Skip to contentSkip to conversation

armada thermal issues with negative temperatures

PATCH Damien Thébault 1 participant 1 message May 23, 2016

Subsystems (2)
lore
Share & tools
lore
#0 lore raw

Hello,

I've been using an armada 370 SoC, and the thermal driver is reporting erroneous values at negative temperatures.

After looking at what happened, in the armada_get_temp() function, after applying shift and mask, we get the following values around 0?C:
- 315 (just above 0)
- 316 (just below 0)

If the code after /* Get formula coeficients */ is executed with those two values, the first one gives the proper value of 216, but the second one gives 310160 instead of the proper value of -506.

To have the proper final value, a signed division must be performed, which will only be done if both operands are signed according to the C standard, otherwise an unsigned division is done, which will provide wrong results.

As the current coefficients are just fitting in unsigned long values, the best fix I could find was to just cast each operand to (signed) long.

With this fix, the temperature is the proper one, even for negative values.

Best Regards
---
?drivers/thermal/armada_thermal.c | 4 ++--
?1 file changed, 2 insertions(+), 2 deletions(-)

(quoted diff) +0 -0

b/drivers/thermal/armada_thermal.c
index ae75328..ad8b88c 100644

drivers/thermal/armada_thermal.c +0 -0
@@ -177,9 +177,9 @@ static int armada_get_temp(struct

thermal_zone_device *thermal,
? div = priv->data->coef_div;
?
? if (priv->data->inverted)
- *temp = ((m * reg) - b) / div;
+ *temp = (long)((m * reg) - b) / (long)div;
? else
- *temp = (b - (m * reg)) / div;
+ *temp = (long)(b - (m * reg)) / (long)div;
? return 0;
?}
?
--?
2.8.2

Signature · 1 line
Damien Th?bault