hwmon: (max1619) Fix critical alarm display
Guenter Roeck
maintainerPATCH 1/5 hwmon: (max1619) Fix critical alarm display
The overtemperature status bit, which is used to display critical alarm status, matches the output of the OVERT signal 1:1. If that signal is active-low, the bit will read 1 if there is no alarm. It is therefore necessary to reverse the bit in this case.
Signed-off-by Guenter Roeck <[email protected]>
---
Candidate for -stable or not worth it ?
drivers/hwmon/max1619.c | 5 +++++ 1 file changed, 5 insertions(+)
drivers/hwmon/max1619.c +5 -0
@@ -325,6 +325,7 @@ static struct max1619_data *max1619_update_device(struct device *dev) {struct i2c_client *client =to_i2c_client (dev);struct max1619_data *data =i2c_get_clientdata (client); +int config;mutex_lock (&data->update_lock);
@@ -344,6 +345,10 @@ static struct max1619_data *max1619_update_device(struct device *dev) MAX1619_REG_R_TCRIT_HYST); data->alarms =i2c_smbus_read_byte_data (client,MAX1619_REG_R_STATUS ); +/* If OVERT polarity is low, reverse alarm bit */ + config =i2c_smbus_read_byte_data (client,MAX1619_REG_R_CONFIG ); +if (!(config &0x20 )) + data->alarms ^=0x02 ; data->last_updated = jiffies; data->valid =1 ;
Signature · 7 lines
1.7.9.7 _______________________________________________ lm-sensors mailing list [email protected] http://lists.lm-sensors.org/mailman/listinfo/lm-sensors