regulator: Ensure voltages are within the allowed range

PATCH In review Thierry Reding 2 participants 4 messages Nov 12, 2014 Voltage and current regulator framework

lore
Share & tools
lore
#0 lore raw

PATCH 1/1 regulator: Ensure voltages are within the allowed range

From: Thierry Reding <[email protected]>

Unless a regulator has a fixed output voltage the core will not attempt to modify the output voltage. This can cause a situation where a driver enables the regulator but the currently configured voltage is outside the valid range.

Fix this by constraining the current voltage to the allowed range upon regulator registration.

---
 drivers/regulator/core.c | 21 +++++++++++++++++++--
 1 file changed, 19 insertions(+), 2 deletions(-)
drivers/regulator/core.c +19 -2
index bbf93c9caca3..97851f39b4c0 100644
@@ -876,6 +876,7 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
 		int	max_uV = INT_MIN;
 		int	cmin = constraints->min_uV;
 		int	cmax = constraints->max_uV;
+		int	value;
 
 		/* it's safe to autoconfigure fixed-voltage supplies
 		   and the constraints are used by list_voltage. */
@@ -898,8 +899,6 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
 
 		/* initial: [cmin..cmax] valid, [min_uV..max_uV] not */
 		for (i = 0; i < count; i++) {
-			int	value;
-
 			value = ops->list_voltage(rdev, i);
 			if (value <= 0)
 				continue;
@@ -930,6 +929,24 @@ static int machine_constraints_voltage(struct regulator_dev *rdev,
 				 constraints->max_uV, max_uV);
 			constraints->max_uV = max_uV;
 		}
+
+		/*
+		 * Now that the voltage range has been determined, make sure
+		 * that the regulator's current voltage is within that range.
+		 */
+		value = _regulator_get_voltage(rdev);
+
+		if (value < constraints->min_uV ||
+		    value > constraints->max_uV) {
+			ret = _regulator_do_set_voltage(rdev,
+							constraints->min_uV,
+							constraints->max_uV);
+			if (ret < 0) {
+				rdev_err(rdev, "failed to set voltage to within %d-%d\n",
+					 constraints->min_uV, constraints->max_uV);
+				return ret;
+			}
+		}
 	}
 
 	return 0;
Signature · 1 line
2.1.3
maintainer
#1 lore raw
Quoted 9 lines · Thierry Reding

From: Thierry Reding <[email protected]>

Unless a regulator has a fixed output voltage the core will not attempt to modify the output voltage. This can cause a situation where a driver enables the regulator but the currently configured voltage is outside the valid range.

Fix this by constraining the current voltage to the allowed range upon regulator registration.

I've thought about doing this before but it's tricky as if there is a voltage range it's possible something needs it at the high rather than low end of the range and will get upset if the voltage gets lowered. Setting the top voltage also has risks (though less bad when constraints are sane) and requires working out what that is which we'd need to write the machinery to do.

This is all especially likely to break given the depressing desire everyone seems to have to put the maximum possible voltage range for their regulators in constraints regardless of what's actually sensible for their board design.

#2 lore raw
Quoted 18 lines · Mark Brown
Quoted 9 lines · Thierry Reding

From: Thierry Reding <[email protected]>

Unless a regulator has a fixed output voltage the core will not attempt to modify the output voltage. This can cause a situation where a driver enables the regulator but the currently configured voltage is outside the valid range.

Fix this by constraining the current voltage to the allowed range upon regulator registration.

I've thought about doing this before but it's tricky as if there is a voltage range it's possible something needs it at the high rather than low end of the range and will get upset if the voltage gets lowered. Setting the top voltage also has risks (though less bad when constraints are sane) and requires working out what that is which we'd need to write the machinery to do.

Quoted 4 lines

This is all especially likely to break given the depressing desire everyone seems to have to put the maximum possible voltage range for their regulators in constraints regardless of what's actually sensible for their board design.

Perhaps rather than checking that the voltage is within the valid range we could at least cover the case where voltage is zero, which is what triggered me to write this patch.

As it is, regulators with a valid voltage range but for which a voltage isn't explicitly set will remain off if their default voltage is 0.

Do you have any recommendations to work around this other than adjusting the actual voltage to be within the range?

Thierry

maintainer
#3 lore raw
Quoted 3 lines · Thierry Reding

Perhaps rather than checking that the voltage is within the valid range we could at least cover the case where voltage is zero, which is what triggered me to write this patch.

Anything which has a voltage of zero is buggy anyway, zero volts is the off state and should show up as such. If we don't have a voltage then the enable should fail.

Quoted 2 lines

Do you have any recommendations to work around this other than adjusting the actual voltage to be within the range?

Such regulators need a way of providing a bootsrapping voltage if they're off when we start I think.