Skip to contentSkip to conversation

regulator: Call into regulator driver only when voltage min/max really changes.

PATCH In review Saravana Kannan 3 participants 7 messages Dec 12, 2010 – Dec 13, 2010

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 regulator: Call into regulator driver only when voltage min/max really changes.

Even in cases where the consumer driver calls the regulator core with different voltage min/max values, the application of the various voltage constraints could result in the min/max voltage values passed to the regulator driver to be unchanged since the previous invocation.

Optimize these cases by not calling into the regulator driver and not sending incorrect/unnecessary voltage change notifications.

---
 drivers/regulator/core.c |   10 ++++++++--
 1 files changed, 8 insertions(+), 2 deletions(-)
drivers/regulator/core.c +8 -2
index ba521f0..c2e67bb 100644
@@ -1640,12 +1640,18 @@ int regulator_set_voltage(struct regulator *regulator, int min_uV, int max_uV)
 	ret = regulator_check_voltage(rdev, &min_uV, &max_uV);
 	if (ret < 0)
 		goto out;
-	regulator->min_uV = min_uV;
-	regulator->max_uV = max_uV;
+
+	if (regulator->min_uV == min_uV && regulator->max_uV == max_uV)
+		goto unlock;
 	ret = rdev->desc->ops->set_voltage(rdev, min_uV, max_uV);
+	if (!ret) {
+		regulator->min_uV = min_uV;
+		regulator->max_uV = max_uV;
+	}
 
 out:
 	_notifier_call_chain(rdev, REGULATOR_EVENT_VOLTAGE_CHANGE, NULL);
+unlock:
 	mutex_unlock(&rdev->mutex);
 	return ret;
 }
Signature · 4 lines
1.7.1.1
--
Sent by an employee of the Qualcomm Innovation Center, Inc.
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum.
Acked-by on v1 1/1
#1 lore raw
Quoted 4 lines · Saravana Kannan

Even in cases where the consumer driver calls the regulator core with different voltage min/max values, the application of the various voltage constraints could result in the min/max voltage values passed to the regulator driver to be unchanged since the previous invocation.

Out of interest do we have any examples of consumers that do this sufficiently often and/or in paths sufficiently performance critical for it to be an issue? Sounds like there might be room for optimisation in those consumers.

Quoted 2 lines

Optimize these cases by not calling into the regulator driver and not sending incorrect/unnecessary voltage change notifications.

The down side of doing this is that if the regulator state changes underneath us we've now got no way of recovering from that situation. This is something that's only partially supported by the API at the minute but it's nice to have a story about how drivers can work with this. I'll send a patch adding an explicit sync API.

#2 lore raw
Quoted 10 lines · Saravana Kannan
Quoted 4 lines

Even in cases where the consumer driver calls the regulator core with different voltage min/max values, the application of the various voltage constraints could result in the min/max voltage values passed to the regulator driver to be unchanged since the previous invocation.

Out of interest do we have any examples of consumers that do this sufficiently often and/or in paths sufficiently performance critical for it to be an issue? Sounds like there might be room for optimisation in those consumers.

Wouldn't it be better to optimize in one location (the core), instead of optimizing in several consumers?

I probably should have mentioned this too -- The other case this optimizes is the consumer calling with the same values. It can happen during CPU frequency scaling where multiple frequencies might have the same voltage level.

Quoted 10 lines
Quoted 2 lines

Optimize these cases by not calling into the regulator driver and not sending incorrect/unnecessary voltage change notifications.

The down side of doing this is that if the regulator state changes underneath us we've now got no way of recovering from that situation. This is something that's only partially supported by the API at the minute but it's nice to have a story about how drivers can work with this. I'll send a patch adding an explicit sync API.

Would this be a problem irrespective of this optimization?

Btw, after sending this patch, I just realized there might be another "bug" in the existing code (not my changes). What's the meaning of the "voltage change" event? It appears to be sent even if the regulator driver fails to set the voltage. It would be correct if the event just means "someone called set_voltage", but that seems like an unlikely definition. Let me know if I should send in a patch for that too.

Thanks,
Saravana

Signature · 2 lines
Sent by an employee of the Qualcomm Innovation Center, Inc.
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum.
#3 lore raw
Quoted 9 lines · On Sun, Dec 12, 2010 at 04:41:04AM -0800, [email protected] wrote:
Quoted 6 lines · Saravana Kannan

Out of interest do we have any examples of consumers that do this sufficiently often and/or in paths sufficiently performance critical for it to be an issue? Sounds like there might be room for optimisation in those consumers.

Wouldn't it be better to optimize in one location (the core), instead of optimizing in several consumers?

It's certainly good to optimise in the core, which is why I acked your patch, but it strikes me that if these consumers are regularly setting the regulator voltage to the same thing over and over again they may well also be doing whatever else goes along with setting the voltage over and over again and there's room for optimisation there also.

Quoted 7 lines
Quoted 5 lines

The down side of doing this is that if the regulator state changes underneath us we've now got no way of recovering from that situation. This is something that's only partially supported by the API at the minute but it's nice to have a story about how drivers can work with this. I'll send a patch adding an explicit sync API.

Would this be a problem irrespective of this optimization?

At the minute this can be handled at the consumer level since if the consumer knows that the voltage got changed underneath it (and if it cares about the voltage then it probably ought to know about this otherwise something is going to get upset) it can reconfigure the voltage by calling set_voltage() again.

Quoted 5 lines

Btw, after sending this patch, I just realized there might be another "bug" in the existing code (not my changes). What's the meaning of the "voltage change" event? It appears to be sent even if the regulator driver fails to set the voltage. It would be correct if the event just means "someone called set_voltage", but that seems like an unlikely definition.

It's an indication to other consumers that they might want to reread the voltage. Overnotification doesn't really hurt here, though it'd be nice to avoid it.

Quoted 1 line

Let me know if I should send in a patch for that too.

It'd probably coollide with the update I'm doing for syncing voltages.

#4 lore raw
In reply to Saravana Kannan
Quoted 4 lines · Saravana Kannan

Even in cases where the consumer driver calls the regulator core with different voltage min/max values, the application of the various voltage constraints could result in the min/max voltage values passed to the regulator driver to be unchanged since the previous invocation.

So, I tried to apply this against my local tree to avoid collisions with it but it doesn't apply so I suspect Liam will have trouble also, there are several updates in there that overlap with your change. Please regenerate against -next or Liam's tree:

git://git.kernel.org/pub/scm/linux/kernel/git/lrg/voltage-2.6

You should always submit changes against the development versions of code, generally -next will have these merged into it.

#5 lore raw
Quoted 10 lines

So, I tried to apply this against my local tree to avoid collisions with it but it doesn't apply so I suspect Liam will have trouble also, there are several updates in there that overlap with your change. Please regenerate against -next or Liam's tree:

git://git.kernel.org/pub/scm/linux/kernel/git/lrg/voltage-2.6

You should always submit changes against the development versions of code, generally -next will have these merged into it.

Will do. From a quick git log made it looked like for-linus was the latest. Looks like I was mistaken.

-Saravana

Signature · 2 lines
Sent by an employee of the Qualcomm Innovation Center, Inc.
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum.
#6 lore raw
In reply to Saravana Kannan
Quoted 9 lines · Saravana Kannan

Even in cases where the consumer driver calls the regulator core with different voltage min/max values, the application of the various voltage constraints could result in the min/max voltage values passed to the regulator driver to be unchanged since the previous invocation.

Optimize these cases by not calling into the regulator driver and not sending incorrect/unnecessary voltage change notifications.

This doesn't apply. Any chance you could regenerate against the regulator for-next branch ?

Thanks

Liam

Signature · 3 lines
Freelance Developer, SlimLogic Ltd
ASoC and Voltage Regulator Maintainer.