Exposing the same VG from two different disks
I've had a closer look at the vgimportclone script and I think the fix for the
lost filter is very straight forward. The errors are coming out of the final vgscan and it seems to be caused by the LVM_SYSTEM_DIR variable being set to an
empty string rather than being unset. So I made the following change and it seemed to fix the errors...
327,333c327
<
< if [[ -z ${ORIG_LVM_SYS_DIR} ]]
< then
< unset LVM_SYSTEM_DIR
< else
< LVM_SYSTEM_DIR=${ORIG_LVM_SYS_DIR}
< fi
---
Quoted 1 line
LVM_SYSTEM_DIR=${ORIG_LVM_SYS_DIR}
I'm not sure if this change causes any issues but I'd be suprised. Thanks
Liam
Quoted 72 lines
Thanks to everyone who replied. The vgimportclone worked really well and I can recommend it to anyone who is in my situation.
I have a follow up question about how the LVM filter works in the script. Should I post here or to the LVM Devel list instead?
Just in case here is the right place !!! My question is, I have multiple paths to the same disks so I have masked the individual paths (the sd devices) and just exposed the logical deives (the emcpower devices). The script loses this filter and complains about lots of duplicate PV ids as it runs through. This "problem" is purely cosmetic and doesn't seem to in anyway effect the script from working. If this is not expected behaviour and the fix is fairly straight forward I'd be more than happy to test any fix. I've had a look at trying to see where the errors are coming from but I have to admit my LVM knowledge isn't up to it.
Thanks again to everyone for their hope,
LiamQuoted 17 lines · On Fri, 2009-06-05 at 15:18 +0200, [email protected] wrote:
Quoted 16 lines
Hi,
I'm not sure if what I'm trying to do is possible or not but hopefully
someone out there can help!!I have a volume group which consists of a LUN (
/dev/emcpowerv1) in an
EMC cabinet. To backup up the disk I use EMC technology to synchronise a second LUN (/dev/emcpoweraf1) with the first, when the synchronisation is complete I then break the connection. At this point I have two identical volume groups exposed to the same host. What I would like to do is rename the second volume group and mount its logical volumes. However I can't because (understandably) LVM doesn't like having two identical volume groups so when I issue pvchange -u I get...Quoted 2 lines
Quoted 2 lines
# pvchange -u /dev/emcpoweraf1 Found duplicate PV dXiYI6nVqu8UpXO2mlaWiKKPKSBPrRbn: using
/dev/emcpowerv1Quoted 20 lines
not
/dev/emcpoweraf1Quoted 2 lines
get_pv_from_vg_by_id:vg_readfailed to read VG !/dev/emcpowerv1: write failed after 0 of 4096 at 4096: Operation notpermitted
Quoted 4 lines
pv_writewith new uuid failed for/dev/emcpowerv1. 0 physical volumes changed / 1 physical volume not changedNotice I issue the command against
/dev/emcpoweraf1but it complains aboutwriting to
/dev/emcpowerv1.Take a look at the vgimportclone script posted to the lvm-devel list last month:
http://www.redhat.com/archives/lvm-devel/2009-May/msg00130.html
Regards,
Bryn.Quoted 5 lines
_______________________________________________
linux-lvm mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/linux-lvm
read the LVM HOW-TO at http://tldp.org/HOWTO/LVM-HOWTO/_______________________________________________
linux-lvm mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/linux-lvm
read the LVM HOW-TO at http://tldp.org/HOWTO/LVM-HOWTO/
Quoted 15 lines · On Wed, Jun 17 2009 at 10:27am -0400, [email protected] <[email protected]>…
I've had a closer look at the vgimportclone script and I think the fix for the
lost filter is very straight forward. The errors are coming out of the final vgscan and it seems to be caused by theLVM_SYSTEM_DIRvariable being set to an
empty string rather than being unset. So I made the following change and it seemed to fix the errors...327,333c327
<
< if [[ -z ${ORIG_LVM_SYS_DIR} ]]
< then
< unsetLVM_SYSTEM_DIR
< else
< LVM_SYSTEM_DIR=${ORIG_LVM_SYS_DIR}
< fi
---
Quoted 3 lines
Quoted 1 line
LVM_SYSTEM_DIR=${ORIG_LVM_SYS_DIR}
I'm not sure if this change causes any issues but I'd be suprised.
Liam,
Looks good, I've committed your fix along with various other fixes to vgimportclone.
Thanks,
Mike
Quoted 8 lines
I've had a closer look at the vgimportclone script and I think the fix for the lost filter is very straight forward. The errors are coming out of the final vgscan and it seems to be caused by the
LVM_SYSTEM_DIRvariable being set to an empty string rather than being unset. So I made the following change and it seemed to fix the errors...
Cool, I'd kind of noticed this bit of weirdness but hadn't got round to actually doing anything about it :)
LVM_SYSTEM_DIR also gets reset in the cleanup function (which pointless because our changes are dropped when the script ends anyway so we might as well get rid of it, also we're using #!/bin/sh but assuming several bash-isms so this is a cleanup patch that covers both (hopefully I've figured out how to create proper patches!):
vgimportclone.sh +1 -3
@@ -1,4 +1,4 @@ -#!/bin/sh +#!/bin/bash # Copyright (C) 2009 Chris Procter All rights reserved. # Copyright (C) 2009 Red Hat, Inc. All rights reserved.
@@ -87,8 +87,6 @@ function cleanup { - #set to use old lvm.conf - LVM_SYSTEM_DIR=${ORIG_LVM_SYS_DIR} if [ $KEEP_TMP_LVM_SYSTEM_DIR -eq 1 ]; then echo "${SCRIPTNAME}: LVM_SYSTEM_DIR (${TMP_LVM_SYSTEM_DIR}) must be cleaned up manually."