Skip to contentSkip to conversation

Health Thermometer Profile patches

PATCH In review Santiago Carot-Nemesio 2 participants 19 messages Sep 29, 2011 – Oct 10, 2011 Bluetooth drivers

lore
Share & tools
lore
#0 lore raw

This is a new set of patches for health thermometer profile. They include all fixes suggested previously.

[PATCH 1/9] Get thermometer service range to load the driver. [PATCH 2/9] Register Health Thermometer Interface [PATCH 3/9] Unregister Health Thermometer Interface [PATCH 4/9] Add functions to manage attio callbacks [PATCH 5/9] Add handler function to manage GATT indications [PATCH 6/9] Get all characteristics in thermometer service [PATCH 7/9] Read temperature type characteristic [PATCH 8/9] Read measurement interval characteristic [PATCH 9/9] Set Intermediate property if intermediate temp.

#1 lore raw

PATCH 1/9 Get thermometer service range to load the driver.

---
 thermometer/manager.c     |   13 ++++++++++++-
 thermometer/thermometer.c |    5 ++++-
 thermometer/thermometer.h |    3 ++-
 3 files changed, 18 insertions(+), 3 deletions(-)
thermometer/manager.c +12 -1
index 08f0e0a..b39094f 100644
@@ -21,9 +21,11 @@
  */
 
 #include <gdbus.h>
+#include <bluetooth/uuid.h>
 
 #include "adapter.h"
 #include "device.h"
+#include "att.h"
 #include "thermometer.h"
 #include "manager.h"
 
@@ -33,7 +35,16 @@ static DBusConnection *connection = NULL;
 
 static int thermometer_driver_probe(struct btd_device *device, GSList *uuids)
 {
-	return thermometer_register(connection, device);
+	struct att_primary *tattr;
+	GSList *list;
+
+	list = device_services_from_record(device, uuids);
+	if (!list)
+		return -1;
+
+	tattr = list->data;
+
+	return thermometer_register(connection, device, tattr);
 }
 
 static void thermometer_driver_remove(struct btd_device *device)
thermometer/thermometer.c +4 -1
index 3cd821a..027ae02 100644
@@ -21,12 +21,15 @@
  */
 
 #include <gdbus.h>
+#include <bluetooth/uuid.h>
 
 #include "adapter.h"
 #include "device.h"
+#include "att.h"
 #include "thermometer.h"
 
-int thermometer_register(DBusConnection *connection, struct btd_device *device)
+int thermometer_register(DBusConnection *connection, struct btd_device *device,
+						struct att_primary *tattr)
 {
 	/* TODO: Register Health Thermometer Interface */
 	return 0;
thermometer/thermometer.h +2 -1
index 0937444..298c9ad 100644
@@ -20,5 +20,6 @@
  *
  */
 
-int thermometer_register(DBusConnection *connection, struct btd_device *device);
+int thermometer_register(DBusConnection *connection, struct btd_device *device,
+						struct att_primary *tattr);
 void thermometer_unregister(struct btd_device *device);
Signature · 1 line
1.7.6.1
#2 lore raw

PATCH 2/9 Register Health Thermometer Interface

---
 thermometer/thermometer.c |  108 ++++++++++++++++++++++++++++++++++++++++++++-
 1 files changed, 107 insertions(+), 1 deletions(-)
thermometer/thermometer.c +107 -1
index 027ae02..a89d8a9 100644
@@ -25,13 +25,119 @@
 
 #include "adapter.h"
 #include "device.h"
+#include "error.h"
+#include "log.h"
+#include "gattrib.h"
 #include "att.h"
 #include "thermometer.h"
 
+#define THERMOMETER_INTERFACE "org.bluez.Thermometer"
+
+struct thermometer {
+	DBusConnection          *conn;		/* The connection to the bus */
+	struct btd_device       *dev;		/* Device reference */
+	struct att_range	*svc_range;	/* Thermometer range */
+};
+
+static GSList *thermometers = NULL;
+
+static void destroy_thermometer(gpointer user_data)
+{
+	struct thermometer *t = user_data;
+
+	dbus_connection_unref(t->conn);
+	btd_device_unref(t->dev);
+	g_free(t->svc_range);
+        g_free(t);
+}
+
+static DBusMessage *get_properties(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static DBusMessage *set_property(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static DBusMessage *register_watcher(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static DBusMessage *unregister_watcher(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static DBusMessage *enable_intermediate(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static DBusMessage *disable_intermediate(DBusConnection *conn, DBusMessage *msg,
+								void *data)
+{
+	/* TODO: */
+	return g_dbus_create_error(msg, ERROR_INTERFACE ".ThermometerError",
+						"Function not implemented.");
+}
+
+static GDBusMethodTable thermometer_methods[] = {
+	{ "GetProperties",	"",	"a{sv}",	get_properties },
+	{ "SetProperty",	"sv",	"",		set_property,
+						G_DBUS_METHOD_FLAG_ASYNC },
+	{ "RegisterWatcher",	"o",	"",		register_watcher },
+	{ "UnregisterWatcher",	"o",	"",		unregister_watcher },
+	{ "EnableIntermediateMeasurement", "o", "", enable_intermediate },
+	{ "DisableIntermediateMeasurement","o",	"", disable_intermediate },
+	{ }
+};
+
+static GDBusSignalTable thermometer_signals[] = {
+	{ "PropertyChanged",	"sv"	},
+	{ }
+};
+
 int thermometer_register(DBusConnection *connection, struct btd_device *device,
 						struct att_primary *tattr)
 {
-	/* TODO: Register Health Thermometer Interface */
+	const gchar *path = device_get_path(device);
+	struct thermometer *t;
+
+	t = g_new0(struct thermometer, 1);
+	t->conn = dbus_connection_ref(connection);
+	t->dev = btd_device_ref(device);
+	t->svc_range = g_new0(struct att_range, 1);
+	t->svc_range->start = tattr->start;
+	t->svc_range->end = tattr->end;
+
+	if (!g_dbus_register_interface(t->conn, path, THERMOMETER_INTERFACE,
+				thermometer_methods, thermometer_signals,
+				NULL, t, destroy_thermometer)) {
+		error("D-Bus failed to register %s interface",
+							THERMOMETER_INTERFACE);
+		destroy_thermometer(t);
+		return -1;
+	}
+
+	thermometers = g_slist_prepend(thermometers, t);
 	return 0;
 }
 
Signature · 1 line
1.7.6.1
#3 lore raw

PATCH 3/9 Unregister Health Thermometer Interface

---
 thermometer/thermometer.c |   23 ++++++++++++++++++++++-
 1 files changed, 22 insertions(+), 1 deletions(-)
thermometer/thermometer.c +22 -1
index a89d8a9..cdfe455 100644
@@ -51,6 +51,17 @@ static void destroy_thermometer(gpointer user_data)
         g_free(t);
 }
 
+static gint cmp_device(gconstpointer a, gconstpointer b)
+{
+	const struct thermometer *t = a;
+	const struct btd_device *dev = b;
+
+	if (dev == t->dev)
+		return 0;
+
+	return -1;
+}
+
 static DBusMessage *get_properties(DBusConnection *conn, DBusMessage *msg,
 								void *data)
 {
@@ -143,5 +154,15 @@ int thermometer_register(DBusConnection *connection, struct btd_device *device,
 
 void thermometer_unregister(struct btd_device *device)
 {
-	/* TODO: Unregister Health Thermometer Interface */
+	struct thermometer *t;
+	GSList *l;
+
+	l = g_slist_find_custom(thermometers, device, cmp_device);
+	if (!l)
+		return;
+
+	t = l->data;
+	thermometers = g_slist_remove(thermometers, t);
+	g_dbus_unregister_interface(t->conn, device_get_path(t->dev),
+							THERMOMETER_INTERFACE);
 }
Signature · 1 line
1.7.6.1
#4 lore raw

PATCH 4/9 Add functions to manage attio callbacks

---
 thermometer/thermometer.c |   29 +++++++++++++++++++++++++++++
 1 files changed, 29 insertions(+), 0 deletions(-)
thermometer/thermometer.c +29 -0
index cdfe455..e06c6da 100644
@@ -28,6 +28,7 @@
 #include "error.h"
 #include "log.h"
 #include "gattrib.h"
+#include "attio.h"
 #include "att.h"
 #include "thermometer.h"
 
@@ -36,7 +37,9 @@
 struct thermometer {
 	DBusConnection          *conn;		/* The connection to the bus */
 	struct btd_device       *dev;		/* Device reference */
+	GAttrib			*attrib;	/* GATT connection */
 	struct att_range	*svc_range;	/* Thermometer range */
+	gint                    attioid;	/* Att watcher id */
 };
 
 static GSList *thermometers = NULL;
@@ -45,6 +48,12 @@ static void destroy_thermometer(gpointer user_data)
 {
 	struct thermometer *t = user_data;
 
+	if (t->attioid)
+		btd_device_remove_attio_callback(t->dev, t->attioid);
+
+	if (t->attrib)
+		g_attrib_unref(t->attrib);
+
 	dbus_connection_unref(t->conn);
 	btd_device_unref(t->dev);
 	g_free(t->svc_range);
@@ -126,6 +135,23 @@ static GDBusSignalTable thermometer_signals[] = {
 	{ }
 };
 
+static void attio_connected_cb(GAttrib *attrib, gpointer user_data)
+{
+	struct thermometer *t = user_data;
+
+	t->attrib = g_attrib_ref(attrib);
+}
+
+static void attio_disconnected_cb(gpointer user_data)
+{
+	struct thermometer *t = user_data;
+
+	DBG("GATT Disconnected");
+
+	g_attrib_unref(t->attrib);
+	t->attrib = NULL;
+}
+
 int thermometer_register(DBusConnection *connection, struct btd_device *device,
 						struct att_primary *tattr)
 {
@@ -149,6 +175,9 @@ int thermometer_register(DBusConnection *connection, struct btd_device *device,
 	}
 
 	thermometers = g_slist_prepend(thermometers, t);
+
+	t->attioid = btd_device_add_attio_callback(device, attio_connected_cb,
+						attio_disconnected_cb, t);
 	return 0;
 }
 
Signature · 1 line
1.7.6.1
#5 lore raw

PATCH 5/9 Add handler function to manage GATT indications

---
 thermometer/thermometer.c |   17 +++++++++++++++++
 1 files changed, 17 insertions(+), 0 deletions(-)
thermometer/thermometer.c +17 -0
index e06c6da..f8c17c6 100644
@@ -40,6 +40,7 @@ struct thermometer {
 	GAttrib			*attrib;	/* GATT connection */
 	struct att_range	*svc_range;	/* Thermometer range */
 	gint                    attioid;	/* Att watcher id */
+	gint			attindid;	/* Att incications id */
 };
 
 static GSList *thermometers = NULL;
@@ -51,6 +52,9 @@ static void destroy_thermometer(gpointer user_data)
 	if (t->attioid)
 		btd_device_remove_attio_callback(t->dev, t->attioid);
 
+	if (t->attindid)
+		g_attrib_unregister(t->attrib, t->attindid);
+
 	if (t->attrib)
 		g_attrib_unref(t->attrib);
 
@@ -135,11 +139,19 @@ static GDBusSignalTable thermometer_signals[] = {
 	{ }
 };
 
+static void ind_handler(const uint8_t *pdu, uint16_t len, gpointer user_data)
+{
+	/* TODO: Process indication */
+}
+
 static void attio_connected_cb(GAttrib *attrib, gpointer user_data)
 {
 	struct thermometer *t = user_data;
 
 	t->attrib = g_attrib_ref(attrib);
+
+	t->attindid = g_attrib_register(t->attrib, ATT_OP_HANDLE_IND,
+							ind_handler, t, NULL);
 }
 
 static void attio_disconnected_cb(gpointer user_data)
@@ -148,6 +160,11 @@ static void attio_disconnected_cb(gpointer user_data)
 
 	DBG("GATT Disconnected");
 
+	if (t->attindid) {
+		g_attrib_unregister(t->attrib, t->attindid);
+		t->attindid = 0;
+	}
+
 	g_attrib_unref(t->attrib);
 	t->attrib = NULL;
 }
Signature · 1 line
1.7.6.1
#6 lore raw

PATCH 6/9 Get all characteristics in thermometer service

---
 thermometer/thermometer.c |  110 +++++++++++++++++++++++++++++++++++++++++++++
 1 files changed, 110 insertions(+), 0 deletions(-)
thermometer/thermometer.c +110 -0
index f8c17c6..f0b977e 100644
@@ -30,10 +30,15 @@
 #include "gattrib.h"
 #include "attio.h"
 #include "att.h"
+#include "gatt.h"
 #include "thermometer.h"
 
 #define THERMOMETER_INTERFACE "org.bluez.Thermometer"
 
+#define TEMPERATURE_TYPE_UUID		"00002a1d-0000-1000-8000-00805f9b34fb"
+#define INTERMEDIATE_TEMPERATURE_UUID	"00002a1e-0000-1000-8000-00805f9b34fb"
+#define MEASUREMENT_INTERVAL_UUID	"00002a21-0000-1000-8000-00805f9b34fb"
+
 struct thermometer {
 	DBusConnection          *conn;		/* The connection to the bus */
 	struct btd_device       *dev;		/* Device reference */
@@ -41,10 +46,31 @@ struct thermometer {
 	struct att_range	*svc_range;	/* Thermometer range */
 	gint                    attioid;	/* Att watcher id */
 	gint			attindid;	/* Att incications id */
+	GSList			*chars;		/* Characteristics */
+};
+
+struct characteristic {
+	struct att_char		attr;	/* Characteristic */
+	GSList			*desc;	/* Descriptors */
+	struct thermometer	*t;	/* Thermometer where the char belongs */
+};
+
+struct descriptor {
+	struct characteristic	*ch;
+	uint16_t		handle;
+	bt_uuid_t		uuid;
 };
 
 static GSList *thermometers = NULL;
 
+static void destroy_char(gpointer user_data)
+{
+	struct characteristic *c = user_data;
+
+	g_slist_free_full(c->desc, g_free);
+	g_free(c);
+}
+
 static void destroy_thermometer(gpointer user_data)
 {
 	struct thermometer *t = user_data;
@@ -58,6 +84,9 @@ static void destroy_thermometer(gpointer user_data)
 	if (t->attrib)
 		g_attrib_unref(t->attrib);
 
+	if (t->chars)
+		g_slist_free_full(t->chars, destroy_char);
+
 	dbus_connection_unref(t->conn);
 	btd_device_unref(t->dev);
 	g_free(t->svc_range);
@@ -75,6 +104,85 @@ static gint cmp_device(gconstpointer a, gconstpointer b)
 	return -1;
 }
 
+static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len,
+							gpointer user_data)
+{
+	/* TODO */
+}
+
+static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
+							gpointer user_data)
+{
+	/* TODO */
+}
+
+static void read_interval_cb(guint8 status, const guint8 *pdu, guint16 len,
+							gpointer user_data)
+{
+	/* TODO */
+}
+
+static void process_thermometer_char(struct characteristic *ch)
+{
+	GAttribResultFunc func;
+
+	if (g_strcmp0(ch->attr.uuid, INTERMEDIATE_TEMPERATURE_UUID) == 0) {
+		/* TODO: Change intermediate property and emit signal */
+		return;
+	} else if (g_strcmp0(ch->attr.uuid, TEMPERATURE_TYPE_UUID) == 0)
+		func = read_temp_type_cb;
+	else if (g_strcmp0(ch->attr.uuid, MEASUREMENT_INTERVAL_UUID) == 0)
+		func = read_interval_cb;
+	else
+		return;
+
+	gatt_read_char(ch->t->attrib, ch->attr.value_handle, 0, func, ch);
+}
+
+static void configure_thermometer_cb(GSList *characteristics, guint8 status,
+							gpointer user_data)
+{
+	struct thermometer *t = user_data;
+	GSList *l;
+
+	if (status) {
+		error("Discover thermometer characteristics: %s",
+							att_ecode2str(status));
+		return;
+	}
+
+	for (l = characteristics; l; l = l->next) {
+		struct att_char *c = l->data;
+		struct characteristic *ch;
+		uint16_t start, end;
+
+		ch = g_new0(struct characteristic, 1);
+		ch->attr.handle = c->handle;
+		ch->attr.properties = c->properties;
+		ch->attr.value_handle = c->value_handle;
+		memcpy(ch->attr.uuid, c->uuid, MAX_LEN_UUID_STR + 1);
+		ch->t = t;
+
+		t->chars = g_slist_append(t->chars, ch);
+
+		process_thermometer_char(ch);
+
+		start = c->value_handle + 1;
+
+		if (l->next) {
+			struct att_char *c = l->next->data;
+			if (start == c->handle)
+				continue;
+			end = c->handle - 1;
+		} else if (c->value_handle != t->svc_range->end)
+			end = t->svc_range->end;
+		else
+			continue;
+
+		gatt_find_info(t->attrib, start, end, discover_desc_cb, ch);
+	}
+}
+
 static DBusMessage *get_properties(DBusConnection *conn, DBusMessage *msg,
 								void *data)
 {
@@ -152,6 +260,8 @@ static void attio_connected_cb(GAttrib *attrib, gpointer user_data)
 
 	t->attindid = g_attrib_register(t->attrib, ATT_OP_HANDLE_IND,
 							ind_handler, t, NULL);
+	gatt_discover_char(t->attrib, t->svc_range->start, t->svc_range->end,
+					NULL, configure_thermometer_cb, t);
 }
 
 static void attio_disconnected_cb(gpointer user_data)
Signature · 1 line
1.7.6.1
#7 lore raw

PATCH 7/9 Read temperature type characteristic

---
 thermometer/thermometer.c |   31 ++++++++++++++++++++++++++++++-
 1 files changed, 30 insertions(+), 1 deletions(-)
thermometer/thermometer.c +30 -1
index f0b977e..b10d09e 100644
@@ -47,6 +47,13 @@ struct thermometer {
 	gint                    attioid;	/* Att watcher id */
 	gint			attindid;	/* Att incications id */
 	GSList			*chars;		/* Characteristics */
+	gboolean		intermediate;
+	guint8			type;
+	guint16			interval;
+	guint16			max;
+	guint16			min;
+	gboolean		has_type;
+	gboolean		has_interval;
 };
 
 struct characteristic {
@@ -113,7 +120,29 @@ static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len,
 static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
 							gpointer user_data)
 {
-	/* TODO */
+	struct characteristic *ch = user_data;
+	struct thermometer *t = ch->t;
+	uint8_t value[ATT_MAX_MTU];
+	int vlen;
+
+	if (status != 0) {
+		DBG("Temperature Type value read failed: %s",
+							att_ecode2str(status));
+		return;
+	}
+
+	if (!dec_read_resp(pdu, len, value, &vlen)) {
+		DBG("Protocol error.");
+		return;
+	}
+
+	if (vlen != 1) {
+		DBG("Invalid length for Temperature type");
+		return;
+	}
+
+	t->has_interval = TRUE;
+	t->type = (uint8_t) value[0];
 }
 
 static void read_interval_cb(guint8 status, const guint8 *pdu, guint16 len,
Signature · 1 line
1.7.6.1
#8 lore raw

PATCH 8/9 Read measurement interval characteristic

---
 thermometer/thermometer.c |   70 ++++++++++++++++++++++++++++++++++++++++++++-
 1 files changed, 69 insertions(+), 1 deletions(-)
thermometer/thermometer.c +69 -1
index b10d09e..8cfc0e4 100644
@@ -23,6 +23,7 @@
 #include <gdbus.h>
 #include <bluetooth/uuid.h>
 
+#include "dbus-common.h"
 #include "adapter.h"
 #include "device.h"
 #include "error.h"
@@ -111,6 +112,49 @@ static gint cmp_device(gconstpointer a, gconstpointer b)
 	return -1;
 }
 
+static void change_property(struct thermometer *t, const gchar *name,
+							gpointer value) {
+	if (g_strcmp0(name, "Intermediate") == 0) {
+		gboolean *intermediate = value;
+		if (t->intermediate == *intermediate)
+			return;
+
+		t->intermediate = *intermediate;
+		emit_property_changed(t->conn, device_get_path(t->dev),
+					THERMOMETER_INTERFACE, name,
+					DBUS_TYPE_BOOLEAN, &t->intermediate);
+	} else if (g_strcmp0(name, "Interval") == 0) {
+		uint16_t *interval = value;
+		if (t->has_interval && t->interval == *interval)
+			return;
+
+		t->has_interval = TRUE;
+		t->interval = *interval;
+		emit_property_changed(t->conn, device_get_path(t->dev),
+					THERMOMETER_INTERFACE, name,
+					DBUS_TYPE_UINT16, &t->interval);
+	} else if (g_strcmp0(name, "Maximum") == 0) {
+		uint16_t *max = value;
+		if (t->max == *max)
+			return;
+
+		t->max = *max;
+		emit_property_changed(t->conn, device_get_path(t->dev),
+					THERMOMETER_INTERFACE, name,
+					DBUS_TYPE_UINT16, &t->max);
+	} else if (g_strcmp0(name, "Minimum") == 0) {
+		uint16_t *min = value;
+		if (t->min == *min)
+			return;
+
+		t->min = *min;
+		emit_property_changed(t->conn, device_get_path(t->dev),
+					THERMOMETER_INTERFACE, name,
+					DBUS_TYPE_UINT16, &t->min);
+	} else
+		DBG("%s is not a thermometer property", name);
+}
+
 static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len,
 							gpointer user_data)
 {
@@ -148,7 +192,31 @@ static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
 static void read_interval_cb(guint8 status, const guint8 *pdu, guint16 len,
 							gpointer user_data)
 {
-	/* TODO */
+	struct characteristic *ch = user_data;
+	uint8_t value[ATT_MAX_MTU];
+	uint16_t *p, interval;
+	int vlen;
+
+	if (status != 0) {
+		DBG("Measurement Interval value read failed: %s",
+							att_ecode2str(status));
+		return;
+	}
+
+	if (!dec_read_resp(pdu, len, value, &vlen)) {
+		DBG("Protocol error\n");
+		return;
+	}
+
+	if (vlen < 2) {
+		DBG("Invalid Interval received");
+		return;
+	}
+
+	p = (uint16_t *) value;
+	interval = btohs(*p);
+
+	change_property(ch->t, "Interval", &interval);
 }
 
 static void process_thermometer_char(struct characteristic *ch)
Signature · 1 line
1.7.6.1
#9 lore raw

PATCH 9/9 Set Intermediate property if intermediate temp. characteristic is supported

---
 thermometer/thermometer.c |    3 ++-
 1 files changed, 2 insertions(+), 1 deletions(-)
thermometer/thermometer.c +2 -1
index 8cfc0e4..e9e93cf 100644
@@ -224,7 +224,8 @@ static void process_thermometer_char(struct characteristic *ch)
 	GAttribResultFunc func;
 
 	if (g_strcmp0(ch->attr.uuid, INTERMEDIATE_TEMPERATURE_UUID) == 0) {
-		/* TODO: Change intermediate property and emit signal */
+		gboolean intermediate = TRUE;
+		change_property(ch->t, "Intermediate", &intermediate);
 		return;
 	} else if (g_strcmp0(ch->attr.uuid, TEMPERATURE_TYPE_UUID) == 0)
 		func = read_temp_type_cb;
Signature · 1 line
1.7.6.1
#18 lore raw

Re: [PATCH 1/9] Get thermometer service range to load the driver.

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/manager.c static DBusConnection *connection = NULL; · line 43

Quoted 9 lines · Santiago Carot-Nemesio

static int thermometer_driver_probe(struct btd_device *device, GSList *uuids) {

thermometer/manager.c +6 -1
-	return thermometer_register(connection, device);
+	struct att_primary *tattr;
+	GSList *list;
+
+	list = device_services_from_record(device, uuids);
+	if (!list)
+		return -1;

Could you try to avoid -1 error values. Please choose some appropriate POSIX error code instead (e.g. EINVAL in this case). Also (and I know we're note very consistent with this) when you're testing whether a pointer is NULL use "pointer == NULL" instead of "!pointer". This makes is directly clear that this is not a variable of some boolean type.

Johan

#17 lore raw

Re: [PATCH 2/9] Register Health Thermometer Interface

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/thermometer.c line 40

Quoted 5 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +5 -0
+struct thermometer {
+	DBusConnection          *conn;		/* The connection to the bus */
+	struct btd_device       *dev;		/* Device reference */
+	struct att_range	*svc_range;	/* Thermometer range */
+};

This struct has inconsistent indentation between the variable types and their names. The first two ones use spaces whereas the third one uses a tab.

thermometer/thermometer.c line 51

Quoted 8 lines
thermometer/thermometer.c +8 -0
+static void destroy_thermometer(gpointer user_data)
+{
+	struct thermometer *t = user_data;
+
+	dbus_connection_unref(t->conn);
+	btd_device_unref(t->dev);
+	g_free(t->svc_range);
+        g_free(t);

Incorrect indentation for the last line (just spaces).

thermometer/thermometer.c line 141

Quoted 4 lines
thermometer/thermometer.c +3 -0
+	}
+
+	thermometers = g_slist_prepend(thermometers, t);
 	return 0;

Minor nitpick: add an empty line before the return statement.

Johan

#16 lore raw

Re: [PATCH 3/9] Unregister Health Thermometer Interface

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/thermometer.c int thermometer_register(DBusConnection *connection, struct btd_device *device, · line 161

Quoted 2 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +2 -0
+	l = g_slist_find_custom(thermometers, device, cmp_device);
+	if (!l)

Same thing as I mentioned previously about comparing pointers.

Johan

#15 lore raw

Re: [PATCH 4/9] Add functions to manage attio callbacks

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/thermometer.c line 43

Quoted 8 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +2 -0
@@ -36,7 +37,9 @@
 struct thermometer {
 	DBusConnection          *conn;		/* The connection to the bus */
 	struct btd_device       *dev;		/* Device reference */
+	GAttrib			*attrib;	/* GATT connection */
 	struct att_range	*svc_range;	/* Thermometer range */
+	gint                    attioid;	/* Att watcher id */
 };

Looking at the attio.h API, the attioid should be guint and not gint, right? Also, this struct has the same inconsistency in indentation. Some lines use spaces whereas other use tabs. Please fix this (though potentially in a separate coding-style cleanup patch since the inconsistency exists there already before this patch).

thermometer/thermometer.c static void destroy_thermometer(gpointer user_data) · line 52

Quoted 2 lines
thermometer/thermometer.c +2 -0
+	if (t->attioid)
+		btd_device_remove_attio_callback(t->dev, t->attioid);

Please use if (t->attioid > 0)

Johan

#14 lore raw

Re: [PATCH 5/9] Add handler function to manage GATT indications

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/thermometer.c struct thermometer { · line 43

Quoted 5 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +1 -0
@@ -40,6 +40,7 @@ struct thermometer {
 	GAttrib			*attrib;	/* GATT connection */
 	struct att_range	*svc_range;	/* Thermometer range */
 	gint                    attioid;	/* Att watcher id */
+	gint			attindid;	/* Att incications id */

I suspect this should also be a guint?

thermometer/thermometer.c static void destroy_thermometer(gpointer user_data) · line 55

Quoted 1 line
thermometer/thermometer.c +1 -0
+	if (t->attindid)

attindid > 0

thermometer/thermometer.c static void attio_disconnected_cb(gpointer user_data) · line 166

Quoted 4 lines
thermometer/thermometer.c +4 -0
+	if (t->attindid) {
+		g_attrib_unregister(t->attrib, t->attindid);
+		t->attindid = 0;
+	}

attindid > 0

Johan

#13 lore raw

Re: [PATCH 6/9] Get all characteristics in thermometer service

In reply to Santiago Carot-Nemesio

Hi Santiago,

thermometer/thermometer.c static gint cmp_device(gconstpointer a, gconstpointer b) · line 148

Quoted 7 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +7 -0
+static void configure_thermometer_cb(GSList *characteristics, guint8 status,
+							gpointer user_data)
+{
+	struct thermometer *t = user_data;
+	GSList *l;
+
+	if (status) {

if (status != 0)

Johan

#12 lore raw

Re: [PATCH 7/9] Read temperature type characteristic

In reply to Santiago Carot-Nemesio

thermometer/thermometer.c static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len, · line 128

Quoted 11 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +6 -1
@@ -113,7 +120,29 @@ static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len,
 static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
 							gpointer user_data)
 {
-	/* TODO */
+	struct characteristic *ch = user_data;
+	struct thermometer *t = ch->t;
+	uint8_t value[ATT_MAX_MTU];
+	int vlen;
+
+	if (status != 0) {

This is correct. So why did you have "if (status)" in the previous patch?

thermometer/thermometer.c static void discover_desc_cb(guint8 status, const guint8 *pdu, guint16 len, · line 145

Quoted 1 line
thermometer/thermometer.c +1 -0
+	t->type = (uint8_t) value[0];

This looks like an unnecessary explicit type-cast. The array is already of type uint8_t.

Johan

#10 lore raw

Re: [PATCH 8/9] Read measurement interval characteristic

In reply to Santiago Carot-Nemesio

Hi Santiago,

Quoted 18 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +13 -1
@@ -148,7 +192,31 @@ static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
 static void read_interval_cb(guint8 status, const guint8 *pdu, guint16 len,
 							gpointer user_data)
 {
-	/* TODO */
+	struct characteristic *ch = user_data;
+	uint8_t value[ATT_MAX_MTU];
+	uint16_t *p, interval;
+	int vlen;
+
+	if (status != 0) {
+		DBG("Measurement Interval value read failed: %s",
+							att_ecode2str(status));
+		return;
+	}
+
+	if (!dec_read_resp(pdu, len, value, &vlen)) {
+		DBG("Protocol error\n");

thermometer/thermometer.c static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len, · line 217

Quoted 10 lines
thermometer/thermometer.c +10 -0
+		return;
+	}
+
+	if (vlen < 2) {
+		DBG("Invalid Interval received");
+		return;
+	}
+
+	p = (uint16_t *) value;
+	interval = btohs(*p);

This looks like a potential unaligned access issue. Probably safer to use bt_get_unaligned here.

Johan

#11 lore raw

Re: [PATCH 8/9] Read measurement interval characteristic

Hi Johan!

Thanks your comments.

2011/10/10 Johan Hedberg <[email protected]>:

Quoted 26 lines

Hi Santiago,

Quoted 23 lines · Santiago Carot-Nemesio
thermometer/thermometer.c +18 -1
@@ -148,7 +192,31 @@ static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len,
  static void read_interval_cb(guint8 status, const guint8 *pdu, guint16 len,
                                                       gpointer user_data)
  {
-     /* TODO */
+     struct characteristic *ch = user_data;
+     uint8_t value[ATT_MAX_MTU];
+     uint16_t *p, interval;
+     int vlen;
+
+     if (status != 0) {
+             DBG("Measurement Interval value read failed: %s",
+                                                     att_ecode2str(status));
+             return;
+     }
+
+     if (!dec_read_resp(pdu, len, value, &vlen)) {
+             DBG("Protocol error\n");
+             return;
+     }
+
+     if (vlen < 2) {
+             DBG("Invalid Interval received");
Quoted 8 lines

thermometer/thermometer.c static void read_temp_type_cb(guint8 status, const guint8 *pdu, guint16 len, · line 217

Quoted 5 lines
thermometer/thermometer.c +5 -0
+             return;
+     }
+
+     p = (uint16_t *) value;
+     interval = btohs(*p);

This looks like a potential unaligned access issue. Probably safer to use bt_get_unaligned here.

I'm going to review this and all previous issues you have mentioned
regarding to previous patches, when I get ready I'll send you a new set fixing them.

Once more, thank you all for your patient.

Regards.
Santiago