serial8250: Mark console as CON_ANYTIME
While trying to debug a cpu-hotplug issue I noticed printk() stopped working once the cpu got marked offline, since the 8250 serial console doesn't have any per-cpu resources the CON_ANYTIME bit is the safe and documented way to make it work again.
Signed-off-by Peter Zijlstra <[email protected]>
--- drivers/serial/8250.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-)
drivers/serial/8250.c +1 -1