clk/gk20a: fix max VCO value
PATCH 1/1 clk/gk20a: fix max VCO value
For some reason max_vco was set to a lower value that it can support, which prevented some clock states to be applied. Fix this by setting it to the same value as downstream.
Signed-off-by Alexandre Courbot <[email protected]>
--- nvkm/subdev/clock/gk20a.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
nvkm/subdev/clock/gk20a.c +1 -1
@@ -109,7 +109,7 @@ struct gk20a_clk_pllg_params { };static const struct gk20a_clk_pllg_params gk20a_pllg_params = { - .min_vco =1000 , .max_vco =1700 , + .min_vco =1000 , .max_vco =2064 , .min_u =12 , .max_u =38 , .min_m =1 , .max_m =255 , .min_n =8 , .max_n =255 ,
Signature · 6 lines
2.1.3 _______________________________________________ Nouveau mailing list [email protected] http://lists.freedesktop.org/mailman/listinfo/nouveau