Skip to contentSkip to conversation

Handling multiple paths to enclosure devices?

DISCUSSION Roland Dreier 4 participants 7 messages Jul 28, 2011 – Jul 29, 2011 SCSI

lore
Share & tools
lore
#0 lore raw

Hi,

I'm seeing an issue with the current design of our enclosure handling. In a system with a bunch of drives in an enclosure, it's definitely helpful to have a way to go from sdXX to which slot in the enclosure that drive is in, and that's what the symlink /sys/block/sdXX/device/enclosure_device:NN provides.

However, in a system with multiple paths to the enclosure, eg an HBA with two external SAS ports, both connected to a SAS expander in a JBOD, ie in lame ASCII graphics, something like:

     +-----+                 /-- drv1
     |     |       +-----+  /---  .
     |     |==SAS==|     |-/----  .
     | HBA |       | exp |------  .
     |     |==SAS==|     |-\----  .
     |     |       +-----+  \---  .
     +-----+                 \-- drvN

we have two paths to each drive, so each gets two names, sdXX and sdYY. However, in drivers/misc/enclosure.c, the code only allows one device in each component and so what happens is that sdXX gets discovered, then gets an enclosure_device:NN link, then sdYY is discovered, so sdXX's enclosure_device:NN link is removed and one is added for sdYY. And so if I want to figure out which enclosure slot sdXX is in, I'm in for a hard time.

It would be a simple matter of writing code to allow all the block devices in a slot to link back to that slot -- we would have to be a bit more careful of keeping track of what links exist, but it should be doable.

The wrinkle is that there are also /sys/class/enclosure/ZZZ/NN/device symlinks that allow going the other way. And it's harder to see how to express multiple block devices in one enclosure slot.

Thoughts on how to improve our enclosure handling?

Thanks!
Roland

maintainer
#1 lore raw
Quoted 12 lines · Roland Dreier

Hi,

I'm seeing an issue with the current design of our enclosure handling. In a system with a bunch of drives in an enclosure, it's definitely helpful to have a way to go from sdXX to which slot in the enclosure that drive is in, and that's what the symlink /sys/block/sdXX/device/enclosure_device:NN provides.

However, in a system with multiple paths to the enclosure, eg an HBA with two external SAS ports, both connected to a SAS expander in a JBOD, ie in lame ASCII graphics, something like:

Quoted 7 lines
     +-----+                 /-- drv1
     |     |       +-----+  /---  .
     |     |==SAS==|     |-/----  .
     | HBA |       | exp |------  .
     |     |==SAS==|     |-\----  .
     |     |       +-----+  \---  .
     +-----+                 \-- drvN

So this configuration should form a single wide port and thus not actually be multiple paths. However, if you have two HBAs instead of one (or a non-SAS HBA), I grant it becomes multipath.

Quoted 13 lines

we have two paths to each drive, so each gets two names, sdXX and sdYY. However, in drivers/misc/enclosure.c, the code only allows one device in each component and so what happens is that sdXX gets discovered, then gets an enclosure_device:NN link, then sdYY is discovered, so sdXX's enclosure_device:NN link is removed and one is added for sdYY. And so if I want to figure out which enclosure slot sdXX is in, I'm in for a hard time.

It would be a simple matter of writing code to allow all the block devices in a slot to link back to that slot -- we would have to be a bit more careful of keeping track of what links exist, but it should be doable.

Quoted 5 lines

The wrinkle is that there are also /sys/class/enclosure/ZZZ/NN/device symlinks that allow going the other way. And it's harder to see how to express multiple block devices in one enclosure slot.

Thoughts on how to improve our enclosure handling?

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

How does that sound?

James

#2 lore raw
Quoted 3 lines

So this configuration should form a single wide port and thus not actually be multiple paths. However, if you have two HBAs instead of one (or a non-SAS HBA), I grant it becomes multipath.

Yeah ... actually my case is an HBA with two wide (4-lane) ports, where either the expander or the HBA is not able to fuse them into a single 8-lane port. But clearly this can happen at least with two HBAs pretty easily.

Quoted 7 lines

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

Ah, good insight: we do have two copies of the expander device, and so it would be natural to attach each disk to the expander device on the same path to that disk.

I'm a bit confused by what you mean about multi-path drivers though -- it would seem we would need the enclosure stuff to handle this somehow? It seems that if I have this situation, my HBA driver (eg mpt2sas) will discover the SCSI bus, hit an enclosure, trigger loading the ses driver (which pulls in the enclosure driver), and then continue discovering disks. And it seems this code needs to get the topology sorted by itself -- how could a multi-path driver inject itself into the symlink creation in enclosure.c?

- R.

#6 lore raw
In reply to James Bottomley
Quoted 21 lines · James Bottomley
Quoted 12 lines · Roland Dreier

Hi,

I'm seeing an issue with the current design of our enclosure handling. In a system with a bunch of drives in an enclosure, it's definitely helpful to have a way to go from sdXX to which slot in the enclosure that drive is in, and that's what the symlink /sys/block/sdXX/device/enclosure_device:NN provides.

However, in a system with multiple paths to the enclosure, eg an HBA with two external SAS ports, both connected to a SAS expander in a JBOD, ie in lame ASCII graphics, something like:

Quoted 7 lines
      +-----+                 /-- drv1
      |     |       +-----+  /---  .
      |     |==SAS==|     |-/----  .
      | HBA |       | exp |------  .
      |     |==SAS==|     |-\----  .
      |     |       +-----+  \---  .
      +-----+                 \-- drvN
Quoted 3 lines

So this configuration should form a single wide port and thus not actually be multiple paths. However, if you have two HBAs instead of one (or a non-SAS HBA), I grant it becomes multipath.

Here are some conflicting results for the single HBA case. I tested two LSI HBAs separately, each with 8 phys and wired 5 of those phys to a LSI SAS-2 expander.

Here are the results for a SAS-1.1 (3 Gbps) 3444E HBA seen from a SMP DISCOVER on the expander:

  phy   5:T:attached:[5001517e85c3efe5:00  t(SATA)]  3 Gbps
  phy   7:T:attached:[5000c500215725bd:00  t(SSP)]  6 Gbps
  phy  12:T:attached:[500605b00006f263:03  i(SSP+STP+SMP)]  3 Gbps
  phy  20:T:attached:[500605b00006f264:04  i(SSP+STP+SMP)]  3 Gbps
  phy  21:T:attached:[500605b00006f264:05  i(SSP+STP+SMP)]  3 Gbps
  phy  22:T:attached:[500605b00006f264:06  i(SSP+STP+SMP)]  3 Gbps
  phy  23:T:attached:[500605b00006f264:07  i(SSP+STP+SMP)]  3 Gbps
  phy  24:D:attached:[5001517e85c3effd:00  V i(SSP+SMP) t(SSP)]  6 Gbps

That is two ports:
- a narrow port [HBA phy 3 to expander phy 12]

    note the different SAS address of HBA phy 3: 500605b00006f263

- a wide port [HBA phys 4-7 to expander phys 20-23]
Should the HBA report as two hosts?? [It only reports as one host in my test.]

So if a SAS HBA can't handle a wide port with more than 4 phys, it can just change the SAS addresses on one or more phys at the HBA end.

Here are the results for a SAS-2 (6 Gbps) 9212 HBA seen from a SMP DISCOVER on the same expander:

  phy   5:T:attached:[5001517e85c3efe5:00  t(SATA)]  3 Gbps
  phy   7:T:attached:[5000c500215725bd:00  t(SSP)]  6 Gbps
  phy  12:T:attached:[500605b001d0d3e0:04  i(SSP+STP+SMP)]  6 Gbps
  phy  20:T:attached:[500605b001d0d3e0:03  i(SSP+STP+SMP)]  6 Gbps
  phy  21:T:attached:[500605b001d0d3e0:02  i(SSP+STP+SMP)]  6 Gbps
  phy  22:T:attached:[500605b001d0d3e0:01  i(SSP+STP+SMP)]  6 Gbps
  phy  23:T:attached:[500605b001d0d3e0:00  i(SSP+STP+SMP)]  6 Gbps
  phy  24:D:attached:[5001517e85c3effd:00  V i(SSP+SMP) t(SSP)]  6 Gbps

Now that is a single wide port (5 phys wide) since all 5 expander phys have the same SAS address (not shown) and all 5 HBA phys have the same address.

Quoted 13 lines
Quoted 13 lines

we have two paths to each drive, so each gets two names, sdXX and sdYY. However, in drivers/misc/enclosure.c, the code only allows one device in each component and so what happens is that sdXX gets discovered, then gets an enclosure_device:NN link, then sdYY is discovered, so sdXX's enclosure_device:NN link is removed and one is added for sdYY. And so if I want to figure out which enclosure slot sdXX is in, I'm in for a hard time.

It would be a simple matter of writing code to allow all the block devices in a slot to link back to that slot -- we would have to be a bit more careful of keeping track of what links exist, but it should be doable.

Quoted 5 lines
Quoted 5 lines

The wrinkle is that there are also /sys/class/enclosure/ZZZ/NN/device symlinks that allow going the other way. And it's harder to see how to express multiple block devices in one enclosure slot.

Thoughts on how to improve our enclosure handling?

IN SAS-2 the SMP DISCOVER response should contain slot information. Looking at sysfs for my test system:

# lsscsi
[1:0:0:0]    disk    ATA      ST3320620AS      3.AA  /dev/sda
[6:0:0:0]    disk    ATA      ST31000528AS     CC38  /dev/sdb
[6:0:1:0]    disk    SEAGATE  ST32000444SS     0006  /dev/sdc
[6:0:2:0]    enclosu Intel    RES2SV240        0600  -

then fetching the corresponding SAS port addresses:

# lsscsi -t
[1:0:0:0]    disk    sata:                           /dev/sda
[6:0:0:0]    disk    sas:0x5001517e85c3efe5          /dev/sdb
[6:0:1:0]    disk    sas:0x5000c500215725bd          /dev/sdc
[6:0:2:0]    enclosu sas:0x5001517e85c3effd          -

Referring to the SMP DISCOVER response above, it can be seen that /dev/sdc is connected to expander phy 7. So getting the long form output for a SMP DISCOVER on phy 7 :

# smp_discover -p 7 /dev/bsg/expander-6\:0
Discover response:
  ...
  attached SAS address: 0x5000c500215725bd
  attached phy identifier: 0
  ...
  device slot number: 255
  device slot group number: 255
  device slot group output connector:

Sadly the value of 255 means not available. YMMV

Quoted 9 lines

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

How does that sound?

Does this also solve the problem reported a few weeks back in which a SES logical unit reported duplicate element descriptor names?

Doug Gilbert

maintainer
#3 lore raw
In reply to Roland Dreier
Quoted 12 lines · Roland Dreier
Quoted 7 lines

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

Ah, good insight: we do have two copies of the expander device, and so it would be natural to attach each disk to the expander device on the same path to that disk.

Quoted 8 lines

I'm a bit confused by what you mean about multi-path drivers though -- it would seem we would need the enclosure stuff to handle this somehow? It seems that if I have this situation, my HBA driver (eg mpt2sas) will discover the SCSI bus, hit an enclosure, trigger loading the ses driver (which pulls in the enclosure driver), and then continue discovering disks. And it seems this code needs to get the topology sorted by itself -- how could a multi-path driver inject itself into the symlink creation in enclosure.c?

I merely meant that our current philosophy is to layer multi-path awareness in a separate driver: dm. There's certainly no expander awareness in dm-mp at the moment, but there could be. It should be quite simple: match the expanders to something like a dm-exp and then basically use the slot information in the expander to construct dm devices for each of the physicals (the rule for dm device creation would be dm-exp slot matching).

James

#4 lore raw
Quoted 22 lines · James Bottomley
Quoted 12 lines · Roland Dreier
Quoted 7 lines

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

Ah, good insight: we do have two copies of the expander device, and so it would be natural to attach each disk to the expander device on the same path to that disk.

Quoted 8 lines

I'm a bit confused by what you mean about multi-path drivers though -- it would seem we would need the enclosure stuff to handle this somehow? It seems that if I have this situation, my HBA driver (eg mpt2sas) will discover the SCSI bus, hit an enclosure, trigger loading the ses driver (which pulls in the enclosure driver), and then continue discovering disks. And it seems this code needs to get the topology sorted by itself -- how could a multi-path driver inject itself into the symlink creation in enclosure.c?

Quoted 8 lines

I merely meant that our current philosophy is to layer multi-path awareness in a separate driver: dm. There's certainly no expander awareness in dm-mp at the moment, but there could be. It should be quite simple: match the expanders to something like a dm-exp and then basically use the slot information in the expander to construct dm devices for each of the physicals (the rule for dm device creation would be dm-exp slot matching).

Doesn't help as device-mapper is only concerned with block devices, what with dm devices being essentially abstract block devices.

But yes, we should stick to our current philosophy of treating multipath devices as separate trees underneath the accessing HBA.
We should not (and, in fact, cannot) try to map the external topology in sysfs, rather should stick to a logical view as seen from each HBA. So the enclosure class needs to be updated int include the HBA number in there to avoid duplicate links.

The correct mapping and accessing these 'multipathed enclosures' will then be left as an exercise to the reader :-)

Cheers,

Hannes

Signature · 8 lines
Dr. Hannes Reinecke		      zSeries & Storage
[email protected]			      +49 911 74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: J. Hawn, J. Guild, F. Imendörffer, HRB 16746 (AG Nürnberg)
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html
maintainer
#5 lore raw
Quoted 31 lines · Hannes Reinecke
Quoted 22 lines · James Bottomley
Quoted 12 lines · Roland Dreier
Quoted 7 lines

My initial thought is that in a multi-path situation, as above, we get two enclosures appearing as well (one down each path). If we incorporated the idea of topological subtrees into the identity matching code, we'd end up filling each of the enclosures with the path connected devices. That seems to be an easy situation for multi-path drivers to sort out and one requiring no alteration of the existing enclosure code (except to do the topological subtree search).

Ah, good insight: we do have two copies of the expander device, and so it would be natural to attach each disk to the expander device on the same path to that disk.

Quoted 8 lines

I'm a bit confused by what you mean about multi-path drivers though -- it would seem we would need the enclosure stuff to handle this somehow? It seems that if I have this situation, my HBA driver (eg mpt2sas) will discover the SCSI bus, hit an enclosure, trigger loading the ses driver (which pulls in the enclosure driver), and then continue discovering disks. And it seems this code needs to get the topology sorted by itself -- how could a multi-path driver inject itself into the symlink creation in enclosure.c?

Quoted 8 lines

I merely meant that our current philosophy is to layer multi-path awareness in a separate driver: dm. There's certainly no expander awareness in dm-mp at the moment, but there could be. It should be quite simple: match the expanders to something like a dm-exp and then basically use the slot information in the expander to construct dm devices for each of the physicals (the rule for dm device creation would be dm-exp slot matching).

Quoted 2 lines

Doesn't help as device-mapper is only concerned with block devices, what with dm devices being essentially abstract block devices.

Well, all SCSI devices are effectively block devices as far as DM sees it because they have request queues. It's exploiting a sick trick, I know, but I don't think it will be too difficult to express them in the current code.

Quoted 9 lines

But yes, we should stick to our current philosophy of treating multipath devices as separate trees underneath the accessing HBA. We should not (and, in fact, cannot) try to map the external topology in sysfs, rather should stick to a logical view as seen from each HBA. So the enclosure class needs to be updated int include the HBA number in there to avoid duplicate links.

The correct mapping and accessing these 'multipathed enclosures' will then be left as an exercise to the reader :-)

Agreed. I'm agnostic as to whether we trick dm or invent something new.

James