Fix: Live tracing does not honor live timer after first tracefile with tracefile rotation
A message that is not in the archive (sent off-list or not yet received): [email protected]
Merged all the way to 2.4, thanks!
Jérémie
Quoted 33 lines · Mathieu Desnoyers
When we pass to the 2nd sub-file (or following sub-files) of a stream in relayd, the live timer has no visible effect from a live reader perspective, and then everything is flushed when we reach the following sub-file.
This is caused by the reset of
stream->total_index_receivedafter each tracefile rotation. It should keep on incrementing to match what is expected by check incheck_index_status():(
rstream->total_index_received<=vstream->last_sent_index)Fixes #863
Signed-off-by Mathieu Desnoyers <[email protected]>--- src/bin/lttng-relayd/main.c | 1 - 1 file changed, 1 deletion(-)src/bin/lttng-relayd/main.c +0
-2@@ -2333,7 +2333,6 @@ int relay_process_data(struct relay_connection *conn) stream->tracefile_size, stream->tracefile_count, relayd_uid, relayd_gid, stream->fd, &(stream->tracefile_count_current), &stream->fd); - stream->total_index_received =0 ;pthread_mutex_unlock (&stream->viewer_stream_rotation_lock);if (ret <0 ) {ERR ("Rotating stream output file" ); --2.1.1
Signature · 8 lines
Jérémie Galarneau EfficiOS Inc. http://www.efficios.com _______________________________________________ lttng-dev mailing list [email protected] http://lists.lttng.org/cgi-bin/mailman/listinfo/lttng-dev