mx6: clock: Fix the calculation of PLL_ENET frequency
PATCH v2 1/1 mx6: clock: Fix the calculation of PLL_ENET frequency
From: Fabio Estevam <[email protected]>
According to the mx6 quad reference manual, the DIV_SELECT field of register CCM_ANALOG_PLL_ENETn has the following meaning:
"Controls the frequency of the ethernet reference clock.
- 00 - 25MHz
- 01 - 50MHz
- 10 - 100MHz
- 11 - 125MHz"
Current logic does not handle the 25MHz case correctly, so fix it.
---
Changes since v1:
- Use a single expression that correctly computes the frequency for all the DIV_SELECT combination (Troy Kisky)
arch/arm/cpu/armv7/mx6/clock.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
arch/arm/cpu/armv7/mx6/clock.c +1 -1
@@ -94,7 +94,7 @@ static u32 decode_pll(enum pll_clocks pll, u32 infreq) div =__raw_readl (&imx_ccm->analog_pll_enet); div &=BM_ANADIG_PLL_ENET_DIV_SELECT ; -return (div ==3 ?125000000 :25000000 * (div <<1 )); +return 25000000 * (div + (div >>1 ) +1 );default :return 0 ; }
Signature · 1 line
1.8.1.2
PATCH v2 1/1 mx6: clock: Fix the calculation of PLL_ENET frequency
Quoted 11 lines · Fabio Estevam
From: Fabio Estevam <[email protected]>
According to the mx6 quad reference manual, the
DIV_SELECTfield of registerCCM_ANALOG_PLL_ENETnhas the following meaning:"Controls the frequency of the ethernet reference clock.
- 00 - 25MHz
- 01 - 50MHz
- 10 - 100MHz
- 11 - 125MHz"
Quoted 5 lines
Current logic does not handle the 25MHz case correctly, so fix it.
Signed-off-by Rabeeh Khoury <[email protected]>Signed-off-by Fabio Estevam <[email protected]>---
Applied to u-boot-imx, thanks.
Best regards,
Stefano Babic
Signature · 5 lines
===================================================================== DENX Software Engineering GmbH, MD: Wolfgang Denk & Detlev Zundel HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic at denx.de =====================================================================