Skip to contentSkip to conversation

[Fwd: Re: Syncing rme9652 with yamaha 01v]

Fwd: Re: Syncing rme9652 with yamaha 01v Zenaan Harkness 2 participants 2 messages Oct 10, 2002 – Oct 11, 2002

lore
Share & tools
lore
#0 lore raw

Forwarde as requested. Sorry if it gets through twice or not at all...

zen

-----Forwarded Message-----

Quoted 61 lines

From: Paul Davis <[email protected]>
To: Zenaan Harkness <[email protected]>
Cc: [email protected]
Subject: Re: [Alsa-devel] Syncing rme9652 with yamaha 01v
Date: 10 Oct 2002 09:17:04 -0400

[
please forward this response to [email protected]; i can't send mail there at this time.
]

Quoted 4 lines

I want to know how to set the sync options in the rme9652 (the manual says it "can be configured to use the following clock sources: external input signal (AutoSync), internal clock (Master), or external word clock signal (Wordclock).

all such configuration is done just like with any other ALSA device:
using the control API via one of text-based tools such as alsactl or amixer. a typical sequence with alsactl:

% alsactl -f foo store name-of-your-rme9652-card % your-favorite-editor foo
... edit file ...
% alsactl -f foo restore name-of-your-rme9652-card

while in your favorite editor, look for this block:

control.7 {
comment.access 'read write'
comment.type ENUMERATED
comment.item.0 AutoSync
comment.item.1 Master
comment.item.2 'Word Clock'
iface PCM
name 'Sync Mode'
value AutoSync
}

and change the "value" field to your preferred choice (see below).

it can be quicker to do this with amixer:

% amixer -D name-of-your-9652-card cset iface=PCM,name='Sync Mode' 'Master'

see man amixer for more details on this. i generally use alsactl myself.

Quoted 3 lines

The main problem is sync error - the desk has two options - auto, and external (ADAT) - choosing either results in ongoing sync pops and dropouts, etc.

you need the rme9652 set to "Master". repeat after me: any digital audio system must have one and only sample clock source. since the desk can't be a master (apparently), then the rme9652 must be.

Quoted 1 line

Should aconnectgui help me?

no. it has nothing to do with this - its related to use of the ALSA sequencer.

--p

Signature · 10 lines
Mr Zenaan Harkness, Manager, VIDC
Phone: +678 25 151  Fax: +678 25 178  Mobile: +678 45 179
Please respect the confidentiality of this email.



-------------------------------------------------------
This sf.net email is sponsored by:ThinkGeek
Welcome to geek heaven.
http://thinkgeek.com/sf
#1 lore raw

At 11 Oct 2002 09:16:00 +1100,

Quoted 27 lines · Zenaan Harkness

Forwarde as requested. Sorry if it gets through twice or not at all...

zen

-----Forwarded Message-----

Quoted 19 lines

From: Paul Davis <[email protected]>
To: Zenaan Harkness <[email protected]>
Cc: [email protected]
Subject: Re: [Alsa-devel] Syncing rme9652 with yamaha 01v
Date: 10 Oct 2002 09:17:04 -0400

[
please forward this response to [email protected]; i can't send mail there at this time.
]

Quoted 4 lines

I want to know how to set the sync options in the rme9652 (the manual says it "can be configured to use the following clock sources: external input signal (AutoSync), internal clock (Master), or external word clock signal (Wordclock).

all such configuration is done just like with any other ALSA device:
using the control API via one of text-based tools such as alsactl or amixer. a typical sequence with alsactl:

the latest alsamixer on cvs can change such an enum item, too.

Takashi

-------------------------------------------------------
This sf.net email is sponsored by:ThinkGeek
Welcome to geek heaven.
http://thinkgeek.com/sf