Heart Rate Profile API
PATCH 1/1 Heart Rate Profile API
--- doc/heartrate-api.txt | 72 +++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 72 insertions(+) create mode 100644 doc/heartrate-api.txt
doc/heartrate-api.txt new file +72 -0
@@ -0,0 +1,72 @@ +BlueZ D-Bus Heart Rate API description +**************************************** + + Santiago Carot-Nemesio <[email protected]> + +Heart Rate Profile hierarchy +============================ + +Service org.bluez +Interface org.bluez.HeartRate +Object path [variable prefix]/{hci0,hci1,...}/dev_XX_XX_XX_XX_XX_XX + +Methods dict GetProperties() + + Returns all properties for the interface. See the + Properties section for the available properties. + + RegisterWatcher(object agent) + + Registers a watcher to monitor heart rate measurements. + + Possible Errors: org.bluez.Error.InvalidArguments + + UnregisterWatcher(object agent) + + Unregisters a watcher. + + Possible Errors: org.bluez.Error.InvalidArguments + org.bluez.Error.NotFound + + Reset() + + Restart the accumulation of energy expended from zero. + + Possible Errors: org.bluez.Error.NotSupported + +Properties boolean ResetSupported [readonly] + + True if energy expended is supported. + +Heart Rate Watcher hierarchy +============================ +Service unique name +Interface org.bluez.HeartRateWatcher +Object path freely definable + +Methods void MeasurementReceived(dict measure) + + This callback is called whenever a heart rate measurement + is received from the heart rate device. The unit for the + Value is expressed in beats per minute (bpm). The energy + field is optional and represents the accumulated energy + expended in kilo Joules since last time it was reset. + Furthermore, the device will be automatically reset when + it is needed. + The Contact field, if present, indicates that the device + supports contact sensor, besides it will be true if skin + contact is detected. The optional interval field is an + array containing RR-Interval values which represent the + time between two R-Wave detections, where the RR-Interval + Value 0 is older than the Value 1 and so on. + + Dict is defined as below: + { + "Value" : uint16, + "Energy" : uint16, + "Contact" : boolean, + "Location" : ("Other", "Chest", "Wrist","Finger", + "Hand", "Ear Lobe", "Foot"), + "Interval" : array{uint16} + } +
Signature · 1 line
1.7.9.2
Hi Santiago.
Quoted 4 lines · Santiago Carot-Nemesio
---
doc/heartrate-api.txt | 72 +++++++++++++++++++++++++++++++++++++++++++++++++1 file changed, 72 insertions(+)create mode 100644
doc/heartrate-api.txt
ack.
Regards,
Signature · 3 lines
Anderson Lizardo Instituto Nokia de Tecnologia - INdT Manaus - Brazil
Hi Santiago,
A couple of issues still:
doc/heartrate-api.txt line 4
Quoted 5 lines · Santiago Carot-Nemesio
doc/heartrate-api.txt new file +4
-0@@ -0,0 +1,72 @@ +BlueZ D-Bus Heart Rate API description +**************************************** + + Santiago Carot-Nemesio <[email protected]>
Is the above supposed to be a copyright statement? If so, fix it. (the documentation files need that anyway).
doc/heartrate-api.txt line 43
Quoted 3 lines
doc/heartrate-api.txt new file +3
-0+Heart Rate Watcher hierarchy +============================ +Service unique name
Add an empty line after the header.
Quoted 18 lines
doc/heartrate-api.txt new file +18
-0+Interface org.bluez.HeartRateWatcher +Object path freely definable + +Methods void MeasurementReceived(dict measure) + + This callback is called whenever a heart rate measurement + is received from the heart rate device. The unit for the + Value is expressed in beats per minute (bpm). The energy + field is optional and represents the accumulated energy + expended in kilo Joules since last time it was reset. + Furthermore, the device will be automatically reset when + it is needed. + The Contact field, if present, indicates that the device + supports contact sensor, besides it will be true if skin + contact is detected. The optional interval field is an + array containing RR-Interval values which represent the + time between two R-Wave detections, where the RR-Interval + Value 0 is older than the Value 1 and so on.
doc/heartrate-api.txt line 71
Quoted 10 lines
doc/heartrate-api.txt new file +10
-0+ + Dict is defined as below: + { + "Value" : uint16, + "Energy" : uint16, + "Contact" : boolean, + "Location" : ("Other", "Chest", "Wrist","Finger", + "Hand", "Ear Lobe", "Foot"), + "Interval" : array{uint16} + }
Please reformat the above to be less than 80 characters wide. Right now some lines are either 80 or 81.
Johan
Marcel Holtmann
maintainerHi Santiago,
Quoted 69 lines
doc/heartrate-api.txt | 72 +++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 72 insertions(+) create mode 100644 doc/heartrate-api.txtdoc/heartrate-api.txt new file +59
-0@@ -0,0 +1,72 @@ +BlueZ D-Bus Heart Rate API description +**************************************** + + Santiago Carot-Nemesio <[email protected]> + +Heart Rate Profile hierarchy +============================ + +Service org.bluez +Interface org.bluez.HeartRate +Object path [variable prefix]/{hci0,hci1,...}/dev_XX_XX_XX_XX_XX_XX + +Methods dict GetProperties() + + Returns all properties for the interface. See the + Properties section for the available properties. + + RegisterWatcher(object agent) + + Registers a watcher to monitor heart rate measurements. + + Possible Errors: org.bluez.Error.InvalidArguments + + UnregisterWatcher(object agent) + + Unregisters a watcher. + + Possible Errors: org.bluez.Error.InvalidArguments + org.bluez.Error.NotFound + + Reset() + + Restart the accumulation of energy expended from zero. + + Possible Errors: org.bluez.Error.NotSupported + +Properties boolean ResetSupported [readonly] + + True if energy expended is supported. + +Heart Rate Watcher hierarchy +============================ +Service unique name +Interface org.bluez.HeartRateWatcher +Object path freely definable + +Methods void MeasurementReceived(dict measure) + + This callback is called whenever a heart rate measurement + is received from the heart rate device. The unit for the + Value is expressed in beats per minute (bpm). The energy + field is optional and represents the accumulated energy + expended in kilo Joules since last time it was reset. + Furthermore, the device will be automatically reset when + it is needed. + The Contact field, if present, indicates that the device + supports contact sensor, besides it will be true if skin + contact is detected. The optional interval field is an + array containing RR-Interval values which represent the
doc/heartrate-api.txt line 69
Quoted 10 lines
doc/heartrate-api.txt new file +10
-0+ time between two R-Wave detections, where the RR-Interval + Value 0 is older than the Value 1 and so on. + + Dict is defined as below: + { + "Value" : uint16, + "Energy" : uint16, + "Contact" : boolean, + "Location" : ("Other", "Chest", "Wrist","Finger", + "Hand", "Ear Lobe", "Foot"),
values are lower-case and either one word or connected via -. Also I think it is earlobe and not ear lobe. Oxford dictionary please ;)
Regards
Marcel