fencing: Replace syslog.syslog() calls with new logging handler
PATCH 1/1 fencing: Replace syslog.syslog() calls with new logging handler
Original logging handler for syslog writes everything to a device but that way we will have incorrect source. New logging handler is created on top of standard old-style syslog library.
--- fence/agents/lib/fencing.py.py | 36 ++++++++++++++++++++++++++++-------- 1 file changed, 28 insertions(+), 8 deletions(-)
fence/agents/lib/fencing.py.py +28 -8
@@ -414,7 +414,6 @@ def atexit_handler(): os.close(1) except IOError: logging.error("%s failed to close standard output\n", sys.argv[0]) - syslog.syslog(syslog.LOG_ERR, "Failed to close standard output") sys.exit(EC_GENERIC_ERROR) def add_dependency_options(options):
@@ -445,7 +444,6 @@ def fail(error_code): EC_INVALID_PRIVILEGES : "Failed: The user does not have the correct privileges to do the requested action." }[error_code] + "\n" logging.error("%s\n", message) - syslog.syslog(syslog.LOG_ERR, message) sys.exit(EC_GENERIC_ERROR) def usage(avail_opt):
@@ -618,7 +616,6 @@ def process_input(avail_opt): if avail_opt.count(name) == 0: logging.warning("Parse error: Ignoring unknown option '%s'\n", line) - syslog.syslog(syslog.LOG_WARNING, "Parse error: Ignoring unknown option '" + line) continue if all_opt[name]["getopt"].endswith(":"):
@@ -700,6 +697,12 @@ def check_input(device_opt, opt): if options.has_key("--verbose"): logging.getLogger().setLevel(logging.DEBUG) + ## add logging to syslog + logging.getLogger().addHandler(SyslogLibHandler()) + ## add loggint to stderr + logging.getLogger().addHandler(logging.StreamHandler(stream=sys.stderr)) + + acceptable_actions = ["on", "off", "status", "list", "monitor"] if 1 == device_opt.count("fabric_fencing"): ## Compatibility layer
@@ -920,13 +923,11 @@ def fence_action(tn, options, set_power_fn, get_power_fn, get_outlet_list=None, except Exception, ex: # an error occured during power ON phase in reboot # fence action was completed succesfully even in that case - logging.error("%s", str(ex)) - syslog.syslog(syslog.LOG_NOTICE, str(ex)) + logging.warning("%s", str(ex)) if power_on == False: # this should not fail as node was fenced succesfully logging.error('Timed out waiting to power ON\n') - syslog.syslog(syslog.LOG_NOTICE, "Timed out waiting to power ON") print "Success: Rebooted" elif options["--action"] == "status":
@@ -941,7 +942,6 @@ def fence_action(tn, options, set_power_fn, get_power_fn, get_outlet_list=None, fail(EC_TIMED_OUT) except pycurl.error, ex: logging.error("%s\n", str(ex)) - syslog.syslog(syslog.LOG_ERR, ex[1]) fail(EC_TIMED_OUT) return result
@@ -979,7 +979,6 @@ def fence_login(options, re_login_string=r"(login\s*: )|(Login Name: )|(usernam conn = fspawn(options, command) except pexpect.ExceptionPexpect, ex: logging.error("%s\n", str(ex)) - syslog.syslog(syslog.LOG_ERR, str(ex)) sys.exit(EC_GENERIC_ERROR) elif options.has_key("--ssh") and not options.has_key("--identity-file"): command = '%s %s %s@%s -p %s -o PubkeyAuthentication=no' % \
@@ -1135,3 +1134,24 @@ def fence_logout(conn, logout_string, sleep=0): # in format a.b.c.d...z and returned dict has key only z def array_to_dict(ar): return dict([[x[0].split(".")[-1], x[1]] for x in ar]) + + +## Own logger handler that uses old-style syslog handler as otherwise everything is sourced +## from /dev/syslog +class SyslogLibHandler(logging.StreamHandler): + """ + A handler class that correctly push messages into syslog + """ + def emit(self, record): + syslog_level = { + logging.CRITICAL:syslog.LOG_CRIT, + logging.ERROR:syslog.LOG_ERR, + logging.WARNING:syslog.LOG_WARNING, + logging.INFO:syslog.LOG_INFO, + logging.DEBUG:syslog.LOG_DEBUG, + logging.NOTSET:syslog.LOG_DEBUG, + }[record.levelno] + + msg = self.format(record) + syslog.syslog(syslog_level, msg) + return
Signature · 1 line
1.9.3