pwm: tegra: dynamic clk freq configuration by PWM driver
Subsystems (3)
PATCH 1/1 pwm: tegra: dynamic clk freq configuration by PWM driver
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock source.
Changes mainly have 2 parts:
- T186 and later chips [1]
- T210 and prior chips [2]
For [1] - Changes implemented to set pwm period dynamically and
also checks added to allow only if requested period(ns) is below or equals to higher range.
For [2] - Only checks if the requested period(ns) is below or equals
to higher range defined by max clock limit. The limitation in T210 or prior chips are due to the reason of having only one pwm-controller supporting multiple channels. But later chips have multiple pwm controller instances each having single channel support.
--- drivers/pwm/pwm-tegra.c | 45 +++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 43 insertions(+), 2 deletions(-)
drivers/pwm/pwm-tegra.c +43 -2
@@ -4,7 +4,7 @@* * Tegra pulse-width-modulation controller driver * -* Copyright (c) 2010, NVIDIA Corporation. +* Copyright (c) 2010-2020, NVIDIA Corporation. * Based on arch/arm/plat-mxc/pwm.c by Sascha Hauer <[email protected]> */
@@ -83,10 +83,51 @@ static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, val = (u32 )c <<PWM_DUTY_SHIFT ;/* +* Its okay to ignore the fraction part since we will be trying to set +* slightly lower value to rate than the actual required rate +*/ + rate =NSEC_PER_SEC /period_ns; + +/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ; + +/* * Compute the prescaler value for which (1 << PWM_DUTY_WIDTH) * cycles at the PWM clock rate will take period_ns nanoseconds. */ - rate = pc->clk_rate >>PWM_DUTY_WIDTH ; +if (pc->soc->num_channels ==1 ) { +/* +* Rate is multiplied with 2^PWM_DUTY_WIDTH so that it matches +* with the hieghest applicable rate that the controller can +* provide. Any further lower value can be derived by setting +* PFM bits[0:12]. +* Higher mark is taken since BPMP has round-up mechanism +* implemented. +*/ + rate = rate <<PWM_DUTY_WIDTH ; + + err =clk_set_rate (pc->clk, rate); +if (err <0 ) +return -EINVAL ; + + rate =clk_get_rate (pc->clk) >>PWM_DUTY_WIDTH ; + }else { +/* +* This is the case for SoCs who support multiple channels: +* +* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe. +*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz =DIV_ROUND_CLOSEST_ULL (100ULL *NSEC_PER_SEC , period_ns);
Signature · 1 line
2.7.4
Quoted 6 lines · Sandipan Patra
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock source.
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?
And slightly orthogonal to this patch: The tegra driver needs some love to make it use the atomic callback .apply() instead of .config()/.enable()/.disable() and a .get_state() implementation.
Quoted 34 lines
Changes mainly have 2 parts:
- T186 and later chips [1]
- T210 and prior chips [2]For [1] - Changes implemented to set pwm period dynamically and
also checks added to allow only if requested period(ns) is below or equals to higher range.For [2] - Only checks if the requested period(ns) is below or equals
to higher range defined by max clock limit. The limitation in T210 or prior chips are due to the reason of having only one pwm-controller supporting multiple channels. But later chips have multiple pwm controller instances each having single channel support.Signed-off-by Sandipan Patra <[email protected]>--- drivers/pwm/pwm-tegra.c | 45 +++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 43 insertions(+), 2 deletions(-)drivers/pwm/pwm-tegra.c +1
-1@@ -4,7 +4,7 @@* * Tegra pulse-width-modulation controller driver * -* Copyright (c) 2010, NVIDIA Corporation. +* Copyright (c) 2010-2020, NVIDIA Corporation. * Based on arch/arm/plat-mxc/pwm.c by Sascha Hauer <[email protected]> */
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 87
Quoted 5 lines
drivers/pwm/pwm-tegra.c +2
-0@@ -83,10 +83,51 @@ static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, val = (u32 )c <<PWM_DUTY_SHIFT ;/* +* Its okay to ignore the fraction part since we will be trying to set +* slightly lower value to rate than the actual required rate
s/actual/actually/
You round down the rate, that results in rounding up period and duty_cycle, right? If so, that's wrong. (Note that if the driver would use the atomic callbacks, the just introduced debug checks would tell you this.)
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 89
Quoted 2 lines
drivers/pwm/pwm-tegra.c +2
-0+*/ + rate =NSEC_PER_SEC /period_ns;
space around / please.
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 98
Quoted 9 lines
drivers/pwm/pwm-tegra.c +9
-0+ +/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;
Related to my question above: What happens if the rate increases after this check?
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
NSEC_PER_SEC / period_ns > (max_frequency >> PWM_DUTY_WIDTH)
This is equivalent to
period_ns <= NSEC_PER_SEC / (max_frequency >> PWM_DUTY_WIDTH)
where the right side is constant per PWM type. (Rounding might need addressing.)
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 107
Quoted 10 lines
drivers/pwm/pwm-tegra.c +6
-1+ +/* * Compute the prescaler value for which (1 << PWM_DUTY_WIDTH) * cycles at the PWM clock rate will take period_ns nanoseconds. */ - rate = pc->clk_rate >>PWM_DUTY_WIDTH ; +if (pc->soc->num_channels ==1 ) { +/* +* Rate is multiplied with 2^PWM_DUTY_WIDTH so that it matches +* with the hieghest applicable rate that the controller can
typo: s/hieghest/highest/
Quoted 5 lines
drivers/pwm/pwm-tegra.c +5
-0+* provide. Any further lower value can be derived by setting +* PFM bits[0:12]. +* Higher mark is taken since BPMP has round-up mechanism +* implemented. +*/
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 122
Quoted 10 lines
drivers/pwm/pwm-tegra.c +10
-0+ rate = rate <<PWM_DUTY_WIDTH ; + + err =clk_set_rate (pc->clk, rate); +if (err <0 ) +return -EINVAL ; + + rate =clk_get_rate (pc->clk) >>PWM_DUTY_WIDTH ; + }else { +/* +* This is the case for SoCs who support multiple channels:
s/who/that/
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 127
Quoted 5 lines
drivers/pwm/pwm-tegra.c +5
-0+* +* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe.
I don't understand that. If
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 133
Quoted 6 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz =DIV_ROUND_CLOSEST_ULL (100ULL *NSEC_PER_SEC , period_ns);
I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8-bit DUTY value. There is an internal counter incrementing by one each (SCALE + 1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.
So we have:
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
There are a few things that could be improved in the driver:
- .config() does quite some divisions. This could be reduced which probably even reduces rounding effects.
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the currently running period?
Best regards
Uwe
Signature · 2 lines
Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | https://www.pengutronix.de/ |
Thank you Uwe for reviewing the changes.
And sorry for the delay in my response.
Please find the responses inline.
Thanks & Regards,
Sandipan
Quoted 22 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Friday, April 3, 2020 8:41 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Quoted 6 lines · Sandipan Patra
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock source.
Quoted 4 lines
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?
Yes, frequency can be changed anytime but by the same process who has acquired the channel. So if a process is already running/using the channel, same process can only modify the frequency.
Quoted 4 lines
And slightly orthogonal to this patch: The tegra driver needs some love to make it use the atomic callback .apply() instead of .config()/.enable()/.disable() and a .get_state() implementation.
Understood to upgrade pwm-tegra driver with using .apply() I will work on this with a new change request soon.
Quoted 38 lines
Quoted 27 lines
Changes mainly have 2 parts:
- T186 and later chips [1]
- T210 and prior chips [2]For [1] - Changes implemented to set pwm period dynamically and
also checks added to allow only if requested period(ns) is below or equals to higher range.For [2] - Only checks if the requested period(ns) is below or equals
to higher range defined by max clock limit. The limitation in T210 or prior chips are due to the reason of having only one pwm-controller supporting multiple channels. But later chips have multiple pwm controller instances each having
single channel support.Signed-off-by Sandipan Patra <[email protected]>--- drivers/pwm/pwm-tegra.c | 45 +++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 43 insertions(+), 2 deletions(-)drivers/pwm/pwm-tegra.c index renamed from drivers/pwm/pwm-tegra.c +0
-0aa12fb3..d3ba33c 100644
drivers/pwm/pwm-tegra.c line 8
Quoted 6 lines
drivers/pwm/pwm-tegra.c +1
-1@@ -4,7 +4,7 @@* * Tegra pulse-width-modulation controller driver * -* Copyright (c) 2010, NVIDIA Corporation. +* Copyright (c) 2010-2020, NVIDIA Corporation. * Based on arch/arm/plat-mxc/pwm.c by Sascha Hauer drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip,
Quoted 3 lines
drivers/pwm/pwm-tegra.c +0
-0*/ @@ -83,10 +83,51 @@ static int tegra_pwm_config(struct pwm_chip *chip,struct
pwm_device*pwm,
Quoted 7 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 87
Quoted 5 lines
drivers/pwm/pwm-tegra.c +2
-0val = (u32 )c <<PWM_DUTY_SHIFT ;/* +* Its okay to ignore the fraction part since we will be trying to set +* slightly lower value to rate than the actual required rate s/actual/actually/
Noted. I will update in the follow up patch.
Quoted 9 lines
You round down the rate, that results in rounding up period and
duty_cycle, right? If so, that's wrong. (Note that if the driver would use the atomic callbacks, the just introduced debug checks would tell you this.)drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 89
Quoted 2 lines
drivers/pwm/pwm-tegra.c +2
-0+*/ + rate =NSEC_PER_SEC /period_ns;space around / please.
Noted. I will update in the follow up patch.
Quoted 11 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 98
Quoted 10 lines
drivers/pwm/pwm-tegra.c +9
-0+ +/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;
Quoted 2 lines
Related to my question above: What happens if the rate increases after this check?
Discussed above with my understanding. Please help me understand if you are referring to any other possibilities that rate can be changed.
Quoted 6 lines
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
Quoted 8 lines
NSEC_PER_SEC/period_ns> (max_frequency>>PWM_DUTY_WIDTH)This is equivalent to
period_ns<=NSEC_PER_SEC/ (max_frequency>>PWM_DUTY_WIDTH)where the right side is constant per PWM type. (Rounding might need addressing.)
I will update this calculation in the probe since max_frequency value is Different for each chip. Also please note that at this point the rate is not the actual pwm output rate. It's just a reference for what should be the source clock rate and then requested with clk_set_rate();
Actual rounding is required while setting pwm controller output rate is done later down in same function.
Quoted 13 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm,
Quoted 12 lines
drivers/pwm/pwm-tegra.c +7
-1+ +/* * Compute the prescaler value for which (1 << PWM_DUTY_WIDTH) * cycles at the PWM clock rate will take period_ns nanoseconds. */ - rate = pc->clk_rate >>PWM_DUTY_WIDTH ; +if (pc->soc->num_channels ==1 ) { +/* +* Rate is multiplied with 2^PWM_DUTY_WIDTH so that it matches +* with the hieghest applicable rate that the controller +can
Quoted 1 line
typo: s/hieghest/highest/
Noted. I will update in the follow up patch.
Quoted 10 lines
Quoted 10 lines
drivers/pwm/pwm-tegra.c +9
-0+* provide. Any further lower value can be derived by setting +* PFM bits[0:12]. +* Higher mark is taken since BPMP has round-up mechanism +* implemented. +*/ + rate = rate <<PWM_DUTY_WIDTH ; + + err =clk_set_rate (pc->clk, rate); +if (err <0 )
Quoted 8 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 122
Quoted 6 lines
drivers/pwm/pwm-tegra.c +6
-0+return -EINVAL ; + + rate =clk_get_rate (pc->clk) >>PWM_DUTY_WIDTH ; + }else { +/* +* This is the case for SoCs who support multiple channels: s/who/that/
Noted. I will update in the follow up patch.
Quoted 8 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 127
Quoted 6 lines
drivers/pwm/pwm-tegra.c +5
-0+* +* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe. I don't understand that. If
The if part is for SoCs which have single channel per pwm instance. i.e. T186, T194 etc. For controllers with single channel, dynamic clock rate configuration is possible. The other part is for legacy controller which has multiple channels for single pwm instance. The pwm controllers having multiple channels share the source clock. So it does not allow dynamic clock configuration since it will affect users on the other channels.
Quoted 16 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 133
Quoted 6 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz =DIV_ROUND_CLOSEST_ULL (100ULL *NSEC_PER_SEC , period_ns);I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8- bit DUTY value. There is an internal counter incrementing by one each (SCALE +
1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.
Quoted 6 lines
So we have:
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
Yes. Right.
Quoted 5 lines
There are a few things that could be improved in the driver:
- .config() does quite some divisions. This could be reduced which probably even reduces rounding effects.
Explained above and will move the calculation to probe.
Quoted 3 lines
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
Yes, PWM controller is capable to provide 100% duty cycle. Bits 30:16 are dedicated for pulse width out of which only 24:16 (9 bits) are used. Only 8 bits are usable [23:16] for varying pulse width. To achieve 100% duty cycle, Bit [24] needs to be programmed of this register to 1'b1.
Quoted 6 lines
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
Yes, you are right. The comment needs a correction. It will be plus 1 instead of minus 1. I will update the comment in the follow up patch. Otherwise the calculation is correct.
rate = DIV_ROUND_CLOSEST_ULL(100ULL * rate, hz);
here rate is the divider value to be set.
Quoted 5 lines
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the currently running period?
Yes, it allows to write the bit during any active and inactive time of the width. Hence the pwm gets disabled as soon as the enable bit is set to 0.
Quoted 7 lines
Best regards
Uwe--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |
Hello,
Quoted 2 lines · Sandipan Patra
Thank you Uwe for reviewing the changes.
And sorry for the delay in my response.
No problem, I didn't held my breath :-)
Quoted 22 lines
Quoted 22 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Friday, April 3, 2020 8:41 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Quoted 6 lines · Sandipan Patra
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock source.
Quoted 8 lines
Quoted 4 lines
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?Yes, frequency can be changed anytime but by the same process who has acquired the channel. So if a process is already running/using the channel, same process can only modify the frequency.
How is this enforced? Does some other peripheral get its input clock from the clock in question? What is the motivation to modify the frequency other than modifying the PWM output?
Quoted 6 lines
Quoted 3 lines
And slightly orthogonal to this patch: The tegra driver needs some love to make it use the atomic callback .apply() instead of .config()/.enable()/.disable() and a .get_state() implementation.
Understood to upgrade pwm-tegra driver with using .apply() I will work on this with a new change request soon.
That's great (but still not holding my breath :-)
Quoted 37 lines
Quoted 37 lines
Quoted 37 lines
Changes mainly have 2 parts:
- T186 and later chips [1]
- T210 and prior chips [2]For [1] - Changes implemented to set pwm period dynamically and
also checks added to allow only if requested period(ns) is below or equals to higher range.For [2] - Only checks if the requested period(ns) is below or equals
to higher range defined by max clock limit. The limitation in T210 or prior chips are due to the reason of having only one pwm-controller supporting multiple channels. But later chips have multiple pwm controller instances each having
single channel support.Signed-off-by Sandipan Patra <[email protected]>--- drivers/pwm/pwm-tegra.c | 45 +++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 43 insertions(+), 2 deletions(-)drivers/pwm/pwm-tegra.c index renamed from drivers/pwm/pwm-tegra.c +0
-0aa12fb3..d3ba33c 100644
drivers/pwm/pwm-tegra.c +1
-1@@ -4,7 +4,7 @@* * Tegra pulse-width-modulation controller driver * -* Copyright (c) 2010, NVIDIA Corporation. +* Copyright (c) 2010-2020, NVIDIA Corporation. * Based on arch/arm/plat-mxc/pwm.c by Sascha Hauer <[email protected]> */ @@ -83,10 +83,51 @@ static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, val = (u32 )c <<PWM_DUTY_SHIFT ;
Quoted 7 lines
Quoted 5 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 87
Quoted 3 lines
drivers/pwm/pwm-tegra.c +2
-0/* +* Its okay to ignore the fraction part since we will be trying to set +* slightly lower value to rate than the actual required rate s/actual/actually/
Noted. I will update in the follow up patch.
Just spotted: s/Its/It's/
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
drivers/pwm/pwm-tegra.c +8
-0+/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;
Quoted 5 lines
Quoted 2 lines
Related to my question above: What happens if the rate increases after this check?
Discussed above with my understanding. Please help me understand if you are referring to any other possibilities that rate can be changed.
The goal to reach is: The only way to modify the PWM output should be to call pwm_apply_state() (or its legacy relatives).
Quoted 14 lines
Quoted 5 lines
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
Quoted 8 lines
NSEC_PER_SEC/period_ns> (max_frequency>>PWM_DUTY_WIDTH)This is equivalent to
period_ns<=NSEC_PER_SEC/ (max_frequency>>PWM_DUTY_WIDTH)where the right side is constant per PWM type. (Rounding might need addressing.)
Quoted 6 lines
I will update this calculation in the probe since
max_frequencyvalue is Different for each chip. Also please note that at this point the rate is not the actual pwm output rate. It's just a reference for what should be the source clock rate and then requested withclk_set_rate();
Actual rounding is required while setting pwm controller output rate is done later down in same function.
I think I understood. Will check again in your next patch round.
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines
drivers/pwm/pwm-tegra.c +4
-0+* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe.
Quoted 8 lines
Quoted 1 line
I don't understand that. If
The if part is for SoCs which have single channel per pwm instance. i.e. T186, T194 etc. For controllers with single channel, dynamic clock rate configuration is possible. The other part is for legacy controller which has multiple channels for single pwm instance. The pwm controllers having multiple channels share the source clock. So it does not allow dynamic clock configuration since it will affect users on the other channels.
The usual approach here is to allow changes iff all other channels are off or unused.
Quoted 16 lines
Quoted 16 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 133
Quoted 6 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz =DIV_ROUND_CLOSEST_ULL (100ULL *NSEC_PER_SEC , period_ns);I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8- bit DUTY value. There is an internal counter incrementing by one each (SCALE +
1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.
Quoted 8 lines
Quoted 6 lines
So we have:
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
Yes. Right.
Ideally this would be described in a code comment.
Quoted 8 lines
Quoted 2 lines
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
Yes, PWM controller is capable to provide 100% duty cycle. Bits 30:16 are dedicated for pulse width out of which only 24:16 (9 bits) are used. Only 8 bits are usable [23:16] for varying pulse width. To achieve 100% duty cycle, Bit [24] needs to be programmed of this register to 1'b1.
This needs to be documented in a driver comment to be understandable for people being interested in this driver later.
If Bit[24] is 1, should [23:16] be zero, or is it "don't care" then?
Quoted 11 lines
Quoted 5 lines
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
Yes, you are right. The comment needs a correction. It will be plus 1 instead of minus 1. I will update the comment in the follow up patch. Otherwise the calculation is correct.
rate =DIV_ROUND_CLOSEST_ULL(100ULL * rate, hz);
here rate is the divider value to be set.
If a certain duty+period is requested the driver is supposed to provide an output such that:
implemented_period = max{ possible periods <= requested period }
implemented_duty = max{ possible duty <= requested duty }so I think DIV_ROUND_CLOSEST_ULL is wrong.
(If the driver provided the modern callback instead of .config/.enable/.disable CONFIG_PWM_DEBUG would help you here.)
Quoted 7 lines
Quoted 4 lines
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the currently running period?
Yes, it allows to write the bit during any active and inactive time of the width. Hence the pwm gets disabled as soon as the enable bit is set to 0.
OK, so the output stops oscillating as soon as the PWM_ENABLE bit is cleared in hardware. How does the output behave then? (Does the output become inactive? Or does it drive the output level where it just happens to be?) I assume that the register write in tegra_pwm_config() also results in aborting the currently running period and start of a new one with the new settings?
Best regards
Uwe
Signature · 2 lines
Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | https://www.pengutronix.de/ |
Quoted 52 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Wednesday, April 15, 2020 7:49 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Hello,
Quoted 2 lines · Sandipan Patra
Thank you Uwe for reviewing the changes.
And sorry for the delay in my response.No problem, I didn't held my breath :-)
Quoted 15 lines
Quoted 15 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Friday, April 3, 2020 8:41 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Quoted 7 lines
Quoted 7 lines · Sandipan Patra
Quoted 6 lines
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock
source.
Quoted 6 lines
Quoted 5 lines
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?
Quoted 7 lines
Quoted 3 lines
Yes, frequency can be changed anytime but by the same process who has acquired the channel. So if a process is already running/using the channel, same process can only modify the frequency.
How is this enforced? Does some other peripheral get its input clock from the clock in question? What is the motivation to modify the frequency other than modifying the PWM output?
PWM instance uses a derived clock and sets the divider for further division of rate. Regarding modifying frequency: it was my wrong interpretation. I mean, to modify the PWM output the driver first sets the clock rate which allows to configure the requested PWM output.
Quoted 54 lines
Quoted 7 lines
Quoted 4 lines
And slightly orthogonal to this patch: The tegra driver needs some love to make it use the atomic callback .apply() instead of .config()/.enable()/.disable() and a .get_state() implementation.
Understood to upgrade pwm-tegra driver with using .apply() I will work on this with a new change request soon.
That's great (but still not holding my breath :-)
Quoted 21 lines
Quoted 21 lines
Quoted 21 lines
Changes mainly have 2 parts:
- T186 and later chips [1]
- T210 and prior chips [2]For [1] - Changes implemented to set pwm period dynamically and
also checks added to allow only if requested period(ns) is below or equals to higher range.For [2] - Only checks if the requested period(ns) is below or equals
to higher range defined by max clock limit. The limitation in T210 or prior chips are due to the reason of having only one pwm-controller supporting multiple channels. But later chips have multiple pwm controller instances each having
single channel support.Signed-off-by Sandipan Patra <[email protected]>--- drivers/pwm/pwm-tegra.c | 45 +++++++++++++++++++++++++++++++++++++++++++-- 1 file changed, 43 insertions(+), 2 deletions(-)Quoted 11 lines
Quoted 11 lines
drivers/pwm/pwm-tegra.c line 8
Quoted 11 lines
drivers/pwm/pwm-tegra.c +1
-1@@ -4,7 +4,7 @@* * Tegra pulse-width-modulation controller driver * -* Copyright (c) 2010, NVIDIA Corporation. +* Copyright (c) 2010-2020, NVIDIA Corporation. * Based on arch/arm/plat-mxc/pwm.c by Sascha Hauer Quoted 3 lines
Quoted 3 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip
Quoted 3 lines
drivers/pwm/pwm-tegra.c +0
-0*/ @@ -83,10 +83,51 @@ static int tegra_pwm_config(struct pwm_chip*chip, struct
pwm_device*pwm,Quoted 7 lines
Quoted 7 lines
Quoted 6 lines
drivers/pwm/pwm-tegra.c +3
-0val = (u32 )c <<PWM_DUTY_SHIFT ;/* +* Its okay to ignore the fraction part since we will be trying to set +* slightly lower value to rate than the actual required +rate
Quoted 6 lines
Quoted 3 lines
Quoted 1 line
s/actual/actually/
Noted. I will update in the follow up patch.
Just spotted: s/Its/It's/
This comment section is going to be removed on next patch as the calculation it points is going to be inside probe as per earlier discussion.
Quoted 9 lines
Quoted 9 lines
Quoted 9 lines
Quoted 8 lines
drivers/pwm/pwm-tegra.c +8
-0+/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;
Quoted 8 lines
Quoted 5 lines
Quoted 2 lines
Related to my question above: What happens if the rate increases after this check?
Discussed above with my understanding. Please help me understand if you are referring to any other possibilities that rate can be changed.
The goal to reach is: The only way to modify the PWM output should be to call
pwm_apply_state()(or its legacy relatives).
I see with current settings, pwm output gets modified by .config() which comes from pwm_apply_state(). I think it suffices the purpose or I am still missing anything?
Quoted 39 lines
Quoted 16 lines
Quoted 8 lines
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
NSEC_PER_SEC/period_ns> (max_frequency>>PWM_DUTY_WIDTH)Quoted 7 lines
This is equivalent to
period_ns<=NSEC_PER_SEC/ (max_frequency>>PWM_DUTY_WIDTH)where the right side is constant per PWM type. (Rounding might need addressing.)
Quoted 6 lines
I will update this calculation in the probe since
max_frequencyvalue is Different for each chip. Also please note that at this point the rate is not the actual pwm output rate. It's just a reference for what should be the source clock rate and then requested withclk_set_rate(); Actual rounding is required while setting pwm controller output rate is done later down in same function.I think I understood. Will check again in your next patch round.
Quoted 7 lines
Quoted 6 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 127
Quoted 4 lines
drivers/pwm/pwm-tegra.c +4
-0+* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe. I don't understand that. If
Quoted 7 lines
The if part is for SoCs which have single channel per pwm instance. i.e. T186,
T194 etc. For controllers with single channel, dynamic clock rate configuration is possible. The other part is for legacy controller which has multiple channels for single pwm instance. The pwm controllers having multiple channels share the source clock. So it does not allow dynamic clock configuration since it will affect users on the
Quoted 5 lines
other channels.
The usual approach here is to allow changes iff all other channels are off or unused.
This is handled in the if part, where pwm instances have only one channel and only the dynamic clock configuration can be done. On the other side (under else part), the rate is stored during probe and it does not get modified during run time.
Quoted 20 lines
Quoted 20 lines
Quoted 20 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm,
Quoted 7 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz =DIV_ROUND_CLOSEST_ULL (100ULL *NSEC_PER_SEC , period_ns);I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8- bit DUTY value. There is an internal counter incrementing by one each (SCALE +
1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.So we have:
Quoted 8 lines
Quoted 6 lines
Quoted 4 lines
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
Yes. Right.
Ideally this would be described in a code comment.
Ok.
I will add adequate comments to help providing the register insights.
Quoted 4 lines
Quoted 4 lines
Quoted 3 lines
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
Quoted 9 lines
Quoted 5 lines
Yes, PWM controller is capable to provide 100% duty cycle. Bits 30:16 are dedicated for pulse width out of which only 24:16 (9 bits) are used. Only 8 bits are usable [23:16] for varying pulse width. To achieve 100% duty cycle, Bit [24] needs to be programmed of this register to 1'b1.
This needs to be documented in a driver comment to be understandable for people being interested in this driver later.
Sure. As stated above, I will add the details in code comment. And for further Understanding Tegra documents and specifications can be followed.
Quoted 2 lines
If Bit[24] is 1, should [23:16] be zero, or is it "don't care" then?
Once the 24th bit is set, all other bits are considered to be don't care.
Quoted 12 lines
Quoted 11 lines
Quoted 5 lines
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
Yes, you are right. The comment needs a correction. It will be plus 1 instead of minus 1. I will update the comment in the follow up patch. Otherwise the calculation is correct.
rate =DIV_ROUND_CLOSEST_ULL(100ULL * rate, hz); here rate is the divider value to be set.
Quoted 6 lines
If a certain duty+period is requested the driver is supposed to provide an output such that:
implemented_period = max{ possible periods <= requested period } implemented_duty = max{ possible duty <= requested duty }
I am not clear if I understood the question correctly. implemented_period = max{ possible periods <= requested period } should it be, min { possible periods, requested period } ?
If you are asking for requested parameters to fall inside range, this is taken care at below checks.
if (period_ns < min_period_ns) //lower bound
And if (rate >> PWM_SCALE_WIDTH) //higher bound
If I am not clear with the question, please help me understanding.
Quoted 3 lines
so I think
DIV_ROUND_CLOSEST_ULLis wrong.
(If the driver provided the modern callback instead of .config/.enable/.disableCONFIG_PWM_DEBUGwould help you here.)
FYI, I will further be working on a separate change sets for tegra pwm driver to use atomic callbacks.
Quoted 6 lines
Quoted 6 lines
Quoted 5 lines
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the currently running period?
Quoted 8 lines
Quoted 2 lines
Yes, it allows to write the bit during any active and inactive time of the width. Hence the pwm gets disabled as soon as the enable bit is set to 0.
OK, so the output stops oscillating as soon as the
PWM_ENABLEbit is cleared in hardware. How does the output behave then? (Does the output become inactive? Or does it drive the output level where it just happens to be?) I assume that the register write integra_pwm_config()also results in aborting the currently running period and start of a new one with the new settings?
Yes, the output stops as soon as the PWM_ENABLE bit is cleared in hardware. Then The output is set to 0 (which is inactive).
Once .disable() => tegra_pwm_disable() gets invoked, enable bit is cleared and hence PWM will possess no output signal.tegra_pwm_config() will be invoked for any new configuration request.
Thanks & Regards,
Sandipan
Quoted 7 lines
Best regards
Uwe--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |
Hello,
Quoted 18 lines · Sandipan Patra
Quoted 18 lines · Sandipan Patra
Quoted 16 lines
Quoted 8 lines · Sandipan Patra
Quoted 6 lines
Added support for dynamic clock freq configuration in pwm kernel driver. Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm
frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is supported by clock source.Quoted 4 lines
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?Yes, frequency can be changed anytime but by the same process who has acquired the channel. So if a process is already running/using the channel, same process can only modify the frequency.
Quoted 8 lines
Quoted 3 lines
How is this enforced? Does some other peripheral get its input clock from the clock in question? What is the motivation to modify the frequency other than modifying the PWM output?
PWM instance uses a derived clock and sets the divider for further division of rate. Regarding modifying frequency: it was my wrong interpretation. I mean, to modify the PWM output the driver first sets the clock rate which allows to configure the requested PWM output.
The point here is: It should not happen that some other driver modifies a clock that results in a change of the output wave form. Also ideally if the PWM is running you should not modify the clock as this results in a non-atomic update. this is however not always possible and there is no general guideline what to do then. In practise it probably matters only little.
Quoted 15 lines
Quoted 15 lines
Quoted 14 lines
Quoted 11 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 98
Quoted 8 lines
drivers/pwm/pwm-tegra.c +8
-0+/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;Related to my question above: What happens if the rate increases after this check?
Discussed above with my understanding. Please help me understand if you are referring to any other possibilities that rate can be changed.
Quoted 6 lines
Quoted 2 lines
The goal to reach is: The only way to modify the PWM output should be to call
pwm_apply_state()(or its legacy relatives).I see with current settings, pwm output gets modified by .config() which comes from
pwm_apply_state(). I think it suffices the purpose or I am still missing anything?
I assume, you don't miss something.
Quoted 91 lines
Quoted 38 lines
Quoted 15 lines
Quoted 7 lines
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
NSEC_PER_SEC/period_ns> (max_frequency>>PWM_DUTY_WIDTH)Quoted 7 lines
This is equivalent to
period_ns<=NSEC_PER_SEC/ (max_frequency>>PWM_DUTY_WIDTH)where the right side is constant per PWM type. (Rounding might need addressing.)
Quoted 6 lines
I will update this calculation in the probe since
max_frequencyvalue is Different for each chip. Also please note that at this point the rate is not the actual pwm output rate. It's just a reference for what should be the source clock rate and then requested withclk_set_rate(); Actual rounding is required while setting pwm controller output rate is done later down in same function.I think I understood. Will check again in your next patch round.
Quoted 7 lines
Quoted 6 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 127
Quoted 4 lines
drivers/pwm/pwm-tegra.c +4
-0+* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe. I don't understand that. If
Quoted 7 lines
The if part is for SoCs which have single channel per pwm instance. i.e. T186,
T194 etc. For controllers with single channel, dynamic clock rate configuration is possible. The other part is for legacy controller which has multiple channels for single pwm instance. The pwm controllers having multiple channels share the source clock. So it does not allow dynamic clock configuration since it will affect users on theQuoted 5 lines
other channels.
The usual approach here is to allow changes iff all other channels are off or unused.
This is handled in the if part, where pwm instances have only one channel and only the dynamic clock configuration can be done. On the other side (under else part), the rate is stored during probe and it does not get modified during run time.
Quoted 20 lines
Quoted 20 lines
Quoted 20 lines
Quoted 7 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz = DIV_ROUND_CLOSEST_ULL(100ULL * NSEC_PER_SEC,
period_ns);I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8- bit DUTY value. There is an internal counter incrementing by one each (SCALE +
1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.So we have:
Quoted 8 lines
Quoted 6 lines
Quoted 4 lines
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
Yes. Right.
Ideally this would be described in a code comment.
Ok.
I will add adequate comments to help providing the register insights.Quoted 10 lines
Quoted 9 lines
Quoted 3 lines
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
Yes, PWM controller is capable to provide 100% duty cycle. Bits 30:16 are dedicated for pulse width out of which only 24:16 (9 bits) are used. Only 8 bits are usable [23:16] for varying pulse width. To achieve 100% duty cycle, Bit [24] needs to be programmed of this register to 1'b1.
Quoted 6 lines
Quoted 3 lines
This needs to be documented in a driver comment to be understandable for people being interested in this driver later.
Sure. As stated above, I will add the details in code comment. And for further Understanding Tegra documents and specifications can be followed.
If they are publically available, having a link at the top of the driver would be great.
Quoted 4 lines
Quoted 2 lines
If Bit[24] is 1, should [23:16] be zero, or is it "don't care" then?
Once the 24th bit is set, all other bits are considered to be don't care.
ok.
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 5 lines
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
Yes, you are right. The comment needs a correction. It will be plus 1 instead of minus 1. I will update the comment in the follow up patch. Otherwise the calculation is correct.
rate =DIV_ROUND_CLOSEST_ULL(100ULL * rate, hz); here rate is the divider value to be set.
Quoted 8 lines
Quoted 6 lines
If a certain duty+period is requested the driver is supposed to provide an output such that:
implemented_period = max{ possible periods <= requested period } implemented_duty = max{ possible duty <= requested duty }I am not clear if I understood the question correctly.
It was not a question :-)
Quoted 2 lines
implemented_period= max{ possible periods <= requested period } should it be, min { possible periods, requested period } ?
To put my expression in words: pick the maximum of the possible periods that are less or equal to the requested value. Maybe this is better understandable:
max { x ∊ implementablePeriods | x <= requestedPeriod }?
Quoted 6 lines
If you are asking for requested parameters to fall inside range, this is taken care at below checks.
if (period_ns<min_period_ns) //lower bound
And if (rate >>PWM_SCALE_WIDTH) //higher boundIf I am not clear with the question, please help me understanding.
Also not sure if your problem is resolved with my words. I hope so, please ask if something is still unclear. Maybe also look at the PWM_DEBUG checks to understand.
Quoted 6 lines
Quoted 3 lines
so I think
DIV_ROUND_CLOSEST_ULLis wrong.
(If the driver provided the modern callback instead of .config/.enable/.disableCONFIG_PWM_DEBUGwould help you here.)FYI, I will further be working on a separate change sets for tegra pwm driver to use atomic callbacks.
That's good. If you do these first, you can benefit from PWM_DEBUG checks.
Quoted 14 lines
Quoted 5 lines
Quoted 5 lines
Quoted 4 lines
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the currently running period?
Quoted 8 lines
Quoted 2 lines
Yes, it allows to write the bit during any active and inactive time of the width. Hence the pwm gets disabled as soon as the enable bit is set to 0.
OK, so the output stops oscillating as soon as the
PWM_ENABLEbit is cleared in hardware. How does the output behave then? (Does the output become inactive? Or does it drive the output level where it just happens to be?) I assume that the register write integra_pwm_config()also results in aborting the currently running period and start of a new one with the new settings?
Quoted 5 lines
Yes, the output stops as soon as the
PWM_ENABLEbit is cleared in hardware. Then The output is set to 0 (which is inactive).
Once .disable() =>tegra_pwm_disable()gets invoked, enable bit is cleared and hence PWM will possess no output signal.tegra_pwm_config()will be invoked for any new configuration request.
Some drivers already have a "Limitations" section in their header. Please take a look at the existing examples and provide something similar. (Note you still didn't answer "How does a running PWM behave when the register is updated? Does it complete the currently running period?". I assume the answer to the second question is "No" (and the first is only there for rhetoric reasons).)
Best regards
Uwe
Signature · 2 lines
Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | https://www.pengutronix.de/ |
Hello,
Quoted 216 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Friday, April 17, 2020 7:20 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Hello,
Quoted 3 lines · Sandipan Patra
Quoted 3 lines · Sandipan Patra
Quoted 2 lines
Quoted 2 lines · Sandipan Patra
Quoted 1 line
Added support for dynamic clock freq configuration in pwm kernel
driver.
Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
Quoted 5 lines
Earlier the pwm driver used to cache boot time clock rate by pwm clock parent during probe. Hence dynamically changing pwm frequency was not possible for all the possible ranges. With this change, dynamic calculation is enabled and it is able to set the requested period from sysfs knob provided the value is
supported by clock source.
Quoted 10 lines
Quoted 10 lines
Quoted 9 lines
Quoted 5 lines
Without having looked closely at the patch (yet), just for my
understanding: If the PWM is running and the frequency changes, the output changes, too, right? If so, do we need a notifier that prevents a frequency change when the PWM is running?Yes, frequency can be changed anytime but by the same process who has acquired the channel. So if a process is already running/using the channel, same process can only modify the frequency.
Quoted 5 lines
Quoted 3 lines
How is this enforced? Does some other peripheral get its input clock from the clock in question? What is the motivation to modify the frequency other than modifying the PWM output?
PWM instance uses a derived clock and sets the divider for further division of
rate.
Quoted 3 lines
Regarding modifying frequency: it was my wrong interpretation. I mean, to modify the PWM output the driver first sets the clock rate which allows to configure the requested PWM output.
The point here is: It should not happen that some other driver modifies a clock that results in a change of the output wave form. Also ideally if the PWM is running you should not modify the clock as this results in a non-atomic update. this is however not always possible and there is no general guideline what to do then. In practise it probably matters only little.
Quoted 15 lines
Quoted 15 lines
Quoted 14 lines
Quoted 11 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 98
Quoted 8 lines
drivers/pwm/pwm-tegra.c +8
-0+/* +* Period in nano second has to be <= highest allowed period +* based on the max clock rate of the pwm controller. +* +* higher limit = max clock limit >> PWM_DUTY_WIDTH +*/ +if (rate > (pc->soc->max_frequency >>PWM_DUTY_WIDTH )) +return -EINVAL ;Related to my question above: What happens if the rate increases after this check?
Discussed above with my understanding. Please help me understand if you are referring to any other possibilities that rate can be changed.
Quoted 7 lines
Quoted 3 lines
The goal to reach is: The only way to modify the PWM output should be to call
pwm_apply_state()(or its legacy relatives).I see with current settings, pwm output gets modified by .config() which comes from
pwm_apply_state(). I think it suffices the purpose or I am still missing anything?I assume, you don't miss something.
Quoted 95 lines
Quoted 41 lines
Quoted 17 lines
Quoted 8 lines
Also the division above is just done to compare the requested period value with the allowed range.
Your check is:
NSEC_PER_SEC/period_ns> (max_frequency>>PWM_DUTY_WIDTH)Quoted 8 lines
This is equivalent to
period_ns<=NSEC_PER_SEC/ (max_frequency>>PWM_DUTY_WIDTH)where the right side is constant per PWM type. (Rounding might need
addressing.)Quoted 6 lines
I will update this calculation in the probe since
max_frequencyvalue is Different for each chip. Also please note that at this point the rate is not the actual pwm output rate. It's just a reference for what should be the source clock rate and then requested withclk_set_rate(); Actual rounding is required while setting pwm controller output rate is done later down in same function.I think I understood. Will check again in your next patch round.
Quoted 7 lines
Quoted 6 lines
drivers/pwm/pwm-tegra.c static int tegra_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm, · line 127
Quoted 4 lines
drivers/pwm/pwm-tegra.c +4
-0+* clk_set_rate() can not be called again in config because +* T210 or any prior chip supports one pwm-controller and +* multiple channels. Hence in this case cached clock rate +* will be considered which was stored during probe. I don't understand that. If
Quoted 8 lines
The if part is for SoCs which have single channel per pwm instance. i.e. T186,
T194 etc. For controllers with single channel, dynamic clock rate configuration is possible. The other part is for legacy controller which has multiple channels for single pwm instance. The pwm controllers having multiple channels share the source clock. So it does not allow dynamic clock configuration since it will affect users on theQuoted 5 lines
other channels.
The usual approach here is to allow changes iff all other channels are off or unused.
This is handled in the if part, where pwm instances have only one channel and only the dynamic clock configuration can be done. On the other side (under else part), the rate is stored during probe and it does not get modified during run time.
Quoted 20 lines
Quoted 20 lines
Quoted 20 lines
Quoted 7 lines
drivers/pwm/pwm-tegra.c +3
-0+*/ + rate = pc->clk_rate >>PWM_DUTY_WIDTH ; + }/* Consider precision in PWM_SCALE_WIDTH rate calculation */ hz = DIV_ROUND_CLOSEST_ULL(100ULL * NSEC_PER_SEC,
period_ns);I took a deeper look into the driver now. Just to ensure, I understood the PWMs behaviour right:
There is an ENABLE bit (with obvious semantics), a 13-bit SCALE value and an 8- bit DUTY value. There is an internal counter incrementing by one each (SCALE +
1) clock cycles and resets at 256. The counter going from 0 to 256 defines the period length. On counter reset the output gets active and on reaching DUTY the output gets inactive.So we have:
Quoted 8 lines
Quoted 6 lines
Quoted 4 lines
.period = 256 * (SCALE + 1) / clkrate .duty_cycle = DUTY * (SCALE + 1) / clkrate
Right?
Yes. Right.
Ideally this would be described in a code comment.
Ok.
I will add adequate comments to help providing the register insights.Quoted 11 lines
Quoted 10 lines
Quoted 3 lines
- When .duty_ns == .period the assignment of DUTY overflows. (Can the PWM provide 100% duty cycle at all?)
Yes, PWM controller is capable to provide 100% duty cycle. Bits 30:16 are dedicated for pulse width out of which only 24:16 (9
bits) are used. Only 8 bits are usable [23:16] for varying pulse width. To achieve 100% duty cycle, Bit [24] needs to be programmed of this register to 1'b1.Quoted 6 lines
Quoted 3 lines
This needs to be documented in a driver comment to be understandable for people being interested in this driver later.
Sure. As stated above, I will add the details in code comment. And for further Understanding Tegra documents and specifications can be followed.
If they are publically available, having a link at the top of the driver would be great.
Quoted 4 lines
Quoted 2 lines
If Bit[24] is 1, should [23:16] be zero, or is it "don't care" then?
Once the 24th bit is set, all other bits are considered to be don't care.
ok.
Quoted 12 lines
Quoted 12 lines
Quoted 11 lines
Quoted 5 lines
- The comment "Since the actual PWM divider is the register's frequency divider field minus 1, we need to decrement to get the correct value to write to the register." seems wrong. If I understand correctly, we need to do s/minus/plus/. If the register holds a 0, the divider isn't -1 for sure?!
Yes, you are right. The comment needs a correction. It will be plus 1 instead of minus 1. I will update the comment in the follow up patch. Otherwise the calculation is correct.
rate =DIV_ROUND_CLOSEST_ULL(100ULL * rate, hz); here rate is the divider value to be set.Quoted 8 lines
Quoted 6 lines
If a certain duty+period is requested the driver is supposed to provide an output such that:
implemented_period = max{ possible periods <= requested period } implemented_duty = max{ possible duty <= requested duty }I am not clear if I understood the question correctly.
It was not a question :-)
Quoted 2 lines
implemented_period= max{ possible periods <= requested period } should it be, min { possible periods, requested period } ?
Quoted 7 lines
To put my expression in words: pick the maximum of the possible periods that are less or equal to the requested value. Maybe this is better understandable:
max { x ∊ implementablePeriods | x <= requestedPeriod }?
I think I got your question.
Should tegra_pwm_config() not return error (EINVAL) when the requested period is invalid but it should configure to a nearest possible value?
Quoted 44 lines
Quoted 7 lines
If you are asking for requested parameters to fall inside range, this is taken care at below checks.
if (period_ns<min_period_ns) //lower bound And if (rate >>PWM_SCALE_WIDTH) //higher boundIf I am not clear with the question, please help me understanding.
Also not sure if your problem is resolved with my words. I hope so, please ask if something is still unclear. Maybe also look at the
PWM_DEBUGchecks to understand.Quoted 6 lines
Quoted 3 lines
so I think
DIV_ROUND_CLOSEST_ULLis wrong.
(If the driver provided the modern callback instead of .config/.enable/.disableCONFIG_PWM_DEBUGwould help you here.)FYI, I will further be working on a separate change sets for tegra pwm driver to use atomic callbacks.
That's good. If you do these first, you can benefit from
PWM_DEBUGchecks.Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
Quoted 4 lines
How does the PWM behave when it gets disabled? Does it complete the currently running period? Does the output stop at the inactive level, or where it just happens to be? How does a running PWM behave when the register is updated? Does it complete the
currently running period?
Quoted 3 lines
Quoted 3 lines
Quoted 3 lines
Yes, it allows to write the bit during any active and inactive time of the width. Hence the pwm gets disabled as soon as the enable bit is
set to 0.
Quoted 6 lines
Quoted 6 lines
OK, so the output stops oscillating as soon as the
PWM_ENABLEbit is cleared in hardware. How does the output behave then? (Does the output become inactive? Or does it drive the output level where it just happens to be?) I assume that the register write integra_pwm_config()also results in aborting the currently running period andstart of a new one with the new settings?
Quoted 6 lines
Yes, the output stops as soon as the
PWM_ENABLEbit is cleared in hardware. Then The output is set to 0 (which is inactive). Once .disable() =>tegra_pwm_disable()gets invoked, enable bit is cleared and hence PWM will possess no output signal.tegra_pwm_config()will be invoked for any new configuration request.
Quoted 6 lines
Some drivers already have a "Limitations" section in their header. Please take a look at the existing examples and provide something similar. (Note you still didn't answer "How does a running PWM behave when the register is updated? Does it complete the currently running period?". I assume the answer to the second question is "No" (and the first is only there for rhetoric reasons).)
1. I will add the below comments as Limitations:
- When PWM is disabled, the output is driven to 0 and
- It does not allow the current PWM period to complete and stops abruptly.
2. Yes. Right.
If the register is updated while the pwm is running, It does not complete the currently running period.
Hope this clarifies the concerns.
If they are clarified and acknowledged, I will be able to send the Patch for V2.
Thanks & Regards,
Sandipan
Quoted 6 lines
Best regards
Uwe--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |
Hello,
Quoted 11 lines · Sandipan Patra
Quoted 7 lines
To put my expression in words: pick the maximum of the possible periods that are less or equal to the requested value. Maybe this is better understandable:
max { x ∊ implementablePeriods | x <= requestedPeriod }?
I think I got your question.
Shouldtegra_pwm_config()not return error (EINVAL) when the requested period is invalid but it should configure to a nearest possible value?
If you cannot configure according to the above rule, yes, return an error code. EINVAL is the usual one I think (some also return ERANGE).
Quoted 14 lines
Quoted 6 lines
Quoted 5 lines
Yes, the output stops as soon as the
PWM_ENABLEbit is cleared in hardware. Then The output is set to 0 (which is inactive). Once .disable() =>tegra_pwm_disable()gets invoked, enable bit is cleared and hence PWM will possess no output signal.tegra_pwm_config()will be invoked for any new configuration request.Quoted 6 lines
Some drivers already have a "Limitations" section in their header. Please take a look at the existing examples and provide something similar. (Note you still didn't answer "How does a running PWM behave when the register is updated? Does it complete the currently running period?". I assume the answer to the second question is "No" (and the first is only there for rhetoric reasons).)
1. I will add the below comments as Limitations:
Review
Quoted 1 line
(quoted diff) +0
-1- When PWM is disabled, the output is driven to 0 and
In fact, this is a good property. So the only problem is, that for both stop and reconfiguration the currently running period isn't completed.
Best regards
Uwe
Signature · 2 lines
Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | https://www.pengutronix.de/ |
Hi Uwe,
Thanks for reviewing and providing your inputs to the changes.
The review comments are addressed in the new patch. Patch (V2) is ready to be reviewed at:
https://patchwork.ozlabs.org/project/linux-pwm/patch/[email protected]/
Please help reviewing further.
Thanks & Regards,
Sandipan
Quoted 59 lines
-----Original Message-----
From: Uwe Kleine-König <[email protected]>
Sent: Saturday, April 18, 2020 1:53 PM
To: Sandipan Patra <[email protected]>
Cc: Thierry Reding <[email protected]>; [email protected]; Jonathan Hunter <[email protected]>; Bibek Basu <[email protected]>; Laxman Dewangan <[email protected]>; [email protected]; [email protected]; [email protected]; linux- [email protected]
Subject: Re: [PATCH] pwm: tegra: dynamic clk freq configuration by PWM driverExternal email: Use caution opening links or attachments
Hello,
Quoted 5 lines · Sandipan Patra
Quoted 5 lines
To put my expression in words: pick the maximum of the possible periods that are less or equal to the requested value. Maybe this is better
understandable:Quoted 7 lines
Quoted 3 lines
max { x ∊ implementablePeriods | x <= requestedPeriod }?
I think I got your question.
Shouldtegra_pwm_config()not return error (EINVAL) when the requested period is invalid but it should configure to a nearest possible value?If you cannot configure according to the above rule, yes, return an error code. EINVAL is the usual one I think (some also return ERANGE).
Quoted 14 lines
Quoted 6 lines
Quoted 5 lines
Yes, the output stops as soon as the
PWM_ENABLEbit is cleared in hardware. Then The output is set to 0 (which is inactive). Once .disable() =>tegra_pwm_disable()gets invoked, enable bit is cleared and hence PWM will possess no output signal.tegra_pwm_config()will be invoked for any new configuration request.Quoted 7 lines
Some drivers already have a "Limitations" section in their header. Please take a look at the existing examples and provide something similar. (Note you still didn't answer "How does a running PWM behave when the register is updated? Does it complete the currently running period?". I assume the answer to the second question is "No" (and the first is only there for rhetoric reasons).)
Quoted 2 lines
1. I will add the below comments as Limitations:
- When PWM is disabled, the output is driven to 0 andIn fact, this is a good property. So the only problem is, that for both stop and reconfiguration the currently running period isn't completed.
Best regards
Uwe--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |