Skip to contentSkip to conversation

Always update the dentry cache with fresh readdir() results

PATCH In review Andrew Bartlett 2 participants 10 messages Jul 5, 2012 – Jul 6, 2012 3 messages not in the archive

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

PATCH 1/1 Always update the dentry cache with fresh readdir() results

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org
Quoted 1 line

From 4478a902d3606205313eb37a225da22712841bff Mon Sep 17 00:00:00 2001

From: Andrew Bartlett <[email protected]>
Date: Thu, 5 Jul 2012 15:48:08 +1000
Subject: [PATCH] fs/cifs: Always recreate the cifs dentry cache when we have
fresh information

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, cache-able stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 against Samba 4.0 beta3.

Andrew Bartlett

---
 fs/cifs/readdir.c |   11 ++++++-----
 1 files changed, 6 insertions(+), 5 deletions(-)
fs/cifs/readdir.c +6 -5
index 0a8224d..f964b40 100644
@@ -66,9 +66,13 @@ static inline void dump_cifs_file_struct(struct file *file, char *label)
 #endif /* DEBUG2 */
 
 /*
- * Find the dentry that matches "name". If there isn't one, create one. If it's
- * a negative dentry or the uniqueid changed, then drop it and recreate it.
+ * Find the dentry that matches "name". If there isn't one, create
+ * one.  Otherwise recreate it fresh so we start the timeout for
+ * revalidation again.  Local locks are much faster than the network
+ * ops to revalidate it, particularly as revalidation will be
+ * per-inode, but here we have a whole directory at once!
  */
+
 static struct dentry *
 cifs_readdir_lookup(struct dentry *parent, struct qstr *name,
 		    struct cifs_fattr *fattr)
@@ -86,9 +90,6 @@ cifs_readdir_lookup(struct dentry *parent, struct qstr *name,
 
 	dentry = d_lookup(parent, name);
 	if (dentry) {
-		/* FIXME: check for inode number changes? */
-		if (dentry->d_inode != NULL)
-			return dentry;
 		d_drop(dentry);
 		dput(dentry);
 	}
Signature · 1 line
1.7.7.6
#1 lore raw

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org
#2 lore raw
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

-------------------------[snip]--------------------------

cifs: always update the inode cache with the results from a FIND_*

When we get back a FIND_FIRST/NEXT result, we have some info about the dentry that we use to instantiate a new inode. We were ignoring and discarding that info when we had an existing dentry in the cache.

Fix this by updating the inode in place when we find an existing dentry and the uniqueid is the same.

---
 fs/cifs/readdir.c |    7 +++++--
 1 files changed, 5 insertions(+), 2 deletions(-)
fs/cifs/readdir.c +5 -2
index 0a8224d..a4217f0 100644
@@ -86,9 +86,12 @@ cifs_readdir_lookup(struct dentry *parent, struct qstr *name,
 
 	dentry = d_lookup(parent, name);
 	if (dentry) {
-		/* FIXME: check for inode number changes? */
-		if (dentry->d_inode != NULL)
+		inode = dentry->d_inode;
+		/* update inode in place if i_ino didn't change */
+		if (inode && CIFS_I(inode)->uniqueid == fattr->cf_uniqueid) {
+			cifs_fattr_to_inode(inode, fattr);
 			return dentry;
+		}
 		d_drop(dentry);
 		dput(dentry);
 	}
Signature · 1 line
1.7.7.6

A message that is not in the archive (sent off-list or not yet received): 20120705072401.7eb1a7ee-4QP7MXygkU+dMjc06nkz3ljfA9RmPOcC@public.gmane.org

#4 lore raw
Quoted 32 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Quoted 6 lines

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Is it really safe to update so much without getting a lock over all the updates?

/* populate an inode with info from a cifs_fattr struct */ void
cifs_fattr_to_inode(struct inode *inode, struct cifs_fattr *fattr)

{
	struct cifsInodeInfo *cifs_i = CIFS_I(inode);
	struct cifs_sb_info *cifs_sb = CIFS_SB(inode->i_sb);
	unsigned long oldtime = cifs_i->time;

	cifs_revalidate_cache(inode, fattr);

	inode->i_atime = fattr->cf_atime;
	inode->i_mtime = fattr->cf_mtime;
	inode->i_ctime = fattr->cf_ctime;
	inode->i_rdev = fattr->cf_rdev;
	set_nlink(inode, fattr->cf_nlink);
	inode->i_uid = fattr->cf_uid;
	inode->i_gid = fattr->cf_gid;

	/* if dynperm is set, don't clobber existing mode */
	if (inode->i_state & I_NEW ||
	    !(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DYNPERM))
		inode->i_mode = fattr->cf_mode;

	cifs_i->cifsAttrs = fattr->cf_cifsattrs;

	if (fattr->cf_flags & CIFS_FATTR_NEED_REVAL)
		cifs_i->time = 0;
	else
		cifs_i->time = jiffies;

	cFYI(1, "inode 0x%p old_time=%ld new_time=%ld", inode,
		 oldtime, cifs_i->time);

	cifs_i->delete_pending = fattr->cf_flags & CIFS_FATTR_DELETE_PENDING;

	cifs_i->server_eof = fattr->cf_eof;
	/*
	 * Can't safely change the file size here if the client is writing to
	 * it due to potential races.
	 */
	spin_lock(&inode->i_lock);
	if (is_size_safe_to_change(cifs_i, fattr->cf_eof)) {
		i_size_write(inode, fattr->cf_eof);

		/*
		 * i_blocks is not related to (i_size / i_blksize),
		 * but instead 512 byte (2**9) size is required for
		 * calculating num blocks.
		 */
		inode->i_blocks = (512 - 1 + fattr->cf_bytes) >> 9;
	}
	spin_unlock(&inode->i_lock);

	if (fattr->cf_flags & CIFS_FATTR_DFS_REFERRAL)
		inode->i_flags |= S_AUTOMOUNT;
	cifs_set_ops(inode);
}

That is, I think the spin_lock() needs to be moved to the top of cifs_fattr_to_inode(). How is this safe for the current callers?

The equivalent code in NFS does this:

int nfs_refresh_inode(struct inode *inode, struct nfs_fattr *fattr)

{
	int status;

	if ((fattr->valid & NFS_ATTR_FATTR) == 0)
		return 0;
	spin_lock(&inode->i_lock);
	status = nfs_refresh_inode_locked(inode, fattr);
	spin_unlock(&inode->i_lock);

	return status;
}

In our case it will be more difficult, as cifs_fattr_to_inode() takes the inode->i_lock (but only for some updates).

I agree that it is important to call cifs_fattr_to_inode, because it is critical to call cifs_revalidate_cache(), to flush the fscache and to flush any cached pages.

Andrew Bartlett

Quoted 39 lines

-------------------------[snip]--------------------------

cifs: always update the inode cache with the results from a FIND_*

When we get back a FIND_FIRST/NEXT result, we have some info about the dentry that we use to instantiate a new inode. We were ignoring and discarding that info when we had an existing dentry in the cache.

Fix this by updating the inode in place when we find an existing dentry and the uniqueid is the same.

---
 fs/cifs/readdir.c |    7 +++++--
 1 files changed, 5 insertions(+), 2 deletions(-)
fs/cifs/readdir.c +5 -2
index 0a8224d..a4217f0 100644
@@ -86,9 +86,12 @@ cifs_readdir_lookup(struct dentry *parent, struct qstr *name,
 
 	dentry = d_lookup(parent, name);
 	if (dentry) {
-		/* FIXME: check for inode number changes? */
-		if (dentry->d_inode != NULL)
+		inode = dentry->d_inode;
+		/* update inode in place if i_ino didn't change */
+		if (inode && CIFS_I(inode)->uniqueid == fattr->cf_uniqueid) {
+			cifs_fattr_to_inode(inode, fattr);
 			return dentry;
+		}
 		d_drop(dentry);
 		dput(dentry);
 	}
Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org
#5 lore raw
Quoted 37 lines · On Fri, 06 Jul 2012 09:31:07 +1000 Andrew Bartlett…
Quoted 36 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Quoted 6 lines
Quoted 2 lines

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Is it really safe to update so much without getting a lock over all the updates?

What's your worry, specifically?

The vfs only requires that you hold the lock over i_size updates. I suppose it's possible that you could have racing updates to an inode, but in practice, the last one will generally "win".

Signature · 1 line
Jeff Layton <[email protected]>

A message that is not in the archive (sent off-list or not yet received): 20120705214608.2a3a681b-4QP7MXygkU+dMjc06nkz3ljfA9RmPOcC@public.gmane.org

#7 lore raw
Quoted 47 lines · Jeff Layton
Quoted 37 lines · On Fri, 06 Jul 2012 09:31:07 +1000 Andrew Bartlett…
Quoted 36 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Quoted 6 lines
Quoted 2 lines

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Is it really safe to update so much without getting a lock over all the updates?

Quoted 5 lines

What's your worry, specifically?

The vfs only requires that you hold the lock over i_size updates. I suppose it's possible that you could have racing updates to an inode, but in practice, the last one will generally "win".

Writes are a worry, and I'm not sure I like the idea of parallel updates being able to leave it in a undefined state, but I was more worried about a read, that is someone reading just between:

	inode->i_uid = fattr->cf_uid;
	inode->i_gid = fattr->cf_gid;

and

	/* if dynperm is set, don't clobber existing mode */
	if (inode->i_state & I_NEW ||
	    !(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DYNPERM))
		inode->i_mode = fattr->cf_mode;

Imagine that this file was changing owner, and was setuid. Don't we have a race here were a very lucky caller could get the entry from the dentry cache between the uid change and the permission change (setuid removal)?

The race is very narrow, and most of the worries are much more mundane, but isn't this why you would lock the inode for the whole update?

I'm not fully up on kernel locking rules, which is why I looked to NFS for the example I mentioned.

Thanks,

Andrew Bartlett

Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org
#8 lore raw
Quoted 73 lines · On Fri, 06 Jul 2012 16:20:47 +1000 Andrew Bartlett…
Quoted 47 lines · Jeff Layton
Quoted 37 lines · On Fri, 06 Jul 2012 09:31:07 +1000 Andrew Bartlett…
Quoted 36 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Quoted 6 lines
Quoted 2 lines

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Is it really safe to update so much without getting a lock over all the updates?

Quoted 5 lines

What's your worry, specifically?

The vfs only requires that you hold the lock over i_size updates. I suppose it's possible that you could have racing updates to an inode, but in practice, the last one will generally "win".

Writes are a worry, and I'm not sure I like the idea of parallel updates being able to leave it in a undefined state, but I was more worried about a read, that is someone reading just between:

	inode->i_uid = fattr->cf_uid;
	inode->i_gid = fattr->cf_gid;

and

	/* if dynperm is set, don't clobber existing mode */
	if (inode->i_state & I_NEW ||
	    !(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_DYNPERM))
		inode->i_mode = fattr->cf_mode;

Imagine that this file was changing owner, and was setuid. Don't we have a race here were a very lucky caller could get the entry from the dentry cache between the uid change and the permission change (setuid removal)?

Quoted 5 lines

The race is very narrow, and most of the worries are much more mundane, but isn't this why you would lock the inode for the whole update?

I'm not fully up on kernel locking rules, which is why I looked to NFS for the example I mentioned.

Locking only works if both "sides" actually respect the lock. The decision about how to handle setuid creds is done in prepare_binprm() and as far as I can tell, there is no lock held over the fetch of the i_mode and i_uid/i_gid.

I suppose it's possible there's a race there, but it would be for every filesystem -- not just CIFS and NFS. If you're concerned about this,
the thing to do there is probably to mail [email protected] with a description and see if it there's some mitigating factor we're
not seeing?

Another thing you could do is try to reproduce this. Maybe add a (switchable) delay after prepare_binprm() fetches the mode, but before it does the setuid checks. Try to run the program and then quickly change the ownership to something else and see if the setuid takes effect...

Signature · 1 line
Jeff Layton <[email protected]>
#9 lore raw
In reply to a message not in the archive
Quoted 32 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Quoted 6 lines

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Yes, same behaviour as as per my patch. Thanks you very much, it seems we are on our way to solving this!

Andrew Bartlett

Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org
#10 lore raw
Quoted 37 lines · On Fri, 06 Jul 2012 16:30:12 +1000 Andrew Bartlett…
Quoted 36 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Quoted 6 lines
Quoted 2 lines

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Yes, same behaviour as as per my patch. Thanks you very much, it seems we are on our way to solving this!

Thanks for testing it. I've gone ahead and sent that off to Steve for inclusion. If there is anything else required wrt serializing the inode attribute updates, then we can deal with that in a separate patch since that's really a separate problem.

Cheers,

Signature · 1 line
Jeff Layton <[email protected]>

A message that is not in the archive (sent off-list or not yet received): 20120706071123.2563c615-9yPaYZwiELC+kQycOl6kW4xkIHaj4LzF@public.gmane.org

#12 lore raw
Quoted 43 lines · Jeff Layton
Quoted 40 lines · On Fri, 06 Jul 2012 16:30:12 +1000 Andrew Bartlett…
Quoted 38 lines · Jeff Layton
Quoted 28 lines · On Thu, 05 Jul 2012 20:02:47 +1000 Andrew Bartlett…

(CCing in the original reporter)

Quoted 24 lines · Andrew Bartlett

When we do a readdir() in CIFS, we are potentially efficiently collecting a great deal of current, catchable stat information.

It is important that we always keep the dentry cache current for two reasons:
- the information may have changed (within the actime timeout).
- if we still have a dentry cache value after that timeout, it is quite
expensive (1xRTT per entry) to find out if it was still correct.

This hits folks who are using CIFS over a WAN very badly. For example on an emulated 50ms delay I would have ls --color complete in .1 seconds, and a second run take 4.5 seconds, as each stat() (for the colouring) would create a trans2 query_path_info query for each file, right after getting the same information in the trans2 find_first2.

This patch implements the simplest approach, I would welcome a correction on if there is a better approach than d_drop() and dput().

Tested on 3.4.4-3.cifsrevalidate.fc17.i686 with a 50ms WANem emulated WAN against Samba 4.0 beta3.

Thanks,

Andrew Bartlett

Nice work tracking that down and coding up the patch. While it's not incorrect to drop the dentry here, we can be a little more efficient here and just update the inode in place if the uniqueid didn't change.

Something like this (untested) patch should do it. Could you test this and let me know if it also helps?

Quoted 8 lines
Quoted 3 lines

Yes, same behaviour as as per my patch. Thanks you very much, it seems we are on our way to solving this!

Thanks for testing it. I've gone ahead and sent that off to Steve for inclusion. If there is anything else required wrt serializing the inode attribute updates, then we can deal with that in a separate patch since that's really a separate problem.

Indeed. Thanks!

Andrew Bartlett

Signature · 2 lines
Andrew Bartlett                                http://samba.org/~abartlet/
Authentication Developer, Samba Team           http://samba.org