BW=1786MiB/s, Lat=17896.44usec
As a summary I can say that for me is quite surprising not to notice any iops improvements on crimson side (not to mention the problem with reading of big blocks). Since I run only 1 osd on one particular load I admit the artificial nature of such tests (thus called micro benchmark), but then on what cluster scale and what benchmark can I run to see some improvements of a new architecture?
Roman
--- src/common/options.cc | 4 ++++ src/crimson/os/cyan_store.cc | 6 +++++- src/crimson/osd/ops_executer.cc | 4 ++-- src/crimson/osd/osd.cc | 20 ++++++++++++++++++++ src/os/memstore/MemStore.cc | 6 +++++- src/osd/OSD.cc | 24 ++++++++++++++++++++++++ 6 files changed, 60 insertions(+), 4 deletions(-)
src/common/options.cc +4 -0
@@ -4234,6 +4234,10 @@ std::vector<Option> get_global_options() { .set_default(false) .set_description(""), + Option("osd_immediate_completions", Option::TYPE_BOOL, Option::LEVEL_ADVANCED) + .set_default(false) + .set_description(""), + // -------------------------- // bluestore
src/crimson/os/cyan_store.cc +5 -1
@@ -463,7 +463,11 @@ int CyanStore::_write(const coll_t& cid, const ghobject_t& oid, return -ENOENT; ObjectRef o = c->get_or_create_object(oid); - if (len > 0 && !local_conf()->memstore_debug_omit_block_device_write) { + if (len > 0 && + (!local_conf()->memstore_debug_omit_block_device_write || + // We still want cluster meta-data to be saved, so pass only small + // writes, expecting user writes will be >= 4k. + len < 4096)) { const ssize_t old_size = o->get_size(); o->write(offset, bl); used_bytes += (o->get_size() - old_size);
src/crimson/osd/ops_executer.cc +2 -2
@@ -431,8 +431,8 @@ OpsExecuter::execute_osd_op(OSDOp& osd_op) default: logger().warn("unknown op {}", ceph_osd_op_name(op.op)); - throw std::runtime_error( - fmt::format("op '{}' not supported", ceph_osd_op_name(op.op))); + // Without that `fio examples/rbd.fio` hangs on exit + throw ceph::osd::operation_not_supported{}; } }
src/crimson/osd/osd.cc +20 -0
@@ -17,6 +17,7 @@ #include "messages/MOSDOp.h" #include "messages/MOSDPGLog.h" #include "messages/MOSDRepOpReply.h" +#include "messages/MOSDOpReply.h" #include "messages/MPGStats.h" #include "os/Transaction.h"
@@ -881,6 +882,25 @@ seastar::future<> OSD::committed_osd_maps(version_t first, seastar::future<> OSD::handle_osd_op(ceph::net::Connection* conn, Ref<MOSDOp> m) { + + // + // Immediately complete requests even without leaving the transport + // + if (local_conf().get_val<bool>("osd_immediate_completions")) { + m->finish_decode(); + + for (auto op : m->ops) { + if (op.op.op == CEPH_OSD_OP_WRITE && + // Complete big writes only + op.op.extent.length >= 4096) { + + auto reply = make_message<MOSDOpReply>(m.get(), 0, osdmap->get_epoch(), + CEPH_OSD_FLAG_ACK | CEPH_OSD_FLAG_ONDISK, true); + return conn->send(reply); + } + } + } + shard_services.start_operation<ClientRequest>( *this, conn->get_shared(),
src/os/memstore/MemStore.cc +5 -1
@@ -1047,7 +1047,11 @@ int MemStore::_write(const coll_t& cid, const ghobject_t& oid, return -ENOENT; ObjectRef o = c->get_or_create_object(oid); - if (len > 0 && !cct->_conf->memstore_debug_omit_block_device_write) { + if (len > 0 && + (!cct->_conf->memstore_debug_omit_block_device_write || + // We still want cluster meta-data to be saved, so pass only small + // writes, expecting user writes will be bigger than 4k. + len < 4096)) { const ssize_t old_size = o->get_size(); o->write(offset, bl); used_bytes += (o->get_size() - old_size);
src/osd/OSD.cc +24 -0
@@ -7223,6 +7223,30 @@ void OSD::ms_fast_dispatch(Message *m) return; } + // + // Immediately complete requests even without leaving the transport + // + if (g_conf().get_val<bool>("osd_immediate_completions") && + m->get_type() == CEPH_MSG_OSD_OP) { + MOSDOp *osdop = static_cast<MOSDOp*>(m); + + osdop->finish_decode(); + + for (auto op : osdop->ops) { + if (op.op.op == CEPH_OSD_OP_WRITE && + // Complete big writes only + op.op.extent.length >= 4096) { + MOSDOpReply *reply; + + reply = new MOSDOpReply(osdop, 0, osdmap->get_epoch(), + CEPH_OSD_FLAG_ACK | CEPH_OSD_FLAG_ONDISK, true); + osdop->get_connection()->send_message(reply); + m->put(); + return; + } + } + } + // peering event? switch (m->get_type()) { case CEPH_MSG_PING:
I watched some of their crimson osd mettings on youtube and they discussed something similar... however I thought they also said that crimson-osd eats less CPU cores during that test. Did it eat less CPU in your test?
Quoted 2 lines · On 2020-01-09 14:58, [email protected] wrote:
I watched some of their crimson osd mettings on youtube and they discussed something similar...
Could you please share the link?
Quoted 3 lines
however I thought they also said that
crimson-osd eats less CPU cores during that test. Did it eat less CPU in your test?
Hm, I can't prove even that. So here is the output of pidstat while rbd.fio is running, 4k block only:
legacy-osd
[roman@dell ~]$ pidstat 1 -p 109930
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)
03:51:49 PM UID PID %usr %system %guest %wait %CPU CPU Command 03:51:51 PM 1000 109930 14.00 8.00 0.00 0.00 22.00 1 ceph-osd 03:51:52 PM 1000 109930 40.00 19.00 0.00 0.00 59.00 1 ceph-osd 03:51:53 PM 1000 109930 44.00 17.00 0.00 0.00 61.00 1 ceph-osd 03:51:54 PM 1000 109930 40.00 20.00 0.00 0.00 60.00 1 ceph-osd 03:51:55 PM 1000 109930 39.00 18.00 0.00 0.00 57.00 1 ceph-osd 03:51:56 PM 1000 109930 41.00 20.00 0.00 0.00 61.00 1 ceph-osd 03:51:57 PM 1000 109930 41.00 15.00 0.00 0.00 56.00 1 ceph-osd 03:51:58 PM 1000 109930 42.00 16.00 0.00 0.00 58.00 1 ceph-osd 03:51:59 PM 1000 109930 42.00 15.00 0.00 0.00 57.00 1 ceph-osd 03:52:00 PM 1000 109930 43.00 15.00 0.00 0.00 58.00 1 ceph-osd 03:52:01 PM 1000 109930 24.00 12.00 0.00 0.00 36.00 1 ceph-osd
crimson-osd
pidstat 1 -p 108141
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)
03:47:50 PM UID PID %usr %system %guest %wait %CPU CPU Command 03:47:55 PM 1000 108141 67.00 11.00 0.00 0.00 78.00 0 crimson-osd 03:47:56 PM 1000 108141 79.00 12.00 0.00 0.00 91.00 0 crimson-osd 03:47:57 PM 1000 108141 81.00 9.00 0.00 0.00 90.00 0 crimson-osd 03:47:58 PM 1000 108141 78.00 12.00 0.00 0.00 90.00 0 crimson-osd 03:47:59 PM 1000 108141 78.00 12.00 0.00 1.00 90.00 0 crimson-osd 03:48:00 PM 1000 108141 78.00 13.00 0.00 0.00 91.00 0 crimson-osd 03:48:01 PM 1000 108141 79.00 13.00 0.00 0.00 92.00 0 crimson-osd 03:48:02 PM 1000 108141 78.00 12.00 0.00 0.00 90.00 0 crimson-osd 03:48:03 PM 1000 108141 77.00 11.00 0.00 0.00 88.00 0 crimson-osd 03:48:04 PM 1000 108141 79.00 12.00 0.00 1.00 91.00 0 crimson-osd
--
Roman
Quoted 1 line
Could you please share the link?
It was here https://www.youtube.com/channel/UCno-Fry25FJ7B4RycCxOtfw/videos but I'm not sure about what video it was.
Quoted 2 lines
Hm, I can't prove even that. So here is the output of pidstat while rbd.fio is running, 4k block only:
Yeah... funny :)
+ Radek, Sam, in case they are interested.
Quoted 89 lines · Roman Penyaev
Subject: crimson-osd vs legacy-osd: should the perf difference be already noticeable?
Hi folks,
I was curios to read some early performance benchmarks which compare crimson-osd vs legacy-osd, but could not find any. So eventually decided to do my own micro benchmarks in order to test transport together with PG layer, avoiding any storage costs completely (no reason to test memcpy of memstore which is the only available
objectstore for crimson). At least recalling all these ad brochures
of seastar which should bring performance on another level by doing preemption in userspace, the difference should be already there and visible in numbers.And yes I'm aware that crimson is in development, but if basic functionality is already supported (like write path), then I can squeeze some numbers.
For all testing loads I run original rbd.fio, taken from fio/examples/, of course changing only block size. Since this is a micro benchmark I run only 1 osd cluster.
[global] ioengine=rbd clientname=admin pool=rbd rbdname=fio_test rw=randwrite #bs=4k [rbd_iodepth32] iodepth=32-- Part 1, turn MemStore and
cyan_storeinto null blockTesting memcpy is not interesting so in order to run any memstore with 'memstore_debug_omit_block_device_write=true' option set and skip all writes I have to do a small tweak in order to start osd, namely I still need to pass small writes and omit big ones which are sent by the client,
something as the following:- if (len > 0 && !local_conf()->memstore_debug_omit_block_device_write) {
src/crimson/os/cyan_store.cc +4
-0+ + if (len > 0 && + (!local_conf()->memstore_debug_omit_block_device_write || + // We still want cluster meta-data to be saved, so pass onlysmall
src/crimson/os/cyan_store.cc +2
-0+ // writes, expecting user writes will be >= 4k. + len < 4096)) {*** BTW at the bottom you can find the whole patch with all debug
modifications made to deliver these numbers.# legacy-osd, MemStore
MON=1 MDS=0 OSD=1 MGR=1
../src/vstart.sh--memstore -n \
-o 'memstore_debug_omit_block_device_write=true'4k IOPS=42.7k, BW=167MiB/s, Lat=749.18usec 8k IOPS=40.2k, BW=314MiB/s, Lat=795.03usec 16k IOPS=37.6k, BW=588MiB/s, Lat=849.12usec 32k IOPS=32.0k, BW=1000MiB/s, Lat=998.56usec 64k IOPS=25.5k, BW=1594MiB/s, Lat=1253.99usec 128k IOPS=17.5k, BW=2188MiB/s, Lat=1826.54usec 256k IOPS=10.1k, BW=2531MiB/s, Lat=3157.33usec 512k IOPS=5252, BW=2626MiB/s, Lat=6071.37usec1m IOPS=2656, BW=2656MiB/s, Lat=12029.65usec
# crimson-osd,
cyan_storeMON=1 MDS=0 OSD=1 MGR=1
../src/vstart.sh--crimson --memstore -n \
-o 'memstore_debug_omit_block_device_write=true'4k IOPS=40.2k, BW=157MiB/s, Lat=796.07usec 8k IOPS=37.1k, BW=290MiB/s, Lat=861.51usec 16k IOPS=32.9k, BW=514MiB/s, Lat=970.99usec 32k IOPS=26.1k, BW=815MiB/s, Lat=1225.78usec 64k IOPS=21.3k, BW=1333MiB/s, Lat=1498.92usec 128k IOPS=14.4k, BW=1795MiB/s, Lat=2227.07usec 256k IOPS=6143, BW=1536MiB/s, Lat=5203.70usec 512k IOPS=3776, BW=1888MiB/s, Lat=8464.79usec
Quoted 5 lines
1m IOPS=1866, BW=1867MiB/s, Lat=17126.36usec
First thing that catches my eye is that for small blocks there is no big difference at all, but as the block increases, crimsons iops starts to
that's also our findings. and it's expected. as async messenger uses the same reactor model as seastar does. actually its original implementation was adapted from seastar's socket stream implementation.
Quoted 1 line
decline. Can it be the transport issue? Can be tested as well.
because seastar's socket facility reads from the wire with 4K chunk size, while classic OSD's async messenger reads the payload with the size suggested by the header. so when it comes to larger block size, it takes crimson-osd multiple syscalls and memcpy calls to read the request from wire, that's why classic OSD wins in this case.
Quoted 47 lines
-- Part 2, complete writes immediately, even not leaving the transport
Would be great to avoid PG logic costs, exactly like we did for objectstore,
i.e. the following question can be asked "how fast we can handle writes and
complete them immediately from the transport callback and measure socket read/write costs?". I introduced new option 'osd_immediate_completions' and handle it directly from 'OSD::ms_[fast_]dispatch' function replying with
success just immediately (for details see patch at the bottom).# legacy-osdMON=1 MDS=0 OSD=1 MGR=1
../src/vstart.sh--memstore -n \
-o 'osd_immediate_completions=true'4k IOPS=59.2k, BW=231MiB/s, Lat=539.68usec 8k IOPS=55.1k, BW=430MiB/s, Lat=580.44usec 16k IOPS=50.5k, BW=789MiB/s, Lat=633.03usec 32k IOPS=44.6k, BW=1394MiB/s, Lat=716.74usec 64k IOPS=33.5k, BW=2093MiB/s, Lat=954.60usec 128k IOPS=20.8k, BW=2604MiB/s, Lat=1535.01usec 256k IOPS=10.6k, BW=2642MiB/s, Lat=3026.19usec 512k IOPS=5400, BW=2700MiB/s, Lat=5920.86usec1m IOPS=2549, BW=2550MiB/s, Lat=12539.40usec
# crimson-osdMON=1 MDS=0 OSD=1 MGR=1
../src/vstart.sh--crimson --memstore -n \
-o 'osd_immediate_completions=true'4k IOPS=60.2k, BW=235MiB/s, Lat=530.95usec 8k IOPS=52.0k, BW=407MiB/s, Lat=614.21usec 16k IOPS=47.1k, BW=736MiB/s, Lat=678.41usec 32k IOPS=37.8k, BW=1180MiB/s, Lat=846.75usec 64k IOPS=26.6k, BW=1660MiB/s, Lat=1203.51usec 128k IOPS=15.5k, BW=1936MiB/s, Lat=2064.12usec 256k IOPS=7506, BW=1877MiB/s, Lat=4259.19usec 512k IOPS=3941, BW=1971MiB/s, Lat=8112.67usec1m IOPS=1785, BW=1786MiB/s, Lat=17896.44usec
Quoted 9 lines
As a summary I can say that for me is quite surprising not to notice any iops improvements on crimson side (not to mention the problem with reading
of big blocks). Since I run only 1 osd on one particular load I admit the
artificial nature of such tests (thus called micro benchmark), but then on what cluster scale and what benchmark can I run to see some improvements
of a new architecture?
have you tried to use multiple fio clients to saturate CPU capacity of OSD nodes?
Quoted 161 lines
Roman
--- src/common/options.cc | 4 ++++ src/crimson/os/cyan_store.cc | 6 +++++- src/crimson/osd/ops_executer.cc | 4 ++-- src/crimson/osd/osd.cc | 20 ++++++++++++++++++++ src/os/memstore/MemStore.cc | 6 +++++- src/osd/OSD.cc | 24 ++++++++++++++++++++++++ 6 files changed, 60 insertions(+), 4 deletions(-)src/common/options.cc +4
-0@@ -4234,6 +4234,10 @@ std::vector<Option> get_global_options() { .set_default(false) .set_description(""), + Option("osd_immediate_completions", Option::TYPE_BOOL, Option::LEVEL_ADVANCED) + .set_default(false) + .set_description(""), + // -------------------------- // bluestoresrc/crimson/os/cyan_store.cc +3
-1@@ -463,7 +463,11 @@ int CyanStore::_write(const coll_t& cid, const ghobject_t& oid, return -ENOENT; ObjectRef o = c->get_or_create_object(oid); - if (len > 0 && !local_conf()->memstore_debug_omit_block_device_write) { + if (len > 0 && + (!local_conf()->memstore_debug_omit_block_device_write || + // We still want cluster meta-data to be saved, so pass onlysmall
src/crimson/os/cyan_store.cc +2
-0+ // writes, expecting user writes will be >= 4k. + len < 4096)) { const ssize_t old_size = o->get_size(); o->write(offset, bl); used_bytes += (o->get_size() - old_size);src/crimson/osd/ops_executer.cc +2
-2@@ -431,8 +431,8 @@ OpsExecuter::execute_osd_op(OSDOp& osd_op) default: logger().warn("unknown op {}", ceph_osd_op_name(op.op)); - throw std::runtime_error( - fmt::format("op '{}' not supported", ceph_osd_op_name(op.op))); + // Without that `fio examples/rbd.fio` hangs on exit + throw ceph::osd::operation_not_supported{}; } }src/crimson/osd/osd.cc +20
-0@@ -17,6 +17,7 @@ #include "messages/MOSDOp.h" #include "messages/MOSDPGLog.h" #include "messages/MOSDRepOpReply.h" +#include "messages/MOSDOpReply.h" #include "messages/MPGStats.h" #include "os/Transaction.h"@@ -881,6 +882,25 @@ seastar::future<> OSD::committed_osd_maps(version_t first, seastar::future<> OSD::handle_osd_op(ceph::net::Connection* conn, Ref<MOSDOp> m) { + + // + // Immediately complete requests even without leaving the transport + // + if (local_conf().get_val<bool>("osd_immediate_completions")) { + m->finish_decode(); + + for (auto op : m->ops) { + if (op.op.op == CEPH_OSD_OP_WRITE && + // Complete big writes only + op.op.extent.length >= 4096) { + + auto reply = make_message<MOSDOpReply>(m.get(), 0, osdmap->get_epoch(), + CEPH_OSD_FLAG_ACK | CEPH_OSD_FLAG_ONDISK, true); + return conn->send(reply); + } + } + } +shard_services.start_operation<ClientRequest>( *this, conn->get_shared(),src/os/memstore/MemStore.cc +3
-1@@ -1047,7 +1047,11 @@ int MemStore::_write(const coll_t& cid, const ghobject_t& oid, return -ENOENT; ObjectRef o = c->get_or_create_object(oid); - if (len > 0 && !cct->_conf->memstore_debug_omit_block_device_write) { + if (len > 0 && + (!cct->_conf->memstore_debug_omit_block_device_write || + // We still want cluster meta-data to be saved, so pass onlysmall
src/os/memstore/MemStore.cc +2
-0+ // writes, expecting user writes will be bigger than 4k. + len < 4096)) { const ssize_t old_size = o->get_size(); o->write(offset, bl); used_bytes += (o->get_size() - old_size);src/osd/OSD.cc +24
-0@@ -7223,6 +7223,30 @@ void OSD::ms_fast_dispatch(Message *m) return; } + // + // Immediately complete requests even without leaving the transport + // + if (g_conf().get_val<bool>("osd_immediate_completions") && + m->get_type() == CEPH_MSG_OSD_OP) { + MOSDOp *osdop = static_cast<MOSDOp*>(m); + + osdop->finish_decode(); + + for (auto op : osdop->ops) { + if (op.op.op == CEPH_OSD_OP_WRITE && + // Complete big writes only + op.op.extent.length >= 4096) { + MOSDOpReply *reply; + + reply = new MOSDOpReply(osdop, 0, osdmap->get_epoch(), + CEPH_OSD_FLAG_ACK | CEPH_OSD_FLAG_ONDISK, true); + osdop->get_connection()->send_message(reply); + m->put(); + return; + } + } + } + // peering event? switch (m->get_type()) {case
CEPH_MSG_PING:
Signature · 2 lines
Regards Kefu Chai
On 2020-01-10 17:18, kefu chai wrote:
[skip]
Quoted 8 lines
Quoted 3 lines
First thing that catches my eye is that for small blocks there is no big difference at all, but as the block increases, crimsons iops starts to
that's also our findings. and it's expected. as async messenger uses the same reactor model as seastar does. actually its original implementation was adapted from seastar's socket stream implementation.
Hm, regardless of model messenger should not be a bottleneck. Take a look on the results of fio_ceph_messenger load (runs pure messenger), I can squeeze IOPS=89.8k, BW=351MiB/s on 4k block size, iodepth=32. (also good example https://github.com/ceph/ceph/pull/26932 , almost ~200k)
With PG layer (memstore_debug_omit_block_device_write=true option) I can reach 40k iops max. Without PG layer (immediate completion from the transport callback, osd_immediate_completions=true) I get almost 60k.
Seems that here starts playing costs on client side and these costs prevail.
Quoted 8 lines
Quoted 2 lines
decline. Can it be the transport issue? Can be tested as well.
because seastar's socket facility reads from the wire with 4K chunk size, while classic OSD's async messenger reads the payload with the size suggested by the header. so when it comes to larger block size, it takes crimson-osd multiple syscalls and memcpy calls to read the request from wire, that's why classic OSD wins in this case.
Do you plan to fix that?
Quoted 2 lines
have you tried to use multiple fio clients to saturate CPU capacity of OSD nodes?
Not yet. But regarding CPU I have these numbers:
output of pidstat while rbd.fio is running, 4k block only:
legacy-osd
[roman@dell ~]$ pidstat 1 -p 109930
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)
03:51:49 PM UID PID %usr %system %guest %wait %CPU CPU Command 03:51:51 PM 1000 109930 14.00 8.00 0.00 0.00 22.00 1 ceph-osd 03:51:52 PM 1000 109930 40.00 19.00 0.00 0.00 59.00 1 ceph-osd 03:51:53 PM 1000 109930 44.00 17.00 0.00 0.00 61.00 1 ceph-osd 03:51:54 PM 1000 109930 40.00 20.00 0.00 0.00 60.00 1 ceph-osd 03:51:55 PM 1000 109930 39.00 18.00 0.00 0.00 57.00 1 ceph-osd 03:51:56 PM 1000 109930 41.00 20.00 0.00 0.00 61.00 1 ceph-osd 03:51:57 PM 1000 109930 41.00 15.00 0.00 0.00 56.00 1 ceph-osd 03:51:58 PM 1000 109930 42.00 16.00 0.00 0.00 58.00 1 ceph-osd 03:51:59 PM 1000 109930 42.00 15.00 0.00 0.00 57.00 1 ceph-osd 03:52:00 PM 1000 109930 43.00 15.00 0.00 0.00 58.00 1 ceph-osd 03:52:01 PM 1000 109930 24.00 12.00 0.00 0.00 36.00 1 ceph-osd
crimson-osd
[roman@dell ~]$ pidstat 1 -p 108141
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)
03:47:50 PM UID PID %usr %system %guest %wait %CPU CPU Command 03:47:55 PM 1000 108141 67.00 11.00 0.00 0.00 78.00 0 crimson-osd 03:47:56 PM 1000 108141 79.00 12.00 0.00 0.00 91.00 0 crimson-osd 03:47:57 PM 1000 108141 81.00 9.00 0.00 0.00 90.00 0 crimson-osd 03:47:58 PM 1000 108141 78.00 12.00 0.00 0.00 90.00 0 crimson-osd 03:47:59 PM 1000 108141 78.00 12.00 0.00 1.00 90.00 0 crimson-osd 03:48:00 PM 1000 108141 78.00 13.00 0.00 0.00 91.00 0 crimson-osd 03:48:01 PM 1000 108141 79.00 13.00 0.00 0.00 92.00 0 crimson-osd 03:48:02 PM 1000 108141 78.00 12.00 0.00 0.00 90.00 0 crimson-osd 03:48:03 PM 1000 108141 77.00 11.00 0.00 0.00 88.00 0 crimson-osd 03:48:04 PM 1000 108141 79.00 12.00 0.00 1.00 91.00 0 crimson-osd
Seems quite saturated, almost twice more than legacy-osd. Did you see something similar?
--
Roman
Quoted 117 lines
-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Roman Penyaev
Sent: Friday, January 10, 2020 10:54 AM
To: kefu chai <[email protected]>
Cc: Radoslaw Zarzynski <[email protected]>; Samuel Just <[email protected]>; The Esoteric Order of the Squid Cybernetic <ceph- [email protected]>
Subject: Re: crimson-osd vs legacy-osd: should the perf difference be already noticeable?On 2020-01-10 17:18, kefu chai wrote:
[skip]
Quoted 9 lines
Quoted 4 lines
First thing that catches my eye is that for small blocks there is no big difference at all, but as the block increases, crimsons iops starts to
that's also our findings. and it's expected. as async messenger uses the same reactor model as seastar does. actually its original implementation was adapted from seastar's socket stream implementation.
Hm, regardless of model messenger should not be a bottleneck. Take a look on the results of
fio_ceph_messengerload (runs pure messenger), I can squeeze IOPS=89.8k, BW=351MiB/s on 4k block size, iodepth=32.
(also good example https://github.com/ceph/ceph/pull/26932 , almost ~200k)With PG layer (memstore_debug_omit_block_device_write=true option) I can reach 40k iops max. Without PG layer (immediate completion from the transport callback, osd_immediate_completions=true) I get almost 60k.
Seems that here starts playing costs on client side and these costs prevail.
Quoted 8 lines
Quoted 2 lines
decline. Can it be the transport issue? Can be tested as well.
because seastar's socket facility reads from the wire with 4K chunk size, while classic OSD's async messenger reads the payload with the size suggested by the header. so when it comes to larger block size, it takes crimson-osd multiple syscalls and memcpy calls to read the request from wire, that's why classic OSD wins in this case.
Do you plan to fix that?
Quoted 2 lines
have you tried to use multiple fio clients to saturate CPU capacity of OSD nodes?
Not yet. But regarding CPU I have these numbers:
output of pidstat while rbd.fio is running, 4k block only:
legacy-osd
[roman@dell ~]$ pidstat 1 -p 109930
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)03:51:49 PM UID PID %usr %system %guest %wait %CPU
CPU Command
03:51:51 PM 1000 109930 14.00 8.00 0.00 0.00 22.00
1 ceph-osd
03:51:52 PM 1000 109930 40.00 19.00 0.00 0.00 59.00
1 ceph-osd
03:51:53 PM 1000 109930 44.00 17.00 0.00 0.00 61.00
1 ceph-osd
03:51:54 PM 1000 109930 40.00 20.00 0.00 0.00 60.00
1 ceph-osd
03:51:55 PM 1000 109930 39.00 18.00 0.00 0.00 57.00
1 ceph-osd
03:51:56 PM 1000 109930 41.00 20.00 0.00 0.00 61.00
1 ceph-osd
03:51:57 PM 1000 109930 41.00 15.00 0.00 0.00 56.00
1 ceph-osd
03:51:58 PM 1000 109930 42.00 16.00 0.00 0.00 58.00
1 ceph-osd
03:51:59 PM 1000 109930 42.00 15.00 0.00 0.00 57.00
1 ceph-osd
03:52:00 PM 1000 109930 43.00 15.00 0.00 0.00 58.00
1 ceph-osd
03:52:01 PM 1000 109930 24.00 12.00 0.00 0.00 36.00
1 ceph-osdcrimson-osd
[roman@dell ~]$ pidstat 1 -p 108141
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)03:47:50 PM UID PID %usr %system %guest %wait %CPU
CPU Command
03:47:55 PM 1000 108141 67.00 11.00 0.00 0.00 78.00
0 crimson-osd
03:47:56 PM 1000 108141 79.00 12.00 0.00 0.00 91.00
0 crimson-osd
03:47:57 PM 1000 108141 81.00 9.00 0.00 0.00 90.00
0 crimson-osd
03:47:58 PM 1000 108141 78.00 12.00 0.00 0.00 90.00
0 crimson-osd
03:47:59 PM 1000 108141 78.00 12.00 0.00 1.00 90.00
0 crimson-osd
03:48:00 PM 1000 108141 78.00 13.00 0.00 0.00 91.00
0 crimson-osd
03:48:01 PM 1000 108141 79.00 13.00 0.00 0.00 92.00
0 crimson-osd
03:48:02 PM 1000 108141 78.00 12.00 0.00 0.00 90.00
0 crimson-osd
03:48:03 PM 1000 108141 77.00 11.00 0.00 0.00 88.00
0 crimson-osd
03:48:04 PM 1000 108141 79.00 12.00 0.00 1.00 91.00
0 crimson-osd
Quoted 2 lines
Seems quite saturated, almost twice more than legacy-osd. Did you see something similar?
Crimson-osd (seastar) use epoll, by default, it will use more cpu capacity,(you can change epoll mode setting to reduce it), add Ma, Jianpeng in the thread since he did more study on it.
BTW, by default crimson-osd is one thread, and legacy ceph-osd (3 threads for async messenger, 2x8 threads for osd (SDD), finisher thread etc,) ,so by default setting, it is 1 thread compare to over 10 threads work, it is expected crimson-osd not show obvious difference. you can change the default thread number for legacy ceph-osd(such as thread=1 for each layer to see more difference.) BTW, please use release build to do test.
Crimson-osd is aysnc model, if workload is very light, can't take more advantage of it.
Quoted 3 lines
--
Roman
Quoted 117 lines · Chunmei
Quoted 117 lines
-----Original Message-----
From: [email protected] <[email protected]> On Behalf Of Roman Penyaev
Sent: Friday, January 10, 2020 10:54 AM
To: kefu chai <[email protected]>
Cc: Radoslaw Zarzynski <[email protected]>; Samuel Just <[email protected]>; The Esoteric Order of the Squid Cybernetic <ceph- [email protected]>
Subject: Re: crimson-osd vs legacy-osd: should the perf difference be already noticeable?On 2020-01-10 17:18, kefu chai wrote:
[skip]
Quoted 9 lines
Quoted 4 lines
First thing that catches my eye is that for small blocks there is no big difference at all, but as the block increases, crimsons iops starts to
that's also our findings. and it's expected. as async messenger uses the same reactor model as seastar does. actually its original implementation was adapted from seastar's socket stream implementation.
Hm, regardless of model messenger should not be a bottleneck. Take a look on the results of
fio_ceph_messengerload (runs pure messenger), I can squeeze IOPS=89.8k, BW=351MiB/s on 4k block size, iodepth=32.
(also good example https://github.com/ceph/ceph/pull/26932 , almost ~200k)With PG layer (memstore_debug_omit_block_device_write=true option) I can reach 40k iops max. Without PG layer (immediate completion from the transport callback, osd_immediate_completions=true) I get almost 60k.
Seems that here starts playing costs on client side and these costs prevail.
Quoted 8 lines
Quoted 2 lines
decline. Can it be the transport issue? Can be tested as well.
because seastar's socket facility reads from the wire with 4K chunk size, while classic OSD's async messenger reads the payload with the size suggested by the header. so when it comes to larger block size, it takes crimson-osd multiple syscalls and memcpy calls to read the request from wire, that's why classic OSD wins in this case.
Do you plan to fix that?
Quoted 2 lines
have you tried to use multiple fio clients to saturate CPU capacity of OSD nodes?
Not yet. But regarding CPU I have these numbers:
output of pidstat while rbd.fio is running, 4k block only:
legacy-osd
[roman@dell ~]$ pidstat 1 -p 109930
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)03:51:49 PM UID PID %usr %system %guest %wait %CPU
CPU Command
03:51:51 PM 1000 109930 14.00 8.00 0.00 0.00 22.00
1 ceph-osd
03:51:52 PM 1000 109930 40.00 19.00 0.00 0.00 59.00
1 ceph-osd
03:51:53 PM 1000 109930 44.00 17.00 0.00 0.00 61.00
1 ceph-osd
03:51:54 PM 1000 109930 40.00 20.00 0.00 0.00 60.00
1 ceph-osd
03:51:55 PM 1000 109930 39.00 18.00 0.00 0.00 57.00
1 ceph-osd
03:51:56 PM 1000 109930 41.00 20.00 0.00 0.00 61.00
1 ceph-osd
03:51:57 PM 1000 109930 41.00 15.00 0.00 0.00 56.00
1 ceph-osd
03:51:58 PM 1000 109930 42.00 16.00 0.00 0.00 58.00
1 ceph-osd
03:51:59 PM 1000 109930 42.00 15.00 0.00 0.00 57.00
1 ceph-osd
03:52:00 PM 1000 109930 43.00 15.00 0.00 0.00 58.00
1 ceph-osd
03:52:01 PM 1000 109930 24.00 12.00 0.00 0.00 36.00
1 ceph-osdcrimson-osd
[roman@dell ~]$ pidstat 1 -p 108141
Linux 5.3.13-arch1-1 (dell) 01/09/2020 _x86_64_ (8 CPU)03:47:50 PM UID PID %usr %system %guest %wait %CPU
CPU Command
03:47:55 PM 1000 108141 67.00 11.00 0.00 0.00 78.00
0 crimson-osd
03:47:56 PM 1000 108141 79.00 12.00 0.00 0.00 91.00
0 crimson-osd
03:47:57 PM 1000 108141 81.00 9.00 0.00 0.00 90.00
0 crimson-osd
03:47:58 PM 1000 108141 78.00 12.00 0.00 0.00 90.00
0 crimson-osd
03:47:59 PM 1000 108141 78.00 12.00 0.00 1.00 90.00
0 crimson-osd
03:48:00 PM 1000 108141 78.00 13.00 0.00 0.00 91.00
0 crimson-osd
03:48:01 PM 1000 108141 79.00 13.00 0.00 0.00 92.00
0 crimson-osd
03:48:02 PM 1000 108141 78.00 12.00 0.00 0.00 90.00
0 crimson-osd
03:48:03 PM 1000 108141 77.00 11.00 0.00 0.00 88.00
0 crimson-osd
03:48:04 PM 1000 108141 79.00 12.00 0.00 1.00 91.00
0 crimson-osd
Quoted 10 lines
Quoted 2 lines
Seems quite saturated, almost twice more than legacy-osd. Did you see something similar?
Crimson-osd (seastar) use epoll, by default, it will use more cpu capacity,(you can change epoll mode setting to reduce it), add Ma, Jianpeng in the thread since he did more study on it.
BTW, by default crimson-osd is one thread, and legacy ceph-osd (3 threads for async messenger, 2x8 threads for osd (SDD), finisher thread etc,) ,so by default setting, it is 1 thread compare to over 10 threads work, it is expected crimson-osd not show obvious difference. you can change the default thread number for legacy ceph-osd(such as thread=1 for each layer to see more difference.) BTW, please use release build to do test.
Crimson-osd is aysnc model, if workload is very light, can't take more advantage of it.Quoted 3 lines
--
Roman
FWIW I can drive the classical OSD pretty hard and get around 70-80K IOPS out of a single OSD, but as Kefu says above it will consume a larger number of cores. I do think per-OSD throughput is still important to look at, but the per-OSD efficiency numbers as Radek has been testing (I gathered some for classical OSD a while back for him) are probably going to be more important overall.
Mark