Hello, list,

I have found one interesting issue.
I use 4 disk node with NBD, and the concentrator distributes the load equal thanks to 32KB chunksize RAID0 inside.

At this time i am working on the system upgrade, and found one interesting issue, and possibly one bottleneck on the system.

The concentrator shows this with iostat -d -k -x 10:
(I have marked the interesting parts with [ ])

Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s rkB/s wkB/s
avgrq-sz avgqu-sz await svctm %util

nbd0        54.15   0.00 45.85  0.00 6169.83    0.00  3084.92     0.00
134.55     1.43   31.11   7.04  32.27           <--node-1
nbd1        58.24   0.00 44.06  0.00 6205.79    0.00  [3102.90]     0.00
140.86   516.74 11490.79  22.70 100.00 <--node-2
nbd2        55.84   0.00 44.76  0.00 6159.44    0.00  3079.72     0.00
137.62     1.51   33.73   6.88  30.77
nbd3        55.34   0.00 45.05  0.00 6169.03    0.00  3084.52     0.00
136.92     1.07   23.79   5.72  25.77

md31 0.00 0.00 401.70 0.10 24607.39 1.00 12303.70 0.50
61.25 0.00 0.00 0.00 0.00

The "old" node-1 shows this:
Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s rkB/s wkB/s
avgrq-sz avgqu-sz await svctm %util
hda 140.26 0.80 9.19 3.50 1195.60 34.37 597.80 17.18
96.94 0.20 15.43 11.81 14.99
hdc 133.37 0.00 8.89 3.30 1138.06 26.37 569.03 13.19
95.54 0.17 13.85 11.15 13.59
hde 142.76 1.40 13.99 3.90 1253.95 42.36 626.97 21.18
72.49 0.29 16.31 10.00 17.88
hdi 136.56 0.20 13.19 3.10 1197.20 26.37 598.60 13.19
75.14 0.33 20.12 12.82 20.88
hdk 134.07 0.30 13.89 3.40 1183.62 29.57 591.81 14.79
70.20 0.28 16.30 10.87 18.78
hdm 137.46 0.20 13.39 3.80 1205.99 31.97 603.00 15.98
72.05 0.38 21.98 12.67 21.78
hdo 125.07 0.10 11.69 3.20 1093.31 26.37 546.65 13.19
75.22 0.32 21.54 14.23 21.18
hdq 131.37 1.20 12.49 3.70 1150.85 39.16 575.42 19.58
73.53 0.30 18.77 12.04 19.48
hds 130.97 1.40 13.59 4.10 1155.64 43.96 577.82 21.98
67.84 0.57 32.37 14.80 26.17
sda 148.55 1.30 10.09 3.70 1269.13 39.96 634.57 19.98
94.96 0.30 21.81 14.86 20.48
sdb 131.07 0.10 9.69 3.30 1125.27 27.17 562.64 13.59
88.74 0.18 13.92 11.31 14.69
md0 0.00 0.00 1611.49 5.29 12891.91 42.36 [6445.95] 21.18
8.00 0.00 0.00 0.00 0.00

The "new" node #2 shows this:
Device: rrqm/s wrqm/s r/s w/s rsec/s wsec/s rkB/s wkB/s
avgrq-sz avgqu-sz await svctm %util

hda        1377.02   0.00 15.88  0.20 11143.26    1.60  5571.63     0.80
692.92     0.39   24.47  18.76  30.17
hdb        1406.79   0.00  8.59  0.20 11323.08    1.60  5661.54     0.80
1288.18     0.28   32.16  31.48  27.67
hde        1430.77   0.00  8.19  0.20 11511.69    1.60  5755.84     0.80
1372.00     0.27   32.74  29.17  24.48
hdf        1384.42   0.00  6.99  0.20 11130.47    1.60  5565.23     0.80
1547.67     0.40   56.94  54.86  39.46
sda        1489.11   0.00 15.08  0.20 12033.57    1.60  6016.78     0.80
787.40     0.36   23.33  14.38  21.98
sdb        1392.11   0.00 14.39  0.20 11251.95    1.60  5625.97     0.80
771.56     0.39   26.78  16.16  23.58
sdc        1468.33   3.00 14.29  0.40 11860.94   27.17  5930.47    13.59
809.52     0.37   25.24  14.97  21.98
sdd        1498.30   1.50 14.99  0.30 12106.29   14.39  6053.15     7.19
792.99     0.40   26.21  15.82  24.18
sde        1446.55   0.00 13.79  0.20 11683.52    1.60  5841.76     0.80
835.49     0.37   26.36  16.14  22.58
sdf        1510.59   0.00 13.19  0.20 12191.01    1.60  6095.50     0.80
910.81     0.39   28.96  17.39  23.28
sdg        1421.18   0.00 14.69  0.20 11486.91    1.60  5743.46     0.80
771.81     0.35   23.83  15.23  22.68

sdh 4.50 4.50 0.30 0.50 38.36 39.96 19.18 19.98
98.00 0.00 1.25 1.25 0.10
md1 0.00 0.00 15960.54 4.80 127684.32 38.36 [63842.16]
19.18 8.00 0.00 0.00 0.00 0.00

The node-1 (+3,4) have one raid-5 with chunksize 32K The new node-2 have currently raid4, chunksize 1024K

The NBD is serves only 1KB blocks. (ethernet network)

Currently to clean test, the readahead on all nodes is set to 0 on all devices, including md[0-1]!

The question is this:
The 3.1MB/s requests on concentrator how can generate 6.4MB/s read on node1 and 63.8MB/s on node2 with all readahead 0?

Does the raid 4,5 hardcoded readahead?
Or if the nbd-server fetch one kb, the raid (or another part of OS) reads the entire chunk?

Thanks,