nvmet: Add support for HOST_ID feature.
Subsystems (2)
PATCH v4 1/1 nvmet: Add support for HOST_ID feature.
Add host_id feature to NVMeoF targets. This will be required in order to support reservations.
Signed-off-by: Omri Mann <omri at excelero.com>
--- drivers/nvme/target/admin-cmd.c | 14 ++++++++++++-- drivers/nvme/target/fabrics-cmd.c | 1 + drivers/nvme/target/nvmet.h | 2 ++ 3 files changed, 15 insertions(+), 2 deletions(-)
drivers/nvme/target/admin-cmd.c +12 -2
@@ -387,7 +387,7 @@ static void nvmet_execute_set_features(struct nvmet_req *req)u32 val32;u16 status =0 ; -switch (cdw10 &0xf ) { +switch (cdw10 &0xff ) {case NVME_FEAT_NUM_QUEUES :nvmet_set_result (req, (subsys->max_qid -1 ) | ((subsys->max_qid -1 ) <<16 ));
@@ -397,6 +397,9 @@ static void nvmet_execute_set_features(struct nvmet_req *req) req->sq->ctrl->kato =DIV_ROUND_UP (val32,1000 );nvmet_set_result (req, req->sq->ctrl->kato);break ; +case NVME_FEAT_HOST_ID : + status =NVME_SC_CMD_SEQ_ERROR |NVME_SC_DNR ; +break ;default : status =NVME_SC_INVALID_FIELD |NVME_SC_DNR ;break ;
@@ -411,7 +414,7 @@ static void nvmet_execute_get_features(struct nvmet_req *req)u32 cdw10 =le32_to_cpu (req->cmd->common.cdw10[0 ]);u16 status =0 ; -switch (cdw10 &0xf ) { +switch (cdw10 &0xff ) {/* * These features are mandatory in the spec, but we don't * have a useful way to implement them. We'll eventually
@@ -445,6 +448,13 @@ static void nvmet_execute_get_features(struct nvmet_req *req)case NVME_FEAT_KATO :nvmet_set_result (req, req->sq->ctrl->kato *1000 );break ; +case NVME_FEAT_HOST_ID : +if (!(le32_to_cpu (req->cmd->common.cdw10[1 ]) &1 )) + status =NVME_SC_INVALID_FIELD |NVME_SC_DNR ; +else + status =nvmet_copy_to_sgl (req,0 , + req->sq->ctrl->hostid,sizeof (req->sq->ctrl->hostid)); +break ;default : status =NVME_SC_INVALID_FIELD |NVME_SC_DNR ;break ;
drivers/nvme/target/fabrics-cmd.c +1 -0
@@ -154,6 +154,7 @@ static void nvmet_execute_admin_connect(struct nvmet_req *req) le32_to_cpu(c->kato), &ctrl);if (status) goto out; +memcpy (ctrl->hostid, d->hostid,sizeof (ctrl->hostid)); status =nvmet_install_queue (ctrl, req);if (status) {
drivers/nvme/target/nvmet.h +2 -0
@@ -108,6 +108,8 @@ struct nvmet_ctrl {struct nvmet_cq **cqs;struct nvmet_sq **sqs; +u8 hostid[16 ]; +struct mutex lock;u64 cap;u64 serial;
Signature · 1 line
1.8.3.1
PATCH v4 1/1 nvmet: Add support for HOST_ID feature.
Review
Quoted 2 lines
(quoted diff) +1
-1- switch (cdw10 & 0xf) { + switch (cdw10 & 0xff) {
This is a new change compared to the previous one. It looks correct to me as we need the bigger mask, but it should have been documented in the changelog. I'll fix it up and apply the patch.