Skip to contentSkip to conversation

regulator: core: allow consumers to request to closes step voltage

RFC PATCH In review Nishanth Menon 2 participants 7 messages Jun 19, 2013 – Jun 21, 2013

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

RFC PATCH 1/1 regulator: core: allow consumers to request to closes step voltage

Regulator consumers are not aware of the characteristics of regulator used to supply. For example:
consumerX requests for voltage min_uV = 500mV, max_uV = 500mV On a regulator which has a step size of 10mV, this can be exactly achieved.

However, on a regulator which is non-exact divider step size (example 12.66mV step size), the closest achievable would be 506.4. regulator_set_voltage_tol does not work out either as <500mV is not an operational voltage.

Account for step size accuracy when exact voltage requests are send for step based regulators.

---
The specific example I faced was using cpufreq-cpu0 driver with voltages for OPPs for MPU rail and attempting the common definitions against voltages that are non-exact multiples of stepsize of PMIC.

The alternative would be implement custom set_voltage (as againsta simpler set_voltage_sel and using linear map/list functions) for the regulator which will account for the same.

Yet another alternative might be to introduce yet another custom function similar to regulator_set_voltage_tol which accounts for this. something like:
regulator_set_voltage_floor(regulator, voltage, tol) or something to that effect.

 drivers/regulator/core.c |    3 +++
 1 file changed, 3 insertions(+)
drivers/regulator/core.c +3 -0
index 288c75a..98c96b2 100644
@@ -2407,6 +2407,9 @@ static int _regulator_do_set_voltage(struct regulator_dev *rdev,
 		}
 
 	} else if (rdev->desc->ops->set_voltage_sel) {
+		if (min_uV == max_uV && rdev->desc->uV_step)
+			max_uV += rdev->desc->uV_step;
+
 		if (rdev->desc->ops->map_voltage) {
 			ret = rdev->desc->ops->map_voltage(rdev, min_uV,
 							   max_uV);
Signature · 1 line
1.7.9.5
maintainer
#1 lore raw
Quoted 2 lines · Nishanth Menon

Account for step size accuracy when exact voltage requests are send for step based regulators.

If the consumer can tolerate a different voltage why not just request the range that can be tolerated? Your problem here is specifying an exact voltage.

Quoted 11 lines

The specific example I faced was using cpufreq-cpu0 driver with voltages for OPPs for MPU rail and attempting the common definitions against voltages that are non-exact multiples of stepsize of PMIC.

The alternative would be implement custom set_voltage (as againsta simpler set_voltage_sel and using linear map/list functions) for the regulator which will account for the same.

Yet another alternative might be to introduce yet another custom function similar to regulator_set_voltage_tol which accounts for this. something like:
regulator_set_voltage_floor(regulator, voltage, tol) or something to that effect.

Or as I keep telling you guys the consumer can just do that directly using the existing API; the whole point in specifying the voltage as a range is to allow the consumer to cope with arbatrary regulators by giving a range of voltages that it can accept.

The API is deliberately very conservative in these matters since there is a danger of physical damage if things really go wrong in some applications, it makes sure that both the drivers and the system integration are involved.

#2 lore raw
Quoted 8 lines · Mark Brown
Quoted 2 lines · Nishanth Menon

Account for step size accuracy when exact voltage requests are send for step based regulators.

If the consumer can tolerate a different voltage why not just request the range that can be tolerated? Your problem here is specifying an exact voltage.

I think you mean using regulator_get_linear_step

Quoted 18 lines
Quoted 5 lines

The specific example I faced was using cpufreq-cpu0 driver with voltages for OPPs for MPU rail and attempting the common definitions against voltages that are non-exact multiples of stepsize of PMIC.

Quoted 7 lines

The alternative would be implement custom set_voltage (as againsta simpler set_voltage_sel and using linear map/list functions) for the regulator which will account for the same.

Yet another alternative might be to introduce yet another custom function similar to regulator_set_voltage_tol which accounts for this. something like:
regulator_set_voltage_floor(regulator, voltage, tol) or something to that effect.

Or as I keep telling you guys the consumer can just do that directly using the existing API; the whole point in specifying the voltage as a range is to allow the consumer to cope with arbatrary regulators by giving a range of voltages that it can accept.

Quoted 4 lines

The API is deliberately very conservative in these matters since there is a danger of physical damage if things really go wrong in some applications, it makes sure that both the drivers and the system integration are involved.

I agree. The intent of this series was to start a conversation to see if we can make it simpler.

Searching for the users of regulator_get_linear_step in 3.10-rc6 shows none.

For a generic driver which needs to handle platforms which have tolerance, they'd use regulator_set_voltage_tol. But the implementation would allow for uV - tol to uV + tol as range, which in the case I mentioned(min voltage =uV) wont work.

If the consumer wants to be aware of linear step regulator, they'd have to do:
step_uV = regulator_get_linear_step(...); regulator_set_voltage(uV, uV + step_uV);

Then this wont handle tolerance. So the solution seems to be (for the consumer):
step_uV = regulator_get_linear_step(...);
..
if (tol)

	regulator_set_voltage_tol(uV, tol);
else
	regulator_set_voltage(uV, uV + step_uV);

(with the required error checks for regulator being a linear regulator
etc..).

At least to me, there is no sane manner to handle "tolerance" and linear step accuracy for a defined voltage (Should tolerance be rounded off to step_uV? what about the border cases etc.)

Would you agree?

Signature · 5 lines
Regards,
Nishanth Menon

PS: Since I just looped in cpufreq list, discussion thread:
http://marc.info/?t=137166954900005&r=1&w=2
#3 lore raw
Quoted 56 lines · Nishanth Menon
Quoted 8 lines · Mark Brown
Quoted 2 lines · Nishanth Menon

Account for step size accuracy when exact voltage requests are send for step based regulators.

If the consumer can tolerate a different voltage why not just request the range that can be tolerated? Your problem here is specifying an exact voltage.

I think you mean using regulator_get_linear_step

Quoted 18 lines
Quoted 5 lines

The specific example I faced was using cpufreq-cpu0 driver with voltages for OPPs for MPU rail and attempting the common definitions against voltages that are non-exact multiples of stepsize of PMIC.

Quoted 7 lines

The alternative would be implement custom set_voltage (as againsta simpler set_voltage_sel and using linear map/list functions) for the regulator which will account for the same.

Yet another alternative might be to introduce yet another custom function similar to regulator_set_voltage_tol which accounts for this. something like:
regulator_set_voltage_floor(regulator, voltage, tol) or something to that effect.

Or as I keep telling you guys the consumer can just do that directly using the existing API; the whole point in specifying the voltage as a range is to allow the consumer to cope with arbatrary regulators by giving a range of voltages that it can accept.

Quoted 4 lines

The API is deliberately very conservative in these matters since there is a danger of physical damage if things really go wrong in some applications, it makes sure that both the drivers and the system integration are involved.

I agree. The intent of this series was to start a conversation to see if we can make it simpler.

Searching for the users of regulator_get_linear_step in 3.10-rc6 shows none.

For a generic driver which needs to handle platforms which have tolerance, they'd use regulator_set_voltage_tol. But the implementation would allow for uV - tol to uV + tol as range, which in the case I mentioned(min voltage =uV) wont work.

If the consumer wants to be aware of linear step regulator, they'd have to do:
step_uV = regulator_get_linear_step(...); regulator_set_voltage(uV, uV + step_uV);

Then this wont handle tolerance. So the solution seems to be (for the consumer):
step_uV = regulator_get_linear_step(...);
..
if (tol)

	regulator_set_voltage_tol(uV, tol);
else
	regulator_set_voltage(uV, uV + step_uV);
Quoted 8 lines

(with the required error checks for regulator being a linear regulator
etc..).

At least to me, there is no sane manner to handle "tolerance" and linear step accuracy for a defined voltage (Should tolerance be rounded off to step_uV? what about the border cases etc.)

Would you agree?

Here is an RFC for the same. My hope was to see if something simpler could be done.
From cb9830191cb9b8021e50bcda25d110b4b9a7dbd3 Mon Sep 17 00:00:00 2001
From: Nishanth Menon <[email protected]>
Date: Thu, 20 Jun 2013 16:37:30 -0500
Subject: [RFC PATCH] cpufreq: cpufreq-cpu0: account for regulator step size
accuracy

Generic regulator consumers such as cpufreq-cpu0 are not aware of the characteristics of regulator used to supply. For example:
consumerX requests for voltage min_uV = 500mV, max_uV = 500mV On a regulator which has a step size of 10mV, this can be exactly achieved.

However, on a regulator which is non-exact divider step size (example 12.66mV step size), the closest achievable would be 506.4. regulator_set_voltage_tol does not work out either as <500mV is not an acceptable operational voltage.

Account for step size accuracy when exact voltage requests are send for step based regulators.

---
 drivers/cpufreq/cpufreq-cpu0.c |   28 ++++++++++++++++++++++++----
 1 file changed, 24 insertions(+), 4 deletions(-)
drivers/cpufreq/cpufreq-cpu0.c +24 -4
index ad1fde2..707565c 100644
@@ -28,6 +28,7 @@ static struct device *cpu_dev;
 static struct clk *cpu_clk;
 static struct regulator *cpu_reg;
 static struct cpufreq_frequency_table *freq_table;
+static int cpu_reg_step_size;
 
 static int cpu0_verify_speed(struct cpufreq_policy *policy)
 {
@@ -91,7 +92,12 @@ static int cpu0_set_target(struct cpufreq_policy *policy,
 
 	/* scaling up?  scale voltage before frequency */
 	if (cpu_reg && freqs.new > freqs.old) {
-		ret = regulator_set_voltage_tol(cpu_reg, volt, tol);
+		if (tol)
+			ret = regulator_set_voltage_tol(cpu_reg, volt, tol);
+		else
+			ret = regulator_set_voltage(cpu_reg, volt,
+						    volt + cpu_reg_step_size);
+
 		if (ret) {
 			pr_err("failed to scale voltage up: %d\n", ret);
 			freqs.new = freqs.old;
@@ -102,15 +108,28 @@ static int cpu0_set_target(struct cpufreq_policy *policy,
 	ret = clk_set_rate(cpu_clk, freq_exact);
 	if (ret) {
 		pr_err("failed to set clock rate: %d\n", ret);
-		if (cpu_reg)
-			regulator_set_voltage_tol(cpu_reg, volt_old, tol);
+		if (cpu_reg) {
+			if (tol)
+				ret = regulator_set_voltage_tol(cpu_reg,
+								volt_old,
+								tol);
+			else
+				ret = regulator_set_voltage(cpu_reg,
+							    volt_old,
+							    volt_old +
+							    cpu_reg_step_size);
+		}
 		freqs.new = freqs.old;
 		goto post_notify;
 	}
 
 	/* scaling down?  scale voltage after frequency */
 	if (cpu_reg && freqs.new < freqs.old) {
-		ret = regulator_set_voltage_tol(cpu_reg, volt, tol);
+		if (tol)
+			ret = regulator_set_voltage_tol(cpu_reg, volt, tol);
+		else
+			ret = regulator_set_voltage(cpu_reg, volt,
+						    volt + cpu_reg_step_size);
 		if (ret) {
 			pr_err("failed to scale voltage down: %d\n", ret);
 			clk_set_rate(cpu_clk, freqs.old * 1000);
@@ -260,6 +279,7 @@ static int cpu0_cpufreq_probe(struct platform_device *pdev)
 		ret = regulator_set_voltage_time(cpu_reg, min_uV, max_uV);
 		if (ret > 0)
 			transition_latency += ret * 1000;
+		cpu_reg_step_size = regulator_get_linear_step(cpu_reg);
 	}
 
 	ret = cpufreq_register_driver(&cpu0_cpufreq_driver);
Signature · 6 lines
1.7.9.5


-- 
Regards,
Nishanth Menon
maintainer
#4 lore raw
In reply to Nishanth Menon
Quoted 7 lines · Nishanth Menon
Quoted 3 lines · Mark Brown

If the consumer can tolerate a different voltage why not just request the range that can be tolerated? Your problem here is specifying an exact voltage.

I think you mean using regulator_get_linear_step

No, I don't. Why would that make sense? It limits the regulators that can be used and the properties of the regulator have no impact on what the SoC can support.

Quoted 7 lines
Quoted 4 lines

Or as I keep telling you guys the consumer can just do that directly using the existing API; the whole point in specifying the voltage as a range is to allow the consumer to cope with arbatrary regulators by giving a range of voltages that it can accept.

I agree. The intent of this series was to start a conversation to see if we can make it simpler.

It's already very simple. The consumer driver just needs to supply the list of voltages which it can accept, that's all.

Quoted 4 lines

For a generic driver which needs to handle platforms which have tolerance, they'd use regulator_set_voltage_tol. But the implementation would allow for uV - tol to uV + tol as range, which in the case I mentioned(min voltage =uV) wont work.

So just write it as an explicit voltage range then. For example many devices can tolerate any supply up to the maximum rated supply at any frequency so just specify that as the upper limit.

Quoted 3 lines

If the consumer wants to be aware of linear step regulator, they'd have to do:
step_uV = regulator_get_linear_step(...); regulator_set_voltage(uV, uV + step_uV);

No, the consumer really doesn't want to be aware of linear step regulators. Why would it care that there even are linear steps? If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem

#5 lore raw
Quoted 37 lines · Mark Brown
Quoted 7 lines · Nishanth Menon
Quoted 3 lines · Mark Brown

If the consumer can tolerate a different voltage why not just request the range that can be tolerated? Your problem here is specifying an exact voltage.

I think you mean using regulator_get_linear_step

No, I don't. Why would that make sense? It limits the regulators that can be used and the properties of the regulator have no impact on what the SoC can support.

Quoted 7 lines
Quoted 4 lines

Or as I keep telling you guys the consumer can just do that directly using the existing API; the whole point in specifying the voltage as a range is to allow the consumer to cope with arbatrary regulators by giving a range of voltages that it can accept.

I agree. The intent of this series was to start a conversation to see if we can make it simpler.

It's already very simple. The consumer driver just needs to supply the list of voltages which it can accept, that's all.

Quoted 4 lines

For a generic driver which needs to handle platforms which have tolerance, they'd use regulator_set_voltage_tol. But the implementation would allow for uV - tol to uV + tol as range, which in the case I mentioned(min voltage =uV) wont work.

So just write it as an explicit voltage range then. For example many devices can tolerate any supply up to the maximum rated supply at any frequency so just specify that as the upper limit.

Quoted 3 lines

If the consumer wants to be aware of linear step regulator, they'd have to do:
step_uV = regulator_get_linear_step(...); regulator_set_voltage(uV, uV + step_uV);

Quoted 7 lines

No, the consumer really doesn't want to be aware of linear step regulators. Why would it care that there even are linear steps? If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem

The specific case that I am trying to tackle is as follows:
cpufreq-cpu0 uses definitions of voltages that are SoC specific. For a given frequency, the optimal voltage is X, max voltage(Y) is already expected to be in constraints for device functionality. We however want to find the closest voltage for a regulator in range X to Y best achievable by regulator. I think the area where I am getting confused is
this: I am thinking the job belongs to the consumer/regulator core to find the best match. However, looking at implementations in existing regulators and based on your explanation, it seems to be the job of the regulator driver rather than the consumer/ regulator core to provide the best match.

Thanks for the discussion and explanation.

Signature · 2 lines
Regards,
Nishanth Menon
maintainer
#6 lore raw
Quoted 10 lines · Nishanth Menon
Quoted 7 lines · Mark Brown

No, the consumer really doesn't want to be aware of linear step regulators. Why would it care that there even are linear steps? If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem If the consumer is doing this based on the properties of the regulator rather than on the properties of the consumer this indicates that the consumer has a problem

Quoted 11 lines

The specific case that I am trying to tackle is as follows:
cpufreq-cpu0 uses definitions of voltages that are SoC specific. For a given frequency, the optimal voltage is X, max voltage(Y) is already expected to be in constraints for device functionality. We however want to find the closest voltage for a regulator in range X to Y best achievable by regulator. I think the area where I am getting confused is
this: I am thinking the job belongs to the consumer/regulator core to find the best match. However, looking at implementations in existing regulators and based on your explanation, it seems to be the job of the regulator driver rather than the consumer/ regulator core to provide the best match.

Right, though the consumer does have to provide a voltage range to the regulator to allow this to happen - if the consumer doesn't provide a range then there's only one option available. The consumer provides a range and then the driver satistifes that as best it can (after it's been filtered through the constraints).