ppc4xx: DDR/ECC: Use correct macros to clear error status
PATCH 2/2 ppc4xx: DDR/ECC: Use correct macros to clear error status
Use the correct macro instead of the hardcoded 0x4c to clear the ECC status in the 440/460 DDR(2) error status register after ECC initialization.
Also the non-440 parts (405EX(r) right now) and the IBM DDR PPC variants (440GX) use a different registers to clear this error status. Use the correct ones.
--- arch/powerpc/cpu/ppc4xx/ecc.c | 21 ++++++++++++++++++++- arch/powerpc/include/asm/ppc4xx-sdram.h | 2 ++ 2 files changed, 22 insertions(+), 1 deletions(-)
arch/powerpc/cpu/ppc4xx/ecc.c +20 -1
@@ -130,7 +130,26 @@ static void program_ecc_addr(unsigned long start_address,/* clear ECC error repoting registers */ mtsdram (SDRAM_ECCES ,0xffffffff ); -mtdcr (0x4c ,0xffffffff ); +#if defined(CONFIG_SDRAM_PPC4xx_IBM_DDR) +/* +* IBM DDR(1) core (440GX): +* Clear Mx bits in SDRAM0_BESR0/1 +*/ +mtsdram (SDRAM0_BESR0 ,0xffffffff ); +mtsdram (SDRAM0_BESR1 ,0xffffffff ); +#elif defined(CONFIG_440 ) +/* +* 440/460 DDR2 core: +* Clear EMID (Error PLB Master ID) in MQ0_ESL +*/ +mtdcr (SDRAM_ERRSTATLL ,0xfff00000 ); +#else +/* +* 405EX(r) DDR2 core: +* Clear M0ID (Error PLB Master ID) in SDRAM_BESR +*/ +mtsdram (SDRAM_BESR ,0xf0000000 ); +#endif mtsdram (SDRAM_MCOPT1 , (mcopt1 & ~SDRAM_MCOPT1_MCHK_MASK ) |SDRAM_MCOPT1_MCHK_CHK_REP );
arch/powerpc/include/asm/ppc4xx-sdram.h +2 -0
@@ -63,6 +63,8 @@#define SDRAM_CFG0 0x20/* memory controller options 0 */ #define SDRAM_CFG1 0x21/* memory controller options 1 */ +#define SDRAM0_BESR0 0x0000/* bus error status reg 0 */ +#define SDRAM0_BESR1 0x0008/* bus error status reg 1 */ #define SDRAM0_BEAR 0x0010/* bus error address reg */ #define SDRAM0_SLIO 0x0018/* ddr sdram slave interface options */ #define SDRAM0_CFG0 0x0020/* ddr sdram options 0 */
Signature · 1 line
1.7.1.1
PATCH 2/2 ppc4xx: DDR/ECC: Use correct macros to clear error status
Quoted 7 lines · On Wednesday 21 July 2010 11:08:27 Stefan Roese wrote:
Use the correct macro instead of the hardcoded
0x4cto clear the ECC status in the 440/460 DDR(2) error status register after ECC initialization.Also the non-440 parts (405EX(r) right now) and the IBM DDR PPC variants (440GX) use a different registers to clear this error status. Use the correct ones.
Applied to u-boot-ppc4xx/master. Thanks.
Cheers,
Stefan
--