Skip to contentSkip to conversation

S3C AUDIO: Rename s3c24xx_pcm prefix to s3c_dma

PATCH In review Jassi Brar 4 participants 10 messages Nov 5, 2009 – Nov 9, 2009

Subsystems (3)
lore
Share & tools
lore

Jassi Brar

author
#0 lore raw

PATCH 1/7 S3C AUDIO: Rename s3c24xx_pcm prefix to s3c_dma

The s3c24xx_pcm prefix for the soc_platform is inappropriate when some Samsung SoCs have PCM controllers which will eventually have drivers and hence namespace ambiguities.

To resolve naming ambiguities in future the following have been renamed in order
1) s3c24xx_pcm_dma_params -> s3c_audio_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dmamask
4) s3c24xx_pcm_XXX -> s3c_dma_XXX

---
 sound/soc/s3c24xx/s3c-i2s-v2.c   |    2 +-
 sound/soc/s3c24xx/s3c-i2s-v2.h   |    4 +-
 sound/soc/s3c24xx/s3c2412-i2s.c  |    4 +-
 sound/soc/s3c24xx/s3c2443-ac97.c |   10 ++--
 sound/soc/s3c24xx/s3c24xx-i2s.c  |   10 ++--
 sound/soc/s3c24xx/s3c24xx-pcm.c  |   76 +++++++++++++++++++-------------------
 sound/soc/s3c24xx/s3c24xx-pcm.h  |    6 +-
 sound/soc/s3c24xx/s3c64xx-i2s.c  |    4 +-
 8 files changed, 58 insertions(+), 58 deletions(-)
sound/soc/s3c24xx/s3c-i2s-v2.c +1 -1
index 28b0ab2..9788e65 100644
@@ -394,7 +394,7 @@ static int s3c2412_i2s_trigger(struct snd_pcm_substream *substream, int cmd,
 	int capture = (substream->stream == SNDRV_PCM_STREAM_CAPTURE);
 	unsigned long irqs;
 	int ret = 0;
-	int channel = ((struct s3c24xx_pcm_dma_params *)
+	int channel = ((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->channel;
 
 	pr_debug("Entered %s\n", __func__);
sound/soc/s3c24xx/s3c-i2s-v2.h +2 -2
index f66854a..02e16db 100644
@@ -49,8 +49,8 @@ struct s3c_i2sv2_info {
 
 	unsigned char	 master;
 
-	struct s3c24xx_pcm_dma_params	*dma_playback;
-	struct s3c24xx_pcm_dma_params	*dma_capture;
+	struct s3c_audio_dma_params	*dma_playback;
+	struct s3c_audio_dma_params	*dma_capture;
 
 	u32		 suspend_iismod;
 	u32		 suspend_iiscon;
sound/soc/s3c24xx/s3c2412-i2s.c +2 -2
index ac5e47b..6bc13d5 100644
@@ -50,14 +50,14 @@ static struct s3c2410_dma_client s3c2412_dma_client_in = {
 	.name		= "I2S PCM Stereo in"
 };
 
-static struct s3c24xx_pcm_dma_params s3c2412_i2s_pcm_stereo_out = {
+static struct s3c_audio_dma_params s3c2412_i2s_pcm_stereo_out = {
 	.client		= &s3c2412_dma_client_out,
 	.channel	= DMACH_I2S_OUT,
 	.dma_addr	= S3C2410_PA_IIS + S3C2412_IISTXD,
 	.dma_size	= 4,
 };
 
-static struct s3c24xx_pcm_dma_params s3c2412_i2s_pcm_stereo_in = {
+static struct s3c_audio_dma_params s3c2412_i2s_pcm_stereo_in = {
 	.client		= &s3c2412_dma_client_in,
 	.channel	= DMACH_I2S_IN,
 	.dma_addr	= S3C2410_PA_IIS + S3C2412_IISRXD,
sound/soc/s3c24xx/s3c2443-ac97.c +5 -5
index b25e9f9..d3bd29a 100644
@@ -188,21 +188,21 @@ static struct s3c2410_dma_client s3c2443_dma_client_micin = {
 	.name = "AC97 Mic Mono in"
 };
 
-static struct s3c24xx_pcm_dma_params s3c2443_ac97_pcm_stereo_out = {
+static struct s3c_audio_dma_params s3c2443_ac97_pcm_stereo_out = {
 	.client		= &s3c2443_dma_client_out,
 	.channel	= DMACH_PCM_OUT,
 	.dma_addr	= S3C2440_PA_AC97 + S3C_AC97_PCM_DATA,
 	.dma_size	= 4,
 };
 
-static struct s3c24xx_pcm_dma_params s3c2443_ac97_pcm_stereo_in = {
+static struct s3c_audio_dma_params s3c2443_ac97_pcm_stereo_in = {
 	.client		= &s3c2443_dma_client_in,
 	.channel	= DMACH_PCM_IN,
 	.dma_addr	= S3C2440_PA_AC97 + S3C_AC97_PCM_DATA,
 	.dma_size	= 4,
 };
 
-static struct s3c24xx_pcm_dma_params s3c2443_ac97_mic_mono_in = {
+static struct s3c_audio_dma_params s3c2443_ac97_mic_mono_in = {
 	.client		= &s3c2443_dma_client_micin,
 	.channel	= DMACH_MIC_IN,
 	.dma_addr	= S3C2440_PA_AC97 + S3C_AC97_MIC_DATA,
@@ -290,7 +290,7 @@ static int s3c2443_ac97_trigger(struct snd_pcm_substream *substream, int cmd,
 {
 	u32 ac_glbctrl;
 	struct snd_soc_pcm_runtime *rtd = substream->private_data;
-	int channel = ((struct s3c24xx_pcm_dma_params *)
+	int channel = ((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->channel;
 
 	ac_glbctrl = readl(s3c24xx_ac97.regs + S3C_AC97_GLBCTRL);
@@ -339,7 +339,7 @@ static int s3c2443_ac97_mic_trigger(struct snd_pcm_substream *substream,
 {
 	u32 ac_glbctrl;
 	struct snd_soc_pcm_runtime *rtd = substream->private_data;
-	int channel = ((struct s3c24xx_pcm_dma_params *)
+	int channel = ((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->channel;
 
 	ac_glbctrl = readl(s3c24xx_ac97.regs + S3C_AC97_GLBCTRL);
sound/soc/s3c24xx/s3c24xx-i2s.c +5 -5
index c76b8bb..998e752 100644
@@ -49,14 +49,14 @@ static struct s3c2410_dma_client s3c24xx_dma_client_in = {
 	.name = "I2S PCM Stereo in"
 };
 
-static struct s3c24xx_pcm_dma_params s3c24xx_i2s_pcm_stereo_out = {
+static struct s3c_audio_dma_params s3c24xx_i2s_pcm_stereo_out = {
 	.client		= &s3c24xx_dma_client_out,
 	.channel	= DMACH_I2S_OUT,
 	.dma_addr	= S3C2410_PA_IIS + S3C2410_IISFIFO,
 	.dma_size	= 2,
 };
 
-static struct s3c24xx_pcm_dma_params s3c24xx_i2s_pcm_stereo_in = {
+static struct s3c_audio_dma_params s3c24xx_i2s_pcm_stereo_in = {
 	.client		= &s3c24xx_dma_client_in,
 	.channel	= DMACH_I2S_IN,
 	.dma_addr	= S3C2410_PA_IIS + S3C2410_IISFIFO,
@@ -258,12 +258,12 @@ static int s3c24xx_i2s_hw_params(struct snd_pcm_substream *substream,
 	switch (params_format(params)) {
 	case SNDRV_PCM_FORMAT_S8:
 		iismod &= ~S3C2410_IISMOD_16BIT;
-		((struct s3c24xx_pcm_dma_params *)
+		((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->dma_size = 1;
 		break;
 	case SNDRV_PCM_FORMAT_S16_LE:
 		iismod |= S3C2410_IISMOD_16BIT;
-		((struct s3c24xx_pcm_dma_params *)
+		((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->dma_size = 2;
 		break;
 	default:
@@ -280,7 +280,7 @@ static int s3c24xx_i2s_trigger(struct snd_pcm_substream *substream, int cmd,
 {
 	int ret = 0;
 	struct snd_soc_pcm_runtime *rtd = substream->private_data;
-	int channel = ((struct s3c24xx_pcm_dma_params *)
+	int channel = ((struct s3c_audio_dma_params *)
 		  rtd->dai->cpu_dai->dma_data)->channel;
 
 	pr_debug("Entered %s\n", __func__);
sound/soc/s3c24xx/s3c24xx-pcm.c +38 -38

219 lines not on this page · raw message

sound/soc/s3c24xx/s3c24xx-pcm.h +3 -3
index 0088c79..d04ddf8 100644
@@ -9,13 +9,13 @@
  *  ALSA PCM interface for the Samsung S3C24xx CPU
  */
 
-#ifndef _S3C24XX_PCM_H
-#define _S3C24XX_PCM_H
+#ifndef _S3C_AUDIO_H
+#define _S3C_AUDIO_H
 
 #define ST_RUNNING		(1<<0)
 #define ST_OPENED		(1<<1)
 
-struct s3c24xx_pcm_dma_params {
+struct s3c_audio_dma_params {
 	struct s3c2410_dma_client *client;	/* stream identifier */
 	int channel;				/* Channel ID */
 	dma_addr_t dma_addr;
sound/soc/s3c24xx/s3c64xx-i2s.c +2 -2
index b67eed5..03f5a6b 100644
@@ -46,7 +46,7 @@ static struct s3c2410_dma_client s3c64xx_dma_client_in = {
 	.name		= "I2S PCM Stereo in"
 };
 
-static struct s3c24xx_pcm_dma_params s3c64xx_i2s_pcm_stereo_out[2] = {
+static struct s3c_audio_dma_params s3c64xx_i2s_pcm_stereo_out[2] = {
 	[0] = {
 		.channel	= DMACH_I2S0_OUT,
 		.client		= &s3c64xx_dma_client_out,
@@ -61,7 +61,7 @@ static struct s3c24xx_pcm_dma_params s3c64xx_i2s_pcm_stereo_out[2] = {
 	},
 };
 
-static struct s3c24xx_pcm_dma_params s3c64xx_i2s_pcm_stereo_in[2] = {
+static struct s3c_audio_dma_params s3c64xx_i2s_pcm_stereo_in[2] = {
 	[0] = {
 		.channel	= DMACH_I2S0_IN,
 		.client		= &s3c64xx_dma_client_in,
Signature · 1 line
1.6.2.5
#1 lore raw
Quoted 11 lines · Jassi Brar

The s3c24xx_pcm prefix for the soc_platform is inappropriate when some Samsung SoCs have PCM controllers which will eventually have drivers and hence namespace ambiguities.

To resolve naming ambiguities in future the following have been renamed in order
1) s3c24xx_pcm_dma_params -> s3c_audio_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dmamask
4) s3c24xx_pcm_XXX -> s3c_dma_XXX

I think that it should have a consistent prefix: s3c_audio_dma_ or other prefix.

BTW, should we keep up s3c prefix? If we will change the prefix now, it is a chance alterable from s3c prefix to other prefix because there is a variety of samsung SoCs unused s3c prefix.

#2 lore raw
Quoted 13 lines · Joonyoung Shim
Quoted 11 lines · Jassi Brar

The s3c24xx_pcm prefix for the soc_platform is inappropriate when some Samsung SoCs have PCM controllers which will eventually have drivers and hence namespace ambiguities.

To resolve naming ambiguities in future the following have been renamed in order
1) s3c24xx_pcm_dma_params -> s3c_audio_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dmamask
4) s3c24xx_pcm_XXX -> s3c_dma_XXX

Quoted 2 lines

I think that it should have a consistent prefix: s3c_audio_dma_ or other prefix.

Ideally, Yes.
but if we try so, we have the following
1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask

none of which seem very nice.

Quoted 3 lines

BTW, should we keep up s3c prefix? If we will change the prefix now, it is a chance alterable from s3c prefix to other prefix because there is a variety of samsung SoCs unused s3c prefix.

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.
About changing the s3c prefix is a valid discussion, though.

#3 lore raw
Quoted 15 lines · jassi brar
Quoted 12 lines · Joonyoung Shim
Quoted 11 lines · Jassi Brar

The s3c24xx_pcm prefix for the soc_platform is inappropriate when some Samsung SoCs have PCM controllers which will eventually have drivers and hence namespace ambiguities.

To resolve naming ambiguities in future the following have been renamed in order
1) s3c24xx_pcm_dma_params -> s3c_audio_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dmamask
4) s3c24xx_pcm_XXX -> s3c_dma_XXX

Quoted 2 lines

I think that it should have a consistent prefix: s3c_audio_dma_ or other prefix.

Quoted 8 lines

Ideally, Yes.
but if we try so, we have the following
1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask

none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

Quoted 6 lines
Quoted 3 lines

BTW, should we keep up s3c prefix? If we will change the prefix now, it is a chance alterable from s3c prefix to other prefix because there is a variety of samsung SoCs unused s3c prefix.

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

Quoted 2 lines

About changing the s3c prefix is a valid discussion, though.

#4 lore raw
Quoted 7 lines · Joonyoung Shim
Quoted 4 lines · jassi brar

but if we try so, we have the following
1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask

Quoted 5 lines
Quoted 1 line

none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

I tend to agree with this. The actual rename needs to happen to free up the PCM name for the driver for the PCM hardware.

Quoted 5 lines
Quoted 3 lines

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

I also agree with this - if we're renaming this driver anyway then changing the prefix for it while we're at it seems reasonable, it means one less change in the future.

#5 lore raw
Quoted 2 lines · Joonyoung Shim
Quoted 1 line · jassi brar
Quoted 9 lines · Mark Brown
Quoted 5 lines
Quoted 3 lines

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

I also agree with this - if we're renaming this driver anyway then changing the prefix for it while we're at it seems reasonable, it means one less change in the future.

renaming is a box of worms which i dont wanna be the first to open. I would wait for a complete discussion on the naming conventions to happen and have a decision made before I do renaming.
Though, I can resend the patch with samsung_ prefix too, if everyone is willing to
hold their peace forever.

Quoted 5 lines
Quoted 4 lines
Quoted 4 lines

but if we try so, we have the following
1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask

Quoted 8 lines
Quoted 5 lines
Quoted 1 line

none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

I tend to agree with this. The actual rename needs to happen to free up the PCM name for the driver for the PCM hardware.

So taking into account the aforementioned point as well, you suggest
1) s3c24xx_pcm_dma_params -> samsung_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> samsung_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> samsung_dmamask
4) s3c24xx_pcm_XXX -> samsung_dma_XXX

Please clarify your net suggestion.

#6 lore raw
Quoted 26 lines · jassi brar
Quoted 2 lines · Joonyoung Shim
Quoted 1 line · jassi brar
Quoted 7 lines · Mark Brown
Quoted 4 lines
Quoted 3 lines

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

I also agree with this - if we're renaming this driver anyway then changing the prefix for it while we're at it seems reasonable, it means one less change in the future.

renaming is a box of worms which i dont wanna be the first to open. I would wait for a complete discussion on the naming conventions to happen and have a decision made before I do renaming.
Though, I can resend the patch with samsung_ prefix too, if everyone is willing to
hold their peace forever.

Quoted 8 lines
Quoted 8 lines
Quoted 5 lines

but if we try so, we have the following
1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask
none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

Quoted 9 lines
Quoted 2 lines

I tend to agree with this. The actual rename needs to happen to free up the PCM name for the driver for the PCM hardware.

So taking into account the aforementioned point as well, you suggest
1) s3c24xx_pcm_dma_params -> samsung_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> samsung_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> samsung_dmamask
4) s3c24xx_pcm_XXX -> samsung_dma_XXX

Hmm, i was missing about the DMA on the prior mail. We should consider the DMA with this. The DMA chip(PL330) of s5p CPUs differs with s3c CPUs. We first should desided whether use the existing DMA interface of s3c. If we use it, this prefix is better samsung than s3c.

The other option is using the DMA subsystem about s5p DMA. This need also implementing ASoC platform driver of s5p for DMA, so it is better two each different prefix than samsung. I have posted the s5p DMA driver using the DMA subsystem.
http://lists.infradead.org/pipermail/linux-arm-kernel/2009-September/000810.html

#7 lore raw
Quoted 42 lines · Joonyoung Shim
Quoted 26 lines · jassi brar
Quoted 2 lines · Joonyoung Shim
Quoted 1 line · jassi brar
Quoted 7 lines · Mark Brown
Quoted 4 lines
Quoted 3 lines

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

I also agree with this - if we're renaming this driver anyway then changing the prefix for it while we're at it seems reasonable, it means one less change in the future.

renaming is a box of worms which i dont wanna be the first to open. I would wait for a complete discussion on the naming conventions to happen and have a decision made before I do renaming.
Though, I can resend the patch with samsung_ prefix too, if everyone is willing to
hold their peace forever.

Quoted 8 lines
Quoted 8 lines
Quoted 5 lines

but if we try so, we have the following
 1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
 2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer
 3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask
none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

Quoted 9 lines
Quoted 2 lines

I tend to agree with this.  The actual rename needs to happen to free up the PCM name for the driver for the PCM hardware.

So taking into account the aforementioned point as well, you suggest
1) s3c24xx_pcm_dma_params -> samsung_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> samsung_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> samsung_dmamask
4) s3c24xx_pcm_XXX -> samsung_dma_XXX

Hmm, i was missing about the DMA on the prior mail. We should consider the DMA with this. The DMA chip(PL330) of s5p CPUs differs with s3c CPUs. We first should desided whether use the existing DMA interface of s3c. If we use it, this prefix is better samsung than s3c.

Quoted 5 lines

The other option is using the DMA subsystem about s5p DMA. This need also implementing ASoC platform driver of s5p for DMA, so it is better two each different prefix than samsung. I have posted the s5p DMA driver using the DMA subsystem.
http://lists.infradead.org/pipermail/linux-arm-kernel/2009-September/000810.html

It doesn't make much sense to base new drivers over a DMA driver which hasn't been accepted(no ACK no NAK to your code). So, currently I assume PL330 DMA api same as that of PL080.
_______________________________________________
Alsa-devel mailing list
[email protected]
http://mailman.alsa-project.org/mailman/listinfo/alsa-devel

#8 lore raw
Quoted 41 lines · jassi brar
Quoted 40 lines · Joonyoung Shim
Quoted 26 lines · jassi brar
Quoted 2 lines · Joonyoung Shim
Quoted 1 line · jassi brar
Quoted 7 lines · Mark Brown
Quoted 4 lines
Quoted 3 lines

These patches is not about changing naming conventions. Only changes, necessary to have a clean and consistent namespace after integrating PCM driver, have been made.

Agree, but you already are changing the prefix from s3c24xx to s3c.

I also agree with this - if we're renaming this driver anyway then changing the prefix for it while we're at it seems reasonable, it means one less change in the future.

renaming is a box of worms which i dont wanna be the first to open. I would wait for a complete discussion on the naming conventions to happen and have a decision made before I do renaming.
Though, I can resend the patch with samsung_ prefix too, if everyone is willing to
hold their peace forever.

Quoted 8 lines
Quoted 8 lines
Quoted 5 lines

but if we try so, we have the following
혻1) s3c24xx_pcm_dma_params -> s3c_dma_dma_params
혻2) s3c24xx_pcm_preallocate_dma_buffer -> s3c_dma_preallocate_dma_buffer 혻3) s3c24xx_pcm_dmamask -> s3c_dma_dmamask
none of which seem very nice.

You can modify the names for the consistent prefix. If you use s3c_dma_ prefix, for example, s3c24xx_pcm_dma_params can be to s3c_dma_params.

Quoted 8 lines
Quoted 2 lines

I tend to agree with this. 혻The actual rename needs to happen to free up the PCM name for the driver for the PCM hardware.

So taking into account the aforementioned point as well, you suggest
1) s3c24xx_pcm_dma_params -> samsung_dma_params
2) s3c24xx_pcm_preallocate_dma_buffer -> samsung_preallocate_dma_buffer
3) s3c24xx_pcm_dmamask -> samsung_dmamask
4) s3c24xx_pcm_XXX -> samsung_dma_XXX

Hmm, i was missing about the DMA on the prior mail. We should consider the DMA with this. The DMA chip(PL330) of s5p CPUs differs with s3c CPUs. We first should desided whether use the existing DMA interface of s3c. If we use it, this prefix is better samsung than s3c.

Quoted 9 lines
Quoted 5 lines

The other option is using the DMA subsystem about s5p DMA. This need also implementing ASoC platform driver of s5p for DMA, so it is better two each different prefix than samsung. I have posted the s5p DMA driver using the DMA subsystem.
http://lists.infradead.org/pipermail/linux-arm-kernel/2009-September/000810.html

It doesn't make much sense to base new drivers over a DMA driver which hasn't been accepted(no ACK no NAK to your code). So, currently I assume PL330 DMA api same as that of PL080.

I'm not sure which is better, but i think above option all is possible. I just concerns if use the existing s3c DMA interface, are not there some implementation problems or the naming problems?

I don't know why Ben doesn't use the DMA subsystem at s3c64xx CPU(PL080). I just think because the PL080 chip of s3c64xx has some customized parts or for the DMA interface compatibility of s3c24xx.

Ben, what do you think about this issue?
_______________________________________________
Alsa-devel mailing list
[email protected]
http://mailman.alsa-project.org/mailman/listinfo/alsa-devel

#9 lore raw
Quoted 3 lines · Joonyoung Shim

I don't know why Ben doesn't use the DMA subsystem at s3c64xx CPU(PL080). I just think because the PL080 chip of s3c64xx has some customized parts or for the DMA interface compatibility of s3c24xx.

I suspect it's the latter; using the DMA API would mean updating all the existing DMA drivers.

For audio use we'd probably also want to extend the DMA API to support circular operation which I don't think it did last time I looked at it, but that was when it was very shiny and new. Ideally we'd be able to have an ASoC DMA engine API client which would work over multiple platforms which would be very nice.