Hi all,

Recently we had cluster customer where the fencing agent successfully powered off a node, but the script failed to power the node back on due to firmware changes on the fencing device.

Question is whether we should consider this a successful fence event or
does the agent have to complete everything? The primary purpose of the
fencing agent is to stop the node from participating in the cluster. In this case, that was successful. But, because the power on attempt failed, the fence agent reported failure and the cluster hung waiting for a followup action.

It would seem to me that the fence agent should report success in this case, and maybe post a warning message about the failure to power on.

Thoughts?
Kevin

#1 lore raw
Quoted 13 lines · Kevin Anderson

Hi all,

Recently we had cluster customer where the fencing agent successfully powered off a node, but the script failed to power the node back on due to firmware changes on the fencing device.

Question is whether we should consider this a successful fence event or
does the agent have to complete everything? The primary purpose of the
fencing agent is to stop the node from participating in the cluster. In this case, that was successful. But, because the power on attempt failed, the fence agent reported failure and the cluster hung waiting for a followup action.

Quoted 4 lines

It would seem to me that the fence agent should report success in this case, and maybe post a warning message about the failure to power on.

Thoughts?

Definately

#2 lore raw
Quoted 14 lines · David Teigland
Quoted 13 lines · Kevin Anderson

Hi all,

Recently we had cluster customer where the fencing agent successfully powered off a node, but the script failed to power the node back on due to firmware changes on the fencing device.

Question is whether we should consider this a successful fence event or
does the agent have to complete everything? The primary purpose of the
fencing agent is to stop the node from participating in the cluster. In this case, that was successful. But, because the power on attempt failed, the fence agent reported failure and the cluster hung waiting for a followup action.

Quoted 7 lines
Quoted 4 lines

It would seem to me that the fence agent should report success in this case, and maybe post a warning message about the failure to power on.

Thoughts?

Definately

Okay, next question, do our fence agents behave this way?

Kevin