xl.pod.1: add a barebone description of tmem commands
PATCH 1/18 xl.pod.1: add a barebone description of tmem commands
From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 66 +++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 files changed, 66 insertions(+), 0 deletions(-)
docs/man/xl.pod.1 +66 -0
@@ -793,6 +793,72 @@ List pass-through pci devices for a domain. =back +=head2 TMEM + +=over 4 + +=item B<tmem-list> I[<-l>] I<domain-id> + +List tmem pools. If I<-l> is specified, also list tmem stats. + +=item B<tmem-freeze> I<domain-id> + +Freeze tmem pools. + +=item B<tmem-destroy> I<domain-id> + +Destroy tmem pools. + +=item B<tmem-thaw> I<domain-id> + +Thaw tmem pools. + +=item B<tmem-set> I<domain-id> [I<OPTIONS>] + +Change tmem settings. + +B<OPTIONS> + +=over 4 + +=item B<-w> I<WEIGHT> + +Weight (int) + +=item B<-c> I<CAP> + +Cap (int) + +=item B<-p> I<COMPRESS> + +Compress (int) + +=back + +=item B<tmem-shared-auth> I<domain-id> [I<OPTIONS>] + +De/authenticate shared tmem pool. + +B<OPTIONS> + +=over 4 + +=item B<-u> I<UUID> + +Specify uuid (abcdef01-2345-6789-1234-567890abcdef) + +=item B<-a> I<AUTH> + +0=auth,1=deauth + +=back + +=item B<tmem-freeable> + +Get information about how much freeable memory (MB) is in-use by tmem. + +=back + =head1 SEE ALSO B<xldomain.cfg>(5), B<xlcpupool.cfg>(5), B<xentop>(1)
Signature · 1 line
1.7.2.3
PATCH 2/18 xl.pod.1: add a description of console options
From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 19 ++++++++++++++++++- 1 files changed, 18 insertions(+), 1 deletions(-)
docs/man/xl.pod.1 +18 -1
@@ -105,7 +105,7 @@ soon as it is run. =back -=item B<console> I<domain-id> +=item B<console> [I<OPTIONS>] I<domain-id> Attach to domain I<domain-id>'s console. If you've set up your domains to have a traditional log in console this will look much like a normal
@@ -113,6 +113,23 @@ text log in screen. Use the key combination Ctrl+] to detach the domain console. +B<OPTIONS> + +=over 4 + +=item I<-t [pv|serial]> + +Connect to a PV console or connect to an emulated serial console. +PV consoles are the only consoles available for PV domains while HVM +domains can have both. If this option is not specified it defaults to +emulated serial for HVM guests. + +=item I<-n NUM> + +Connect to console number I<NUM>. Console numbers start from 0. + +=back + =item B<vncviewer> [I<OPTIONS>] I<domain-id> Attach to domain's VNC server, forking a vncviewer process.
Signature · 1 line
1.7.2.3
Re: [PATCH 02/18] xl.pod.1: add a description of console options
Quoted 24 lines · On Wed, 2011-11-09 at 16:50 +0000, [email protected] wrote:
From: Stefano Stabellini <[email protected]>
Signed-off-by Stefano Stabellini <[email protected]>--- docs/man/xl.pod.1 | 19 ++++++++++++++++++- 1 files changed, 18 insertions(+), 1 deletions(-)docs/man/xl.pod.1 +1
-1@@ -105,7 +105,7 @@ soon as it is run. =back -=item B<console> I<domain-id> +=item B<console> [I<OPTIONS>] I<domain-id> Attach to domain I<domain-id>'s console. If you've set up your domains to have a traditional log in console this will look much like a normal@@ -113,6 +113,23 @@ text log in screen. Use the key combination Ctrl+] to detach the domain console.
docs/man/xl.pod.1 text log in screen. · line 125
Quoted 10 lines
docs/man/xl.pod.1 +10
-0+B<OPTIONS> + +=over 4 + +=item I<-t [pv|serial]> + +Connect to a PV console or connect to an emulated serial console. +PV consoles are the only consoles available for PV domains while HVM +domains can have both. If this option is not specified it defaults to +emulated serial for HVM guests.
I know it can be inferred from the previous sentence (and is pretty obvious) but
If this option is not specified it defaults to emulated serial for HVM guests and PV console for PV guests.
is clearer.
Quoted 10 lines
docs/man/xl.pod.1 +7
-0+ +=item I<-n NUM> + +Connect to console number I<NUM>. Console numbers start from 0. + +=back + =item B<vncviewer> [I<OPTIONS>] I<domain-id> Attach to domain's VNC server, forking a vncviewer process.
Re: [PATCH 02/18] xl.pod.1: add a description of console options
Quoted 10 lines · Ian Campbell
docs/man/xl.pod.1 text log in screen. · line 125
Quoted 4 lines
docs/man/xl.pod.1 +4
-0+Connect to a PV console or connect to an emulated serial console. +PV consoles are the only consoles available for PV domains while HVM +domains can have both. If this option is not specified it defaults to +emulated serial for HVM guests.I know it can be inferred from the previous sentence (and is pretty obvious) but
If this option is not specified it defaults to emulated serial for HVM guests and PV console for PV guests.
is clearer.
You are right, I'll change it
PATCH 3/18 xl.pod.1: improve create documentation
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 22 ++++++++++++++++------ 1 files changed, 16 insertions(+), 6 deletions(-)
docs/man/xl.pod.1 +16 -6
@@ -52,13 +52,15 @@ previously, most commands take I<domain-id> as the first parameter. =over 4 -=item B<create> [I<OPTIONS>] I<configfile> +=item B<create> [I<configfile>] [I<OPTIONS>] -The create subcommand requires a config file: see L<xldomain.cfg> for -full details of that file format and possible options. +The create subcommand takes a config file as first argument: see +L<xldomain.cfg> for full details of that file format and possible +options. +If I<configfile> is missing B<XL> creates the domain starting from the +default value for every option. -I<configfile> can either be an absolute path to a file, or a relative -path to a file located in /etc/xen. +I<configfile> has to be an absolute path to a file. Create will return B<as soon> as the domain is started. This B<does not> mean the guest OS in the domain has actually booted, or is
@@ -88,7 +90,15 @@ Leave the domain paused after it is created. =item B<-c> Attach console to the domain as soon as it has started. This is -useful for determining issues with crashing domains. +useful for determining issues with crashing domains and just as a +general convenience since you often want to watch the +domain boot. + +=item B<key=value> + +It is possible to pass I<key=value> pairs on the command line to provide +options as if they were written in the configuration file; these override +whatever is in the I<configfile>. =back
Signature · 1 line
1.7.2.3
PATCH 4/18 xl.pod.1: add a description of the global options
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 16 ++++++++++++++++ 1 files changed, 16 insertions(+), 0 deletions(-)
docs/man/xl.pod.1 +16 -0
@@ -45,6 +45,22 @@ Most B<xl> commands require root privileges to run due to the communications channels used to talk to the hypervisor. Running as non root will return an error. +=head1 GLOBAL OPTIONS + +Few global options are always available: + +=over 4 + +=item B<-v> + +Verbose. + +=item B<-N> + +Dry run: do not actually execute the command. + +=back + =head1 DOMAIN SUBCOMMANDS The following subcommands manipulate domains directly. As stated
Signature · 1 line
1.7.2.3
Re: [PATCH 04/18] xl.pod.1: add a description of the global options
Quoted 12 lines · On Wed, 2011-11-09 at 16:50 +0000, [email protected] wrote:
From: Stefano Stabellini <[email protected]>
Signed-off-by Stefano Stabellini <[email protected]>--- docs/man/xl.pod.1 | 16 ++++++++++++++++ 1 files changed, 16 insertions(+), 0 deletions(-)docs/man/xl.pod.1 +0
-0
docs/man/xl.pod.1 Most B<xl> commands require root privileges to run due to the · line 50
Quoted 6 lines
docs/man/xl.pod.1 +3
-0@@ -45,6 +45,22 @@ Most B<xl> commands require root privileges to run due to the communications channels used to talk to the hypervisor. Running as non root will return an error. +=head1 GLOBAL OPTIONS + +Few global options are always available:
"A few..." or "Some...". "Few..." means that of the many global options only some of them are always available, or something like that.
Quoted 16 lines
docs/man/xl.pod.1 +13
-0+ +=over 4 + +=item B<-v> + +Verbose. + +=item B<-N> + +Dry run: do not actually execute the command. + +=back + =head1 DOMAIN SUBCOMMANDS The following subcommands manipulate domains directly. As stated
Re: [PATCH 04/18] xl.pod.1: add a description of the global options
Quoted 17 lines · Ian Campbell
Quoted 15 lines · On Wed, 2011-11-09 at 16:50 +0000, [email protected] wrote:
From: Stefano Stabellini <[email protected]>
Signed-off-by Stefano Stabellini <[email protected]>--- docs/man/xl.pod.1 | 16 ++++++++++++++++ 1 files changed, 16 insertions(+), 0 deletions(-)docs/man/xl.pod.1 +0
-0@@ -45,6 +45,22 @@ Most B<xl> commands require root privileges to run due to the communications channels used to talk to the hypervisor. Running as non root will return an error.
Quoted 6 lines
docs/man/xl.pod.1 Most B<xl> commands require root privileges to run due to the · line 50
Quoted 3 lines
docs/man/xl.pod.1 +3
-0+=head1 GLOBAL OPTIONS + +Few global options are always available:"A few..." or "Some...". "Few..." means that of the many global options only some of them are always available, or something like that.
OK, I'll change it
PATCH 5/18 xl.pod.1: order subcommands alphabetically
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 59 ++++++++++++++++++++++++++--------------------------- 1 files changed, 29 insertions(+), 30 deletions(-)
docs/man/xl.pod.1 +29 -30
@@ -68,6 +68,11 @@ previously, most commands take I<domain-id> as the first parameter. =over 4 +=item B<button-press> I<domain-id> I<button> + +Indicate an ACPI button press to the domain. I<button> is may be 'power' or +'sleep'. + =item B<create> [I<configfile>] [I<OPTIONS>] The create subcommand takes a config file as first argument: see
@@ -156,20 +161,6 @@ Connect to console number I<NUM>. Console numbers start from 0. =back -=item B<vncviewer> [I<OPTIONS>] I<domain-id> - -Attach to domain's VNC server, forking a vncviewer process. - -B<OPTIONS> - -=over 4 - -=item I<--autopass> - -Pass VNC password to vncviewer via stdin. - -=back - =item B<destroy> I<domain-id> Immediately terminate the domain I<domain-id>. This doesn't give the
@@ -196,6 +187,10 @@ I<filename> specified, without pausing the domain. The dump file will be written to a distribution specific directory for dump files. Such as: /var/lib/xen/dump or /var/xen/dump. +=item B<getenforce> + +Returns the current enforcing mode of the Flask Xen security module. + =item B<help> [I<--long>] Displays the short help message (i.e. common commands).
@@ -299,6 +294,10 @@ less utilized than a high CPU workload. Consider yourself warned. =back +=item B<loadpolicy> I<policyfile> + +Loads a new policy int the Flask Xen security module. + =item B<mem-max> I<domain-id> I<mem> Specify the maximum amount of memory the domain is able to use, appending 't'
@@ -387,6 +386,10 @@ Enable debug messages. =back +=item B<setenforce> I<1|0|Enforcing|Permissive> + +Sets the current enforcing mode of the Flask Xen security module + =item B<save> [I<OPTIONS>] I<domain-id> I<CheckpointFile> [I<ConfigFile>] Saves a running domain to a state file so that it can be restored
@@ -396,7 +399,6 @@ B<xl restore> restores from this checkpoint file. Passing a config file argument allows the user to manually select the VM config file used to create the domain. - =over 4 =item B<-c>
@@ -434,6 +436,11 @@ Send a I<Magic System Request> signal to the domain. For more information on available magic sys req operations, see sysrq.txt in your Linux Kernel sources. +=item B<trigger> I<domain-id> I<nmi|reset|init|power|sleep> [I<VCPU>] + +Send a trigger to a domain, where the trigger can be: nmi, reset, init, power +or sleep. Optionally a specific vcpu number can be passed as an argument. + =item B<unpause> I<domain-id> Moves a domain out of the paused state. This will allow a previously
@@ -473,27 +480,19 @@ different run state is appropriate. Pinning can be used to restrict this, by ensuring certain VCPUs can only run on certain physical CPUs. -=item B<button-press> I<domain-id> I<button> - -Indicate an ACPI button press to the domain. I<button> is may be 'power' or -'sleep'. - -=item B<trigger> I<domain-id> I<nmi|reset|init|power|sleep> [I<VCPU>] - -Send a trigger to a domain, where the trigger can be: nmi, reset, init, power -or sleep. Optionally a specific vcpu number can be passed as an argument. +=item B<vncviewer> [I<OPTIONS>] I<domain-id> -=item B<getenforce> +Attach to domain's VNC server, forking a vncviewer process. -Returns the current enforcing mode of the Flask Xen security module. +B<OPTIONS> -=item B<setenforce> I<1|0|Enforcing|Permissive> +=over 4 -Sets the current enforcing mode of the Flask Xen security module +=item I<--autopass> -=item B<loadpolicy> I<policyfile> +Pass VNC password to vncviewer via stdin. -Loads a new policy int the Flask Xen security module. +=back =back
Signature · 1 line
1.7.2.3
PATCH 6/18 xl.pod.1: remove the two FIXME
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 5 ++--- 1 files changed, 2 insertions(+), 3 deletions(-)
docs/man/xl.pod.1 +2 -3
@@ -264,7 +264,8 @@ scheduling by the Xen hypervisor. =item B<s - shutdown> -FIXME: Why would you ever see this state? +The guest OS has shut down (SCHEDOP_shutdown has been called) but the +domain is not dying yet. =item B<c - crashed>
@@ -277,8 +278,6 @@ restart on crash. See L<xldomain.cfg> for more info. The domain is in process of dying, but hasn't completely shutdown or crashed. -FIXME: Is this right? - =back B<NOTES>
Signature · 1 line
1.7.2.3
PATCH 7/18 xl.pod.1: add a reference to create in the -e option
In reply to [email protected]From: Stefano Stabellini <[email protected]>
Add a reference to the create subcommand in the description of the -e option to unpause and migrate.
--- docs/man/xl.pod.1 | 3 ++- 1 files changed, 2 insertions(+), 1 deletions(-)
docs/man/xl.pod.1 +2 -1
@@ -338,7 +338,7 @@ Use <sshcommand> instead of ssh. String will be passed to sh. If empty, run =item B<-e> On the new host, do not wait in the background (on <host>) for the death of the -domain. +domain. See the corresponding option of the I<create> subcommand. =item B<-C> I<config>
@@ -378,6 +378,7 @@ Do not unpause domain after restoring it. =item B<-e> Do not wait in the background for the death of the domain on the new host. +See the corresponding option of the I<create> subcommand. =item B<-d>
Signature · 1 line
1.7.2.3
PATCH 8/18 xl.pod.1: state when a command requires PV drivers installed
In reply to [email protected]From: Stefano Stabellini <[email protected]>
Remove an old incorrect comment about vcpu-set requiring cooperation from the guest.
--- docs/man/xl.pod.1 | 6 ++---- 1 files changed, 2 insertions(+), 4 deletions(-)
docs/man/xl.pod.1 +2 -4
@@ -358,6 +358,7 @@ Reboot a domain. This acts just as if the domain had the B<reboot> command run from the console. The command returns as soon as it has executed the reboot action, which may be significantly before the domain actually reboots. +It requires PV drivers installed in your guest OS. The behavior of what happens to a domain when it reboots is set by the B<on_reboot> parameter of the xldomain.cfg file when the domain was
@@ -415,6 +416,7 @@ to perform graceful shutdown, so there is no guarantee that it will succeed, and may take a variable length of time depending on what services must be shutdown in the domain. The command returns immediately after signally the domain unless that B<-w> flag is used. +For HVM domains it requires PV drivers to be installed in your guest OS. The behavior of what happens to a domain when it reboots is set by the B<on_shutdown> parameter of the xldomain.cfg file when the domain was
@@ -460,10 +462,6 @@ Attempting to set the VCPUs to a number larger than the initially configured VCPU count is an error. Trying to set VCPUs to < 1 will be quietly ignored. -Because this operation requires cooperation from the domain operating -system, there is no guarantee that it will succeed. This command will -not work with a full virt domain. - =item B<vcpu-list> [I<domain-id>] Lists VCPU information for a specific domain. If no domain is
Signature · 1 line
1.7.2.3
PATCH 9/18 xl.pod.1: better description for the sysreq subcommand
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 8 +++++--- 1 files changed, 5 insertions(+), 3 deletions(-)
docs/man/xl.pod.1 +5 -3
@@ -434,9 +434,11 @@ Wait for the domain to complete shutdown before returning. =item B<sysrq> I<domain-id> I<letter> -Send a I<Magic System Request> signal to the domain. For more -information on available magic sys req operations, see sysrq.txt in -your Linux Kernel sources. +Send a <Magic System Request> to the domain, each type of request is +represented by a different letter. +It can be used to send SysRq requests to Linux guests, see sysrq.txt in +your Linux Kernel sources for more information. +It requires PV drivers to be installed in your guest OS. =item B<trigger> I<domain-id> I<nmi|reset|init|power|sleep> [I<VCPU>]
Signature · 1 line
1.7.2.3
PATCH 10/18 xl.pod.1: state when a subcommand is only available to HVM guests
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 3 ++- 1 files changed, 2 insertions(+), 1 deletions(-)
docs/man/xl.pod.1 +2 -1
@@ -71,7 +71,7 @@ previously, most commands take I<domain-id> as the first parameter. =item B<button-press> I<domain-id> I<button> Indicate an ACPI button press to the domain. I<button> is may be 'power' or -'sleep'. +'sleep'. This command is only available for HVM domains. =item B<create> [I<configfile>] [I<OPTIONS>]
@@ -444,6 +444,7 @@ It requires PV drivers to be installed in your guest OS. Send a trigger to a domain, where the trigger can be: nmi, reset, init, power or sleep. Optionally a specific vcpu number can be passed as an argument. +This command is only available for HVM domains. =item B<unpause> I<domain-id>
Signature · 1 line
1.7.2.3
PATCH 11/18 xl.pod.1: introduce a TO BE DOCUMENTED section
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 16 ++++++++++++++++ 1 files changed, 16 insertions(+), 0 deletions(-)
docs/man/xl.pod.1 +16 -0
@@ -902,6 +902,22 @@ Get information about how much freeable memory (MB) is in-use by tmem. =back +=head1 TO BE DOCUMENTED + +We need better documentation for: + +=over 4 + +=item B<tmem> + +Trascendent Memory. + +=item B<Flask> + +Xen Flask security module. + +=back + =head1 SEE ALSO B<xldomain.cfg>(5), B<xlcpupool.cfg>(5), B<xentop>(1)
Signature · 1 line
1.7.2.3
PATCH 12/18 xl.pod.1: improve the debug-keys subcommand description
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 3 ++- 1 files changed, 2 insertions(+), 1 deletions(-)
docs/man/xl.pod.1 +2 -1
@@ -503,7 +503,8 @@ Pass VNC password to vncviewer via stdin. =item B<debug-keys> I<keys> -Send debug I<keys> to Xen. +Send debug I<keys> to Xen. It is the same as pressing the Xen +"conswitch" (Ctrl-A by default) three times and then pressing "keys". =item B<dmesg> [B<-c>]
Signature · 1 line
1.7.2.3
PATCH 13/18 xl.pod.1: improve the description of the info subcommand
In reply to [email protected]From: Stefano Stabellini <[email protected]>
also update the example
--- docs/man/xl.pod.1 | 55 +++++++++++++++++++++++++++------------------------- 1 files changed, 29 insertions(+), 26 deletions(-)
docs/man/xl.pod.1 +29 -26
@@ -527,39 +527,41 @@ Clears Xen's message buffer. Print information about the Xen host in I<name : value> format. When reporting a Xen bug, please provide this information as part of the -bug report. +bug report. See I<http://wiki.xen.org/xenwiki/ReportingBugs> on how to +report Xen bugs. -Sample output looks as follows (lines wrapped manually to make the man -page more readable): +Sample output looks as follows: - host : talon - release : 2.6.12.6-xen0 - version : #1 Mon Nov 14 14:26:26 EST 2005 - machine : i686 - nr_cpus : 2 + host : scarlett + release : 3.1.0-rc4+ + version : #1001 SMP Wed Oct 19 11:09:54 UTC 2011 + machine : x86_64 + nr_cpus : 4 nr_nodes : 1 - cores_per_socket : 1 + cores_per_socket : 4 threads_per_core : 1 - cpu_mhz : 696 - hw_caps : 0383fbff:00000000:00000000:00000040 - total_memory : 767 - free_memory : 37 - xen_major : 3 - xen_minor : 0 - xen_extra : -devel - xen_caps : xen-3.0-x86_32 + cpu_mhz : 2266 + hw_caps : bfebfbff:28100800:00000000:00003b40:009ce3bd:00000000:00000001:00000000 + virt_caps : hvm hvm_directio + total_memory : 6141 + free_memory : 4274 + free_cpus : 0 + xen_major : 4 + xen_minor : 2 + xen_extra : -unstable + xen_caps : xen-3.0-x86_64 xen-3.0-x86_32p hvm-3.0-x86_32 hvm-3.0-x86_32p hvm-3.0-x86_64 xen_scheduler : credit xen_pagesize : 4096 - platform_params : virt_start=0xfc000000 - xen_changeset : Mon Nov 14 18:13:38 2005 +0100 - 7793:090e44133d40 - cc_compiler : gcc version 3.4.3 (Mandrakelinux - 10.2 3.4.3-7mdk) - cc_compile_by : sdague - cc_compile_domain : (none) - cc_compile_date : Mon Nov 14 14:16:48 EST 2005 + platform_params : virt_start=0xffff800000000000 + xen_changeset : Wed Nov 02 17:09:09 2011 +0000 24066:54a5e994a241 + xen_commandline : com1=115200,8n1 guest_loglvl=all dom0_mem=750M console=com1 + cc_compiler : gcc version 4.4.5 (Debian 4.4.5-8) + cc_compile_by : sstabellini + cc_compile_domain : uk.xensource.com + cc_compile_date : Tue Nov 8 12:03:05 UTC 2011 xend_config_format : 4 + B<FIELDS> Not all fields will be explained here, but some of the less obvious
@@ -571,7 +573,8 @@ ones deserve explanation: A vector showing what hardware capabilities are supported by your processor. This is equivalent to, though more cryptic, the flags -field in /proc/cpuinfo on a normal Linux machine. +field in /proc/cpuinfo on a normal Linux machine: they both derive from +the feature bits returned by the cpuid command on x86 platforms. =item B<free_memory>
Signature · 1 line
1.7.2.3
PATCH 14/18 xl.pod.1: improve the description of pci-list-assignable-devices
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 3 +++ 1 files changed, 3 insertions(+), 0 deletions(-)
docs/man/xl.pod.1 +3 -0
@@ -615,6 +615,9 @@ Prints the current uptime of the domains running. =item B<pci-list-assignable-devices> List all the assignable PCI devices. +These are devices in the system which are configured to be +available for passthrough and are bound to a suitable PCI +backend driver in domain 0 rather than a real driver. =back
Signature · 1 line
1.7.2.3
PATCH 15/18 xl.pod.1: remove dry-run option from create and cpupool-create
In reply to [email protected]From: Stefano Stabellini <[email protected]>
there is already a global dry-run option, there is no point in adding another one for each subcommand
--- docs/man/xl.pod.1 | 9 --------- 1 files changed, 0 insertions(+), 9 deletions(-)
docs/man/xl.pod.1 +0 -9
@@ -99,11 +99,6 @@ No console output. Use the given configuration file. -=item B<-n>, B<--dryrun> - -Dry run - prints the resulting configuration in SXP but does not create -the domain. - =item B<-p> Leave the domain paused after it is created.
@@ -685,10 +680,6 @@ B<OPTIONS> Use the given configuration file. -=item B<-n>, B<--dryrun> - -Dry run - prints the resulting configuration. - =back =item B<cpupool-list> [I<-c|--cpus>] [I<cpu-pool>]
Signature · 1 line
1.7.2.3
PATCH 16/18 xl.pod.1: improve description of virtual device subcommands
In reply to [email protected]From: Stefano Stabellini <[email protected]>
Add a reference to docs/misc/xl-disk-configuration.txt and docs/misc/xl-network-configuration.markdown.
--- docs/man/xl.pod.1 | 18 +++++++++++++----- 1 files changed, 13 insertions(+), 5 deletions(-)
docs/man/xl.pod.1 +13 -5
@@ -717,8 +717,8 @@ Splits up the machine into one cpu-pool per numa node. =head1 VIRTUAL DEVICE COMMANDS Most virtual devices can be added and removed while guests are -running. The effect to the guest OS is much the same as any hotplug -event. +running, assuming that the necessary support exists in the guest. The +effect to the guest OS is much the same as any hotplug event. =head2 BLOCK DEVICES
@@ -740,7 +740,8 @@ The domain id of the guest domain that the device will be attached to. =item I<disc-spec-component> A disc specification in the same format used for the B<disk> variable in -the domain config file. See L<xldomain.cfg>. +the domain config file. See L<xldomain.cfg> and +I<docs/misc/xl-disk-configuration.txt>. =back
@@ -795,8 +796,8 @@ I<VirtualDevice> is the cdrom device in the guest to eject. Creates a new network device in the domain specified by I<domain-id>. I<network-device> describes the device to attach, using the same format as the -B<vif> string in the domain config file. See L<xldomain.cfg> for the -description. +B<vif> string in the domain config file. See L<xldomain.cfg> and +I<docs/misc/xl-network-configuration.markdown> for more informations. =item B<network-detach> I<domain-id> I<devid|mac>
@@ -918,8 +919,15 @@ Xen Flask security module. =head1 SEE ALSO +The following man pages: + B<xldomain.cfg>(5), B<xlcpupool.cfg>(5), B<xentop>(1) +And the following documents available in the Xen source tree: + +B<docs/misc/xl-network-configuration.markdown> +B<docs/misc/xl-disk-configuration.txt> + =head1 AUTHOR Stefano Stabellini <[email protected]>
Signature · 1 line
1.7.2.3
Re: [PATCH 16/18] xl.pod.1: improve description of virtual device subcommands
Quoted 4 lines · On Wed, 2011-11-09 at 16:50 +0000, [email protected] wrote:
docs/man/xl.pod.1 +0
-0@@ -918,8 +919,15 @@ Xen Flask security module. =head1 SEE ALSO
docs/man/xl.pod.1 Xen Flask security module. · line 931
Quoted 10 lines
docs/man/xl.pod.1 +7
-0+The following man pages: + B<xldomain.cfg>(5), B<xlcpupool.cfg>(5), B<xentop>(1) +And the following documents available in the Xen source tree: + +B<docs/misc/xl-network-configuration.markdown> +B<docs/misc/xl-disk-configuration.txt> + =head1 AUTHOR
I sent out a patch (yesterday, I think) which modified this section to reference xl-domain-config.markdown rather than xldomain.cfg so this will conflict, but otherwise this looks nice.
Ian.
Re: [PATCH 16/18] xl.pod.1: improve description of virtual device subcommands
Quoted 10 lines · Ian Campbell
Quoted 8 lines · On Wed, 2011-11-09 at 16:50 +0000, [email protected] wrote:
docs/man/xl.pod.1 +2
-0@@ -918,8 +919,15 @@ Xen Flask security module. =head1 SEE ALSO +The following man pages: + B<xldomain.cfg>(5), B<xlcpupool.cfg>(5), B<xentop>(1)
Quoted 10 lines
docs/man/xl.pod.1 Xen Flask security module. · line 931
Quoted 6 lines
docs/man/xl.pod.1 +5
-0+And the following documents available in the Xen source tree: + +B<docs/misc/xl-network-configuration.markdown> +B<docs/misc/xl-disk-configuration.txt> + =head1 AUTHORI sent out a patch (yesterday, I think) which modified this section to reference xl-domain-config.markdown rather than xldomain.cfg so this will conflict, but otherwise this looks nice.
I have just replied to that patch: I think that it is important that the domain config doc is available as a manpage too.
Given that is currently written in markdown we could use a tool to generate a manpage or convert the source into pod.
PATCH 17/18 xl.pod.1: remove AUTHORS section
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 7 ------- 1 files changed, 0 insertions(+), 7 deletions(-)
docs/man/xl.pod.1 +0 -7
@@ -928,13 +928,6 @@ And the following documents available in the Xen source tree: B<docs/misc/xl-network-configuration.markdown> B<docs/misc/xl-disk-configuration.txt> -=head1 AUTHOR - - Stefano Stabellini <[email protected]> - Vincent Hanquez <[email protected]> - Ian Jackson <[email protected]> - Ian Campbell <[email protected]> - =head1 BUGS Send bugs to [email protected].
Signature · 1 line
1.7.2.3
PATCH 18/18 xl.pod.1: add a refence to http://wiki.xen.org/xenwiki/ReportingBugs
In reply to [email protected]From: Stefano Stabellini <[email protected]>
--- docs/man/xl.pod.1 | 3 ++- 1 files changed, 2 insertions(+), 1 deletions(-)
docs/man/xl.pod.1 +2 -1
@@ -930,4 +930,5 @@ B<docs/misc/xl-disk-configuration.txt> =head1 BUGS -Send bugs to [email protected]. +Send bugs to [email protected], see +http://wiki.xen.org/xenwiki/ReportingBugs on how to send bug reports.
Signature · 1 line
1.7.2.3
Quoted 5 lines
From: [email protected] [mailto:[email protected]]
Sent: Wednesday, November 09, 2011 9:51 AM
To: [email protected]
Cc: [email protected]; [email protected]
Subject: [Xen-devel] [PATCH 01/18] xl.pod.1: add a barebone description of tmem commands
Oops, sorry, I saw the request for this awhile ago but it got buried.
Should I wait until this is committed into xen-unstable and provide a patch with more description (in pod)? Or do you want me to write some raw words that you can roll in to this patchset?
Dan
Quoted 6 lines · Dan Magenheimer
Quoted 5 lines
From: [email protected] [mailto:[email protected]]
Sent: Wednesday, November 09, 2011 9:51 AM
To: [email protected]
Cc: [email protected]; [email protected]
Subject: [Xen-devel] [PATCH 01/18] xl.pod.1: add a barebone description of tmem commands
Quoted 6 lines
Oops, sorry, I saw the request for this awhile ago but it got buried.
Should I wait until this is committed into xen-unstable and provide a patch with more description (in pod)? Or do you want me to write some raw words that you can roll in to this patchset?
An incremental patch on top of this one would be fine