hwmon: Add tempX_emergency attribute to sysfs ABI
Subsystems (2)
PATCH v2 1/1 hwmon: Add tempX_emergency attribute to sysfs ABI
Signed-off-by Guenter Roeck <[email protected]>
---
v2: Re-phrased attribute description
Documentation/hwmon/sysfs-interface | 7 +++++++ 1 files changed, 7 insertions(+), 0 deletions(-)
Documentation/hwmon/sysfs-interface +7 -0
@@ -310,6 +310,13 @@ temp[1-*]_crit_hyst from the critical value. RW +temp[1-*]_emergency + Temperature emergency max value, for chips supporting more than + two upper temperature limits. Must be equal or greater than + corresponding temp_crit values. + Unit: millidegree Celsius + RW + temp[1-*]_lcrit Temperature critical min value, typically lower than corresponding temp_min values. Unit: millidegree Celsius
Signature · 7 lines
1.7.0.87.g0901d _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
Jean Delvare
AppliedQuoted 15 lines · Guenter Roeck
Signed-off-by Guenter Roeck <[email protected]>---
v2: Re-phrased attribute descriptionDocumentation/hwmon/sysfs-interface | 7 +++++++ 1 files changed, 7 insertions(+), 0 deletions(-)Documentation/hwmon/sysfs-interface +0
-0@@ -310,6 +310,13 @@ temp[1-*]_crit_hyst from the critical value. RW
Documentation/hwmon/sysfs-interface temp[1-*]_crit_hyst · line 322
Quoted 10 lines
Documentation/hwmon/sysfs-interface +7
-0+temp[1-*]_emergency + Temperature emergency max value, for chips supporting more than + two upper temperature limits. Must be equal or greater than + corresponding temp_crit values. + Unit: millidegree Celsius + RW + temp[1-*]_lcrit Temperature critical min value, typically lower than corresponding temp_min values. Unit: millidegree Celsius
Applied, thanks.
Signature · 6 lines
Jean Delvare _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors