Skip to contentSkip to conversation

hwmon: (max1619) Fix critical alarm display

PATCH In review Guenter Roeck 1 participant 1 message Apr 19, 2014 Hardware monitoring

lore
Share & tools
lore

Guenter Roeck

author maintainer
#0 lore raw

PATCH 1/5 hwmon: (max1619) Fix critical alarm display

The overtemperature status bit, which is used to display critical alarm status, matches the output of the OVERT signal 1:1. If that signal is active-low, the bit will read 1 if there is no alarm. It is therefore necessary to reverse the bit in this case.

---
Candidate for -stable or not worth it ?

 drivers/hwmon/max1619.c |    5 +++++
 1 file changed, 5 insertions(+)
drivers/hwmon/max1619.c +5 -0
index 4c23afe..0927902 100644
@@ -325,6 +325,7 @@ static struct max1619_data *max1619_update_device(struct device *dev)
 {
 	struct i2c_client *client = to_i2c_client(dev);
 	struct max1619_data *data = i2c_get_clientdata(client);
+	int config;
 
 	mutex_lock(&data->update_lock);
 
@@ -344,6 +345,10 @@ static struct max1619_data *max1619_update_device(struct device *dev)
 					MAX1619_REG_R_TCRIT_HYST);
 		data->alarms = i2c_smbus_read_byte_data(client,
 					MAX1619_REG_R_STATUS);
+		/* If OVERT polarity is low, reverse alarm bit */
+		config = i2c_smbus_read_byte_data(client, MAX1619_REG_R_CONFIG);
+		if (!(config & 0x20))
+			data->alarms ^= 0x02;
 
 		data->last_updated = jiffies;
 		data->valid = 1;