LVM2 add switch for mirror segtype selection
PATCH 1/1 LVM2 add switch for mirror segtype selection
This patch is to be folded into 'lvm-add-raid-support.patch'. It is only separated here to allow those who have already reviewed that patch to see what I've changed (in this case, a switch to allow the user to choose the default mirroring segment type).
lib/config/defaults.h +1 -0
@@ -49,6 +49,7 @@#define DEFAULT_USE_MLOCKALL 0#define DEFAULT_METADATA_READ_ONLY 0 +#define DEFAULT_MIRROR_SEGTYPE "mirror"#define DEFAULT_MIRRORLOG "disk"#define DEFAULT_MIRROR_LOG_FAULT_POLICY "allocate"#define DEFAULT_MIRROR_IMAGE_FAULT_POLICY "remove"
tools/lvcreate.c +3 -3
@@ -382,10 +382,10 @@ static int _lvcreate_params(struct lvcre/* * Check selected options are compatible and determine segtype */ + segtype_str ="striped" ;if (arg_count (cmd, mirrors_ARG)) - segtype_str ="mirror" ; -else - segtype_str ="striped" ; + segtype_str =find_config_tree_str (cmd,"activation/mirror_segtype_default" ,DEFAULT_MIRROR_SEGTYPE ); + lp->segtype =get_segtype_from_string (cmd,arg_str_value (cmd, type_ARG, segtype_str)); if (arg_count(cmd, snapshot_ARG) || seg_is_snapshot(lp) ||
doc/example.conf.in +21 -0
@@ -474,6 +474,27 @@ activation { # "auto" - Use default value chosen by kernel. readahead = "auto" + # 'mirror_segtype_default' defines which segtype will be used when the + # shorthand '-m' option is used for mirroring. The possible options are: + # + # "mirror" - The original RAID1 implementation provided by LVM2/DM. It is + # characterized by a flexible log solution (core, disk, mirrored) + # and by the necessity to block I/O while reconfiguring in the + # event of a failure. Snapshots of this type of RAID1 can be + # problematic. + # + # "raid1" - This implementation leverages MD's RAID1 personality through + # device-mapper. It is characterized by a lack of log options. + # (A log is always allocated for every device and they are placed + # on the same device as the image - no separate devices are + # required.) This mirror implementation does not require I/O + # to be blocked in the kernel in the event of a failure. + # + # If a user wishes to override this default setting, the '--type' option + # is available. Simply specify '--type <mirror|raid1>' along with the + # '-m' option when creating the mirror. + mirror_segtype_default = "mirror" + # 'mirror_image_fault_policy' and 'mirror_log_fault_policy' define # how a device failure affecting a mirror is handled. # A mirror is composed of mirror images (copies) and a log.