netconsole fun
Subsystems (4)
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
I ask because it seems pretty difficult to get netconsole running even on a machine that has multiple physical interfaces, only one of which is slaved.
I scoured the documentation but didn't find anything relevant (does Documentation/networking/netconsole.txt need a patch?). AFAICT, the last discussion ended here back in June '11
http://lkml.indiana.edu/hypermail/linux/kernel/1106.1/03185.html with "Looks like we need to teach the tun-tap driver to support netpoll that shouldn't be too hard. I'll send up a patch shortly
Neil"
Any help or pointers provided would be much appreciated.
Regards,
Peter Hurley
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding state
Is there a way to control or associate network device names prior to udev renaming?
Thanks again,
Peter
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding state
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Neil
Quoted 8 lines
Thanks again,
Peter--
To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding state
Quoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
[ 3.840306] tg3.c:v3.127 (November 14, 2012) [ 3.873390] tg3 0000:08:00.0 eth0: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 3.873406] tg3 0000:08:00.0 eth0: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 3.873413] tg3 0000:08:00.0 eth0: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 3.873424] tg3 0000:08:00.0 eth0: dma_rwctrl[76180000] dma_mask[64-bit] ... [ 3.884239] 3c59x: Donald Becker and others. [ 3.884263] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000187cf80.
Regards,
Peter Hurley
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]
Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Neil
Quoted 13 lines
[ 3.840306] tg3.c:v3.127 (November 14, 2012) [ 3.873390] tg3 0000:08:00.0 eth0: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 3.873406] tg3 0000:08:00.0 eth0: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 3.873413] tg3 0000:08:00.0 eth0: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 3.873424] tg3 0000:08:00.0 eth0: dma_rwctrl[76180000] dma_mask[64-bit] ... [ 3.884239] 3c59x: Donald Becker and others. [ 3.884263] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000187cf80.Regards,
Peter Hurley
Quoted 71 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Quoted 1 line
Neil
Thanks for all your help here, Neil. Very much appreciated.
Happy Holidays,
Peter Hurley
Quoted 72 lines · Peter Hurley
Quoted 71 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Quoted 7 lines
Quoted 1 line
Neil
Thanks for all your help here, Neil. Very much appreciated.
Happy Holidays,
Peter Hurley
No problem, anytime!
Happy Holidays
Neil
Quoted 2 lines
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
Peter
-- >% --
Subject: [PATCH] netconsole: allow mac addr to specify local interface device
Allow the local interface device to be specified by ethernet MAC address. For example,
[email protected]/12:34:56:78:9a:bc,[email protected]/cb:a9:87:65:43:21
This alternate form enables netconsole to start and log boot messages even if the network device name varies (eg., a machine with multiple NICs).
--- Documentation/networking/netconsole.txt | 9 +++++++-- drivers/net/netconsole.c | 2 ++ include/linux/netpoll.h | 1 + net/core/netpoll.c | 19 +++++++++++++++++-- 4 files changed, 27 insertions(+), 4 deletions(-)
Documentation/networking/netconsole.txt +7 -2
@@ -23,12 +23,13 @@ Sender and receiver configuration: It takes a string configuration parameter "netconsole" in the following format: - netconsole=[src-port]@[src-ip]/[<dev>],[tgt-port]@<tgt-ip>/[tgt-macaddr] + netconsole=[src-port]@[src-ip]/[dev|macaddr],[tgt-port]@<tgt-ip>/[tgt-macaddr] where src-port source for UDP packets (defaults to 6665) src-ip source IP to use (interface address) - dev network interface (eth0) + dev|macaddr network interface (eth0) + alternate: ethernet MAC address of network interface tgt-port port for logging agent (6666) tgt-ip IP address for logging agent tgt-macaddr ethernet MAC address for logging agent (broadcast)
@@ -47,6 +48,10 @@ complete string enclosed in "quotes", thusly: modprobe netconsole netconsole="@/,@10.0.0.2/;@/eth1,[email protected]/" +The alternate form for specifying the local network interface with the +ethernet MAC address is useful when the device names are inconsistent from +boot to boot (eg., if the machine has multiple NICs). + Built-in netconsole starts immediately after the TCP stack is initialized and attempts to bring up the supplied dev at the supplied address.
drivers/net/netconsole.c +2 -0
@@ -180,6 +180,7 @@ static struct netconsole_target *alloc_param_target(char *target_config)strlcpy (nt->np.dev_name,"eth0" ,IFNAMSIZ ); nt->np.local_port =6665 ; nt->np.remote_port =6666 ; +memset (nt->np.local_mac,0 ,ETH_ALEN );memset (nt->np.remote_mac,0xff ,ETH_ALEN );/* Parse parameters and setup netpoll */
@@ -560,6 +561,7 @@ static struct config_item *make_netconsole_target(struct config_group *group,strlcpy (nt->np.dev_name,"eth0" ,IFNAMSIZ ); nt->np.local_port =6665 ; nt->np.remote_port =6666 ; +memset (nt->np.local_mac,0 ,ETH_ALEN );memset (nt->np.remote_mac,0xff ,ETH_ALEN );/* Initialize the config_item member */
include/linux/netpoll.h +1 -0
@@ -20,6 +20,7 @@ struct netpoll {__be32 local_ip, remote_ip;u16 local_port, remote_port; +u8 local_mac[ETH_ALEN ];u8 remote_mac[ETH_ALEN ];struct list_head rx;/* rx_np list element */
net/core/netpoll.c +17 -2
@@ -660,6 +660,7 @@ void netpoll_print_options(struct netpoll *np)np_info (np,"local port %d\n" , np->local_port);np_info (np,"local IP %pI4\n" , &np->local_ip);np_info (np,"interface '%s'\n" , np->dev_name); +np_info (np,"local ethernet address %pM\n" , np->local_mac);np_info (np,"remote port %d\n" , np->remote_port);np_info (np,"remote IP %pI4\n" , &np->remote_ip);np_info (np,"remote ethernet address %pM\n" , np->remote_mac);
@@ -693,7 +694,8 @@ int netpoll_parse_options(struct netpoll *np, char *opt)if ((delim =strchr (cur,',' )) ==NULL ) goto parse_failed; *delim =0 ; -strlcpy (np->dev_name, cur,sizeof (np->dev_name)); +if (!mac_pton (cur, np->local_mac)) +strlcpy (np->dev_name, cur,sizeof (np->dev_name)); cur = delim; } cur++;
@@ -806,8 +808,21 @@ int netpoll_setup(struct netpoll *np)struct in_device *in_dev;int err; -if (np->dev_name) +if (!is_zero_ether_addr (np->local_mac)) { +rcu_read_lock (); + ndev =dev_getbyhwaddr_rcu (&init_net,ARPHRD_ETHER , np->local_mac); +if (!ndev) { +rcu_read_unlock (); +np_err (np,"%pM doesn't exist, aborting\n" , np->local_mac); +return -ENODEV ; + } +dev_hold (ndev); +rcu_read_unlock (); +strlcpy (np->dev_name, ndev->name,IFNAMSIZ ); + + }else if (np->dev_name) ndev =dev_get_by_name (&init_net, np->dev_name); +if (!ndev) {np_err (np,"%s doesn't exist, aborting\n" , np->dev_name);return -ENODEV ;
Signature · 1 line
1.8.0.1
Quoted 8 lines · Peter Hurley
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 5 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
This is a good idea. Just that you need to complete the configfs interface too.
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
Peter
This looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Neil
P.S. Actually looking at it, I think it does one better, it lets you specify the destinaition netconsole address, and then dynamically looks up the routing table entry that gets you there, and uses the output device specified in the routing table.
http://www.cyberciti.biz/tips/linux-netconsole-log-management-tutorial.html
Quoted 88 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
Peter
Quoted 11 lines
This looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
I guess that leaves only the option of building in netconsole and the driver that supplies the interface.
Oh well.
Regards,
Peter
Quoted 101 lines · Peter Hurley
Quoted 88 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
PeterQuoted 11 lines
This looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Quoted 6 lines
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
I'm not sure what you mean by this. I get that other drivers are loaded and that if the netconsole service runs too soon, you might not have a network path to the netconsole host you want, but as long as the network is up, the service script (if properly written), shouldn't make you specify a network device. Instead of having to specify the device to the netconsole module directly, the config file for the service script lets you specify the destination ip address of the netconsole server, and figures out the output device based on the routing tables, whatever that device name happens to be on that boot. So you don't really need this patch, because user space can do this work (and more) for you. You just have to wait for the network to come up, which you need to do anyway.
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
Quoted 10 lines
I guess that leaves only the option of building in netconsole and the driver that supplies the interface.
Oh well.
Regards,
Peter
Quoted 102 lines · Neil Horman
Quoted 101 lines · Peter Hurley
Quoted 99 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
PeterThis looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Quoted 7 lines
Quoted 6 lines
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
I'm not sure what you mean by this.
This is the beginning of my netconsole log if I use userspace scripts to start it.
[ 19.125314] ip_tables: (C) 2000-2006 Netfilter Core Team [ 20.060925] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 21.829331] ip6_tables: (C) 2000-2006 Netfilter Core Team [ 25.728370] at-spi-registry[1862]: segfault at 18 ip 00007f6dd1dd45f1 sp 00007fff49bcd760 error 4 in libgconf-2.so.4.1.5[7f6dd1dbd000+2d000] [ 26.778848] EXT4-fs (dm-3): re-mounted. Opts: errors=remount-ro,commit=0 [ 30.643469] Bluetooth: RFCOMM TTY layer initialized [ 30.643509] Bluetooth: RFCOMM socket layer initialized [ 30.643512] Bluetooth: RFCOMM ver 1.11 [ 30.784550] Bluetooth: BNEP (Ethernet Emulation) ver 1.3 [ 30.784567] Bluetooth: BNEP filters: protocol multicast [ 30.784584] Bluetooth: BNEP socket layer initialized [ 34.010813] init: plymouth-stop pre-start process (2205) terminated with status 1
This is the beginning of my netconsole log if I am able to specify netconsole= options on the boot command line. Netconsole starts logging much earlier because it is much loaded earlier.
[ 8.764336] EXT4-fs (dm-4): mounted filesystem with ordered data mode. Opts: (null) [ 9.409379] firewire_core 0000:07:06.0: created device fw1: GUID 0800460301c2d69e, S400 [ 9.567395] init: ureadahead main process (500) terminated with status 5 [ 10.400338] Adding 10996456k swap on /dev/mapper/isw_cbdbfhdjad_Raid0p5. Priority:-1 extents:1 across:10996456k [ 10.496974] udevd[541]: starting version 173 [ 10.725906] EXT4-fs (dm-4): re-mounted. Opts: errors=remount-ro [ 11.288352] lp: driver loaded but no devices found [ 12.240058] parport_pc 00:05: reported by Plug and Play ACPI [ 12.240145] parport0: PC-style at 0x378 (0x778), irq 7, using FIFO [PCSPP,TRISTATE,COMPAT,ECP] [ 12.336161] lp0: using parport0 (interrupt-driven). [ 12.342867] microcode: CPU0 sig=0x10676, pf=0x40, revision=0x60f [ 12.436657] shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 [ 12.442245] ppdev: user-space parallel port driver [ 12.451592] net firewire0: IPv4 over IEEE 1394 on card 0000:07:06.0
Does that make more sense now?
Thanks again,
Peter
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
Just to be clear here,
Quoted 146 lines · Peter Hurley
Quoted 102 lines · Neil Horman
Quoted 101 lines · Peter Hurley
Quoted 99 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
PeterThis looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Quoted 7 lines
Quoted 6 lines
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
I'm not sure what you mean by this.
This is the beginning of my netconsole log if I use userspace scripts to start it.
[ 19.125314] ip_tables: (C) 2000-2006 Netfilter Core Team [ 20.060925] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 21.829331] ip6_tables: (C) 2000-2006 Netfilter Core Team [ 25.728370] at-spi-registry[1862]: segfault at 18 ip 00007f6dd1dd45f1 sp 00007fff49bcd760 error 4 in libgconf-2.so.4.1.5[7f6dd1dbd000+2d000] [ 26.778848] EXT4-fs (dm-3): re-mounted. Opts: errors=remount-ro,commit=0 [ 30.643469] Bluetooth: RFCOMM TTY layer initialized [ 30.643509] Bluetooth: RFCOMM socket layer initialized [ 30.643512] Bluetooth: RFCOMM ver 1.11 [ 30.784550] Bluetooth: BNEP (Ethernet Emulation) ver 1.3 [ 30.784567] Bluetooth: BNEP filters: protocol multicast [ 30.784584] Bluetooth: BNEP socket layer initialized [ 34.010813] init: plymouth-stop pre-start process (2205) terminated with status 1This is the beginning of my netconsole log if I am able to specify netconsole= options on the boot command line. Netconsole starts logging much earlier because it is much loaded earlier.
[ 8.764336] EXT4-fs (dm-4): mounted filesystem with ordered data mode. Opts: (null) [ 9.409379] firewire_core 0000:07:06.0: created device fw1: GUID 0800460301c2d69e, S400 [ 9.567395] init: ureadahead main process (500) terminated with status 5 [ 10.400338] Adding 10996456k swap on /dev/mapper/isw_cbdbfhdjad_Raid0p5. Priority:-1 extents:1 across:10996456k [ 10.496974] udevd[541]: starting version 173 [ 10.725906] EXT4-fs (dm-4): re-mounted. Opts: errors=remount-ro [ 11.288352] lp: driver loaded but no devices found [ 12.240058] parport_pc 00:05: reported by Plug and Play ACPI [ 12.240145] parport0: PC-style at 0x378 (0x778), irq 7, using FIFO [PCSPP,TRISTATE,COMPAT,ECP] [ 12.336161] lp0: using parport0 (interrupt-driven). [ 12.342867] microcode: CPU0 sig=0x10676, pf=0x40, revision=0x60f [ 12.436657] shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 [ 12.442245] ppdev: user-space parallel port driver [ 12.451592] net firewire0: IPv4 over IEEE 1394 on card 0000:07:06.0
Quoted 2 lines
Does that make more sense now?
No, actually, what exactly are you trying to show me here? I don't see any indication of netconsole doing anything in either of these log snippets. I'm also not sure why you're specifying netconsole options on the kernel command line at all.
Can you elaborate?
Neil
Quoted 15 lines
Thanks again,
PeterQuoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
Just to be clear here,
Quoted 147 lines · Neil Horman
Quoted 146 lines · Peter Hurley
Quoted 102 lines · Neil Horman
Quoted 101 lines · Peter Hurley
Quoted 99 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a recommended method of running netconsole on a machine that has a slaved device?
Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
PeterThis looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Quoted 7 lines
Quoted 6 lines
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
I'm not sure what you mean by this.
This is the beginning of my netconsole log if I use userspace scripts to start it.
[ 19.125314] ip_tables: (C) 2000-2006 Netfilter Core Team [ 20.060925] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 21.829331] ip6_tables: (C) 2000-2006 Netfilter Core Team [ 25.728370] at-spi-registry[1862]: segfault at 18 ip 00007f6dd1dd45f1 sp 00007fff49bcd760 error 4 in libgconf-2.so.4.1.5[7f6dd1dbd000+2d000] [ 26.778848] EXT4-fs (dm-3): re-mounted. Opts: errors=remount-ro,commit=0 [ 30.643469] Bluetooth: RFCOMM TTY layer initialized [ 30.643509] Bluetooth: RFCOMM socket layer initialized [ 30.643512] Bluetooth: RFCOMM ver 1.11 [ 30.784550] Bluetooth: BNEP (Ethernet Emulation) ver 1.3 [ 30.784567] Bluetooth: BNEP filters: protocol multicast [ 30.784584] Bluetooth: BNEP socket layer initialized [ 34.010813] init: plymouth-stop pre-start process (2205) terminated with status 1This is the beginning of my netconsole log if I am able to specify netconsole= options on the boot command line. Netconsole starts logging much earlier because it is much loaded earlier.
[ 8.764336] EXT4-fs (dm-4): mounted filesystem with ordered data mode. Opts: (null) [ 9.409379] firewire_core 0000:07:06.0: created device fw1: GUID 0800460301c2d69e, S400 [ 9.567395] init: ureadahead main process (500) terminated with status 5 [ 10.400338] Adding 10996456k swap on /dev/mapper/isw_cbdbfhdjad_Raid0p5. Priority:-1 extents:1 across:10996456k [ 10.496974] udevd[541]: starting version 173 [ 10.725906] EXT4-fs (dm-4): re-mounted. Opts: errors=remount-ro [ 11.288352] lp: driver loaded but no devices found [ 12.240058] parport_pc 00:05: reported by Plug and Play ACPI [ 12.240145] parport0: PC-style at 0x378 (0x778), irq 7, using FIFO [PCSPP,TRISTATE,COMPAT,ECP] [ 12.336161] lp0: using parport0 (interrupt-driven). [ 12.342867] microcode: CPU0 sig=0x10676, pf=0x40, revision=0x60f [ 12.436657] shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 [ 12.442245] ppdev: user-space parallel port driver [ 12.451592] net firewire0: IPv4 over IEEE 1394 on card 0000:07:06.0
Quoted 4 lines
Quoted 2 lines
Does that make more sense now?
No, actually, what exactly are you trying to show me here? I don't see any indication of netconsole doing anything in either of these log snippets.
^^^^^^^^^^^^^^^^^^^^^^
except that it was netconsole that wrote these logs
Note the log times.
In the first log, which is from a netconsole loaded by userspace scripts, the first printk it logs isn't until 19.125314 secs into boot. Most kernel + module init has already happened by this time.
In the second log, which is from a netconsole (still built as a module) loaded as a result of using the boot command line. It starts logging at 8.764336 secs into boot -- almost 10 secs earlier than using userspace scripting to load netconsole.
Quoted 4 lines
I'm
also not sure why you're specifying netconsole options on the kernel command line at all.
Can you elaborate?
Specifying netconsole= on the boot command line loads the netconsole module at the earliest possible time (and much earlier than scripting will do). And also leaves it as an optional configuration (at least for me it does since I use grub2 and can edit the boot command line before booting).
AFAIK, there are 5 ways to load netconsole:
1. On the boot command line with netconsole=
If netconsole is built-in, this is the only way to initialize it. If netconsole is a module, this forces netconsole to load at the earliest possible time.
2. Via /etc/modules
This happens before network device renaming, so suffers from the problems we've been discussing.
3. Via a custom udev rule in /etc/udev/rules.d/
Earliest userspace method to modprobe netconsole and can be used after device renaming, but is still fairly late in the boot process.
4. Via init/service scripting
5. At the user shell
AFAIK, there are 4 ways to specify the necessary options to netconsole:
a. On the boot command line with netconsole=
Also loads netconsole
b. In a .conf file in /etc/modprobe.d
c. On the modprobe command line
d. Via configfs
Regards,
Peter
Quoted 191 lines · Peter Hurley
Quoted 147 lines · Neil Horman
Quoted 146 lines · Peter Hurley
Quoted 102 lines · Neil Horman
Quoted 101 lines · Peter Hurley
Quoted 99 lines · Neil Horman
Quoted 79 lines · Peter Hurley
Quoted 63 lines · Neil Horman
Quoted 58 lines · Peter Hurley
Quoted 30 lines · Neil Horman
Quoted 29 lines · Peter Hurley
Quoted 7 lines · Cong Wang
Quoted 4 lines · Peter Hurley
Now that netpoll has been disabled for slaved devices, is there a
recommended method of running netconsole on a machine that has a slaved
device?Yes, running it on the master device instead.
Thanks for the suggestion, but:
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/br0,[email protected]/xx:xx:xx:xx:xx:xx ... [ 5.289869] netpoll: netconsole: local port 6665 [ 5.289885] netpoll: netconsole: local IP 192.168.10.99 [ 5.289892] netpoll: netconsole: interface 'br0' [ 5.289898] netpoll: netconsole: remote port 30000 [ 5.289907] netpoll: netconsole: remote IP 192.168.10.100 [ 5.289914] netpoll: netconsole: remote ethernet address xx:xx:xx:xx:xx:xx [ 5.289922] netpoll: netconsole: br0 doesn't exist, aborting [ 5.289929] netconsole: cleaning up ... [ 9.392291] Bridge firewalling registered [ 9.396805] device eth1 entered promiscuous mode [ 9.418350] eth1: setting full-duplex. [ 9.421268] br0: port 1(eth1) entered forwarding state [ 9.423354] br0: port 1(eth1) entered forwarding stateQuoted 7 lines
Quoted 3 lines
Is there a way to control or associate network device names prior to udev renaming?
That looks like a systemd problem (or more specifically a boot dependency problem). You need to modify your netconsole unit/service file to start after all your networking is up. NetworkManager provides a dummy service file for this purpose, called networkmanager-wait-online.service
Ok. So with a single physical network interface that will be bridged, netconsole cannot used for kernel boot messages.
With a machine with multiple nics, is there a way to control device naming so that the interface name to be used by netconsole specified on the boot command line will actually corresponding to the intended device. For example,
[ 0.000000] Kernel command line: BOOT_IMAGE=/boot/vmlinuz-3.7.0-rc8-xeon ...... [email protected]/eth0,[email protected]/xx:xx:xx:xx:xx:xx .... [ 4.092184] 3c59x: Donald Becker and others. [ 4.092204] 0000:07:05.0: 3Com PCI 3c905C Tornado at ffffc9000186cf80. [ 4.094035] tg3.c:v3.125 (September 26, 2012) .... [ 4.125038] tg3 0000:08:00.0 eth1: Tigon3 [partno(BCM95754) rev b002] (PCI Express) MAC address xx:xx:xx:xx:xx:xx [ 4.125055] tg3 0000:08:00.0 eth1: attached PHY is 5787 (10/100/1000Base-T Ethernet) (WireSpeed[1], EEE[0]) [ 4.125062] tg3 0000:08:00.0 eth1: RXcsums[1] LinkChgREG[0] MIirq[0] ASF[0] TSOcap[1] [ 4.125068] tg3 0000:08:00.0 eth1: dma_rwctrl[76180000] dma_mask[64-bit]Quoted 4 lines
This is attaching netconsole to the wrong device because bus enumeration, and therefore load order, is not consistent from boot to boot.
Quoted 7 lines
No, theres no way to do that. As you note device ennumeration isn't consistent accross boots, thats why udev creates rules to rename devices based on immutable (or semi-immutable) data, like mac addresses, or pci bus locations). Once that happens, you'll have consistent names for your interfaces, and that work will be guaranteed to be done after networkmanager has finished opening all the interfaces that it needs (hence my suggestion to make netconsole service dependent on networkmanager service startup completing).
Just wondering if you think something like the patch below is suitable/acceptable for insulating netconsole from inconsistent device name scenarios without changing the existing semantics. The basic idea is to allow an ethernet MAC address in the <dev> field of the netconsole= options, and if a MAC address was specified rather than a device name, to do the dev lookup from the MAC address instead.
Quoted 8 lines
This doesn't extend to, but also doesn't interfere with, the dynamic config of netconsole via configfs.
Would you mind reviewing it?
Regards,
PeterThis looks like a pretty good idea to me. That said, something occured to me when you wrote your summary above. Have you looked at the netconsole service scripts that most distros provide in their packaging? I'm almost positive Red Hat/Fedora (and also like Suse and Ubuntu), already implement this functionality from user space. Basically, instead of people just modprobing netconsole, they create a service script that parses a config file that has contains all the options needed to load the netconsole module, and it has the intellegence to see if you specified a mac address rather than a device. If you did that it finds the corresponding device mac address and uses that as the device. I'm sorry, I don't know why I didn't think of that before. Check that out though, that will likey give you exactly what you need
Quoted 7 lines
Quoted 6 lines
Even with a udev rule to load netconsole that runs immediately after device renaming (so before scripting), most of the dynamic module loading has already happened so netconsole misses it. At least with the patch, netconsole will load and attach to the proper interface much earlier in the boot so that module-load-time messages will be caught.
I'm not sure what you mean by this.
This is the beginning of my netconsole log if I use userspace scripts to start it.
[ 19.125314] ip_tables: (C) 2000-2006 Netfilter Core Team [ 20.060925] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 21.829331] ip6_tables: (C) 2000-2006 Netfilter Core Team [ 25.728370] at-spi-registry[1862]: segfault at 18 ip 00007f6dd1dd45f1 sp 00007fff49bcd760 error 4 in libgconf-2.so.4.1.5[7f6dd1dbd000+2d000] [ 26.778848] EXT4-fs (dm-3): re-mounted. Opts: errors=remount-ro,commit=0 [ 30.643469] Bluetooth: RFCOMM TTY layer initialized [ 30.643509] Bluetooth: RFCOMM socket layer initialized [ 30.643512] Bluetooth: RFCOMM ver 1.11 [ 30.784550] Bluetooth: BNEP (Ethernet Emulation) ver 1.3 [ 30.784567] Bluetooth: BNEP filters: protocol multicast [ 30.784584] Bluetooth: BNEP socket layer initialized [ 34.010813] init: plymouth-stop pre-start process (2205) terminated with status 1This is the beginning of my netconsole log if I am able to specify netconsole= options on the boot command line. Netconsole starts logging much earlier because it is much loaded earlier.
[ 8.764336] EXT4-fs (dm-4): mounted filesystem with ordered data mode. Opts: (null) [ 9.409379] firewire_core 0000:07:06.0: created device fw1: GUID 0800460301c2d69e, S400 [ 9.567395] init: ureadahead main process (500) terminated with status 5 [ 10.400338] Adding 10996456k swap on /dev/mapper/isw_cbdbfhdjad_Raid0p5. Priority:-1 extents:1 across:10996456k [ 10.496974] udevd[541]: starting version 173 [ 10.725906] EXT4-fs (dm-4): re-mounted. Opts: errors=remount-ro [ 11.288352] lp: driver loaded but no devices found [ 12.240058] parport_pc 00:05: reported by Plug and Play ACPI [ 12.240145] parport0: PC-style at 0x378 (0x778), irq 7, using FIFO [PCSPP,TRISTATE,COMPAT,ECP] [ 12.336161] lp0: using parport0 (interrupt-driven). [ 12.342867] microcode: CPU0 sig=0x10676, pf=0x40, revision=0x60f [ 12.436657] shpchp: Standard Hot Plug PCI Controller Driver version: 0.4 [ 12.442245] ppdev: user-space parallel port driver [ 12.451592] net firewire0: IPv4 over IEEE 1394 on card 0000:07:06.0Quoted 4 lines
Quoted 2 lines
Does that make more sense now?
No, actually, what exactly are you trying to show me here? I don't see any indication of netconsole doing anything in either of these log snippets.
^^^^^^^^^^^^^^^^^^^^^^
except that it was netconsole that wrote these logsNote the log times.
In the first log, which is from a netconsole loaded by userspace scripts, the first printk it logs isn't until 19.125314 secs into boot. Most kernel + module init has already happened by this time.
In the second log, which is from a netconsole (still built as a module) loaded as a result of using the boot command line. It starts logging at 8.764336 secs into boot -- almost 10 secs earlier than using userspace scripting to load netconsole.
Quoted 4 lines
I'm
also not sure why you're specifying netconsole options on the kernel command line at all.
Can you elaborate?Specifying netconsole= on the boot command line loads the netconsole module at the earliest possible time (and much earlier than scripting will do). And also leaves it as an optional configuration (at least for me it does since I use grub2 and can edit the boot command line before booting).
AFAIK, there are 5 ways to load netconsole:
1. On the boot command line with netconsole=
If netconsole is built-in, this is the only way to initialize it. If netconsole is a module, this forces netconsole to load at the earliest possible time.
2. Via/etc/modules
This happens before network device renaming, so suffers from the problems we've been discussing.
3. Via a custom udev rule in/etc/udev/rules.d/
Earliest userspace method to modprobe netconsole and can be used after device renaming, but is still fairly late in the boot process.
4. Via init/service scripting
5. At the user shell
Quoted 7 lines
AFAIK, there are 4 ways to specify the necessary options to netconsole:
a. On the boot command line with netconsole=
Also loads netconsole
b. In a .conf file in/etc/modprobe.d
c. On the modprobe command line
d. Via configfs
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script. If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
Neil
Quoted 10 lines
Regards,
Peter--
To unsubscribe from this list: send the line "unsubscribe netdev" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Quoted 3 lines · Neil Horman
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script.
Well, it's both but I should have been clearer here. Sorry about that.
Quoted 6 lines
If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
When I get some more free time I'll experiment with this approach.
Just to clarify something from earlier in the discussion:
Quoted 1 line · Neil Horman
On Thu, Dec 13, 2012 at 09:49:31AM -0500, Peter Hurley wrote:
....
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
The breakage is a normal consequence of being able to load netconsole before the udev rules that do device renaming. The same thing would happen modifying initramfs.
Basically, once netconsole attaches to a device, that device cannot be renamed. Unfortunately, the default udev behavior messes things up further because it will try to do this:
eth0->eth1
eth1->eth0
which means neither device will be renamed.
Maybe the net core should just implement persistent device names ;)
Thanks again for all your time,
Peter Hurley
Quoted 32 lines · Peter Hurley
Quoted 3 lines · Neil Horman
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script.
Well, it's both but I should have been clearer here. Sorry about that.
Quoted 6 lines
If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
When I get some more free time I'll experiment with this approach.
Just to clarify something from earlier in the discussion:
Quoted 1 line · Neil Horman
On Thu, Dec 13, 2012 at 09:49:31AM -0500, Peter Hurley wrote:
....
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
The breakage is a normal consequence of being able to load netconsole before the udev rules that do device renaming. The same thing would happen modifying initramfs.
Quoted 9 lines
Basically, once netconsole attaches to a device, that device cannot be renamed. Unfortunately, the default udev behavior messes things up further because it will try to do this:
eth0->eth1
eth1->eth0
which means neither device will be renamed.Maybe the net core should just implement persistent device names ;)
Theres no good way for the kernel to do that, as persistent naming in this case is a matter of user policy, not kernel hardware management (i.e. do you want a network name to follow a mac address, a pci slot, or the network its connected to)? You can use smbios to get some modicum of persistent device naming currently, but I don't recall if that requires udev rules to implement as well
You're best bet is to simply make your initramfs more robust. I understand what you're saying regarding renaming after you've taken a reference on a device not being possible, but you can run udev within the initramfs, and do your renaming prior to your netconsole load.
Thanks
Neil
Quoted 4 lines
Thanks again for all your time,
Peter Hurley
Quoted 48 lines · Neil Horman
Quoted 32 lines · Peter Hurley
Quoted 3 lines · Neil Horman
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script.
Well, it's both but I should have been clearer here. Sorry about that.
Quoted 6 lines
If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
When I get some more free time I'll experiment with this approach.
Just to clarify something from earlier in the discussion:
Quoted 1 line · Neil Horman
On Thu, Dec 13, 2012 at 09:49:31AM -0500, Peter Hurley wrote:
....
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
The breakage is a normal consequence of being able to load netconsole before the udev rules that do device renaming. The same thing would happen modifying initramfs.
Quoted 9 lines
Basically, once netconsole attaches to a device, that device cannot be renamed. Unfortunately, the default udev behavior messes things up further because it will try to do this:
eth0->eth1
eth1->eth0
which means neither device will be renamed.Maybe the net core should just implement persistent device names ;)
Theres no good way for the kernel to do that, as persistent naming in this case is a matter of user policy, not kernel hardware management (i.e. do you want a network name to follow a mac address, a pci slot, or the network its connected to)? You can use smbios to get some modicum of persistent device naming currently, but I don't recall if that requires udev rules to implement as well
Quoted 4 lines
You're best bet is to simply make your initramfs more robust. I understand what you're saying regarding renaming after you've taken a reference on a device not being possible, but you can run udev within the initramfs, and do your renaming prior to your netconsole load.
Hi Neil,
I plan to re-submit 'netconsole: allow mac addr to specify local interface device' which you originally objected to because you asserted that the same effect could be obtained through udev scripts in the initramfs.
When you shot down this patch, did you actually try what you suggested in the initramfs or were you just hypothesizing that it would possible?
Regards,
Peter Hurley
Quoted 56 lines · Peter Hurley
Quoted 48 lines · Neil Horman
Quoted 32 lines · Peter Hurley
Quoted 3 lines · Neil Horman
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script.
Well, it's both but I should have been clearer here. Sorry about that.
Quoted 6 lines
If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
When I get some more free time I'll experiment with this approach.
Just to clarify something from earlier in the discussion:
Quoted 1 line · Neil Horman
On Thu, Dec 13, 2012 at 09:49:31AM -0500, Peter Hurley wrote:
....
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
The breakage is a normal consequence of being able to load netconsole before the udev rules that do device renaming. The same thing would happen modifying initramfs.
Quoted 9 lines
Basically, once netconsole attaches to a device, that device cannot be renamed. Unfortunately, the default udev behavior messes things up further because it will try to do this:
eth0->eth1
eth1->eth0
which means neither device will be renamed.Maybe the net core should just implement persistent device names ;)
Theres no good way for the kernel to do that, as persistent naming in this case is a matter of user policy, not kernel hardware management (i.e. do you want a network name to follow a mac address, a pci slot, or the network its connected to)? You can use smbios to get some modicum of persistent device naming currently, but I don't recall if that requires udev rules to implement as well
Quoted 4 lines
You're best bet is to simply make your initramfs more robust. I understand what you're saying regarding renaming after you've taken a reference on a device not being possible, but you can run udev within the initramfs, and do your renaming prior to your netconsole load.
Hi Neil,
Quoted 8 lines
I plan to re-submit 'netconsole: allow mac addr to specify local interface device' which you originally objected to because you asserted that the same effect could be obtained through udev scripts in the initramfs.
When you shot down this patch, did you actually try what you suggested in the initramfs or were you just hypothesizing that it would possible?
I've not tried specifically what want to do, no, but I've done interface renaming plenty of times in the initramfs back when I did kdump work (we had to rename devices in the initramfs to align them with whatever udev renamed them to once we pivot_root-ed to the rootfs).
I presume you're sending me this note because you've for some reason decided that doing this in the initramfs isn't feasible? I'm happy to help you through it if you like.
You're also welcome to resubmit your patch, but you're going to have to justify why doing this in user space isn't a sufficient solution.
Regards
Neil
Quoted 5 lines · Neil Horman
I've not tried specifically what want to do, no, but I've done interface renaming plenty of times in the initramfs back when I did kdump work (we had to rename devices in the initramfs to align them with whatever udev renamed them to once we pivot_root-ed to the rootfs).
The new kdump infrastructure which uses dracut already switches to udev completely, it has some rule file to map mac address to its name.
Quoted 65 lines · Neil Horman
Quoted 56 lines · Peter Hurley
Quoted 48 lines · Neil Horman
Quoted 32 lines · Peter Hurley
Quoted 3 lines · Neil Horman
Ah! I'm sorry, I didn't realize this was really about getting netconsole up early in the boot, rather than just getting it up robustly using the startup script.
Well, it's both but I should have been clearer here. Sorry about that.
Quoted 6 lines
If thats the case, then I would recommend that you modify the initramfs to do something simmilar to the startup script (since thats where the netconsole module will get loaded anyway). You can write a script there that will let you specify the destination ip address and figure out the output dev based on the routing tables. If you're using dracut to build your initramfs, then this should be pretty straightforward.
When I get some more free time I'll experiment with this approach.
Just to clarify something from earlier in the discussion:
Quoted 1 line · Neil Horman
On Thu, Dec 13, 2012 at 09:49:31AM -0500, Peter Hurley wrote:
....
Quoted 6 lines
Quoted 4 lines
There is an unforeseen consequence of the patch: it breaks device renaming because the device will already be in use by netconsole. Which is the whole problem with userspace device renaming to begin with...
That is bad, but see above, the netconsole service can work around this for you, allowing you to never have to specify a particular device at all.
The breakage is a normal consequence of being able to load netconsole before the udev rules that do device renaming. The same thing would happen modifying initramfs.
Quoted 9 lines
Basically, once netconsole attaches to a device, that device cannot be renamed. Unfortunately, the default udev behavior messes things up further because it will try to do this:
eth0->eth1 eth1->eth0which means neither device will be renamed.
Maybe the net core should just implement persistent device names ;)
Theres no good way for the kernel to do that, as persistent naming in this case is a matter of user policy, not kernel hardware management (i.e. do you want a network name to follow a mac address, a pci slot, or the network its connected to)? You can use smbios to get some modicum of persistent device naming currently, but I don't recall if that requires udev rules to implement as well
Quoted 4 lines
You're best bet is to simply make your initramfs more robust. I understand what you're saying regarding renaming after you've taken a reference on a device not being possible, but you can run udev within the initramfs, and do your renaming prior to your netconsole load.
Hi Neil,
Quoted 8 lines
I plan to re-submit 'netconsole: allow mac addr to specify local interface device' which you originally objected to because you asserted that the same effect could be obtained through udev scripts in the initramfs.
When you shot down this patch, did you actually try what you suggested in the initramfs or were you just hypothesizing that it would possible?
Quoted 8 lines
I've not tried specifically what want to do, no, but I've done interface renaming plenty of times in the initramfs back when I did kdump work (we had to rename devices in the initramfs to align them with whatever udev renamed them to once we pivot_root-ed to the rootfs).
I presume you're sending me this note because you've for some reason decided that doing this in the initramfs isn't feasible? I'm happy to help you through it if you like.
Neil,
I owe you an apology.
Performing the udev device renaming and modprobing netconsole with the renamed device interface is indeed possible within initramfs. Once I had managed to get udev device renaming working in the initramfs, I had confused myself regarding which interface went with which MAC address.
Have a good weekend.
Regards,
Peter Hurley