net: mana: Assigning IRQ affinity on HT cores

PATCH In review Souradeep Chakrabarti 4 participants 14 messages Dec 8, 2023 – Dec 12, 2023

Subsystems (5)
lore
Share & tools
lore
#0 lore raw

PATCH v5 1/1 net: mana: Assigning IRQ affinity on HT cores

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

---
V4 -> V5:
* Fixed use of for_each_numa_hop_mask in irq_setup, by using visited_cpus to mask previous node mask.
* Changed the way IRQ0 is gettng assigned, to assign it a separate CPU if possible rather than assigning it to a already assigned CPU.
* Added Suggested-by tag.

V3 -> V4:
* Used for_each_numa_hop_mask() macro and simplified the code. Thanks to Yury Norov for the suggestion.
* Added code to assign hwc irq separately in mana_gd_setup_irqs.

V2 -> V3:
* Created a helper function to get the next NUMA with CPU.
* Added some error checks for unsuccessful memory allocation.
* Fixed some comments on the code.

V1 -> V2:
* Simplified the code by removing filter_mask_list and using avail_cpus.
* Addressed infinite loop issue when there are numa nodes with no CPUs.
* Addressed uses of local numa node instead of 0 to start.
* Removed uses of BUG_ON.
* Placed cpus_read_lock in parent function to avoid num_online_cpus to get changed before function finishes the affinity assignment.

---
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +83 -9
index 6367de0c2c2e..18e8908c5d29 100644
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;
+				cpumask_andnot(cpus, cpus, topology_sibling_cpumask(cpu));
+				++cnt;
+			}
+		}
+		prev = next;
+	}
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+
 static int mana_gd_setup_irqs(struct pci_dev *pdev)
 {
-	unsigned int max_queues_per_port = num_online_cpus();
 	struct gdma_context *gc = pci_get_drvdata(pdev);
+	unsigned int max_queues_per_port;
 	struct gdma_irq_context *gic;
 	unsigned int max_irqs, cpu;
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
 	int err, i = 0, j;
 
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
 	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
 		max_queues_per_port = MANA_MAX_NUM_QUEUES;
 
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int), GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
 	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
 				   GFP_KERNEL);
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index], mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
 	return 0;
 
 free_irq:
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;
 free_irq_vector:
+	cpus_read_unlock();
 	pci_free_irq_vectors(pdev);
 	return err;
 }
Signature · 1 line
2.34.1
#1 lore raw
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

Quoted 3 lines

---

[...]

Quoted 8 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 8 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 13 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +13 -0
+		err = -ENOMEM;
+		return err;
+	}
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

Quoted 60 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +31 -8
+				cpumask_andnot(cpus, cpus, topology_sibling_cpumask(cpu));
+				++cnt;
+			}
+		}
+		prev = next;
+	}
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+
 static int mana_gd_setup_irqs(struct pci_dev *pdev)
 {
-	unsigned int max_queues_per_port = num_online_cpus();
 	struct gdma_context *gc = pci_get_drvdata(pdev);
+	unsigned int max_queues_per_port;
 	struct gdma_irq_context *gic;
 	unsigned int max_irqs, cpu;
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
 	int err, i = 0, j;
 
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
 	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
 		max_queues_per_port = MANA_MAX_NUM_QUEUES;
 
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int), GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
 	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
 				   GFP_KERNEL);
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

Quoted 40 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +17 -1
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index], mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
 	return 0;
 
 free_irq:
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;
 free_irq_vector:
+	cpus_read_unlock();
 	pci_free_irq_vectors(pdev);
 	return err;
 }
Signature · 1 line
2.34.1
#2 lore raw

Few more nits

Quoted 41 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

Quoted 3 lines

---

[...]

Quoted 8 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

Quoted 4 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1253

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {

alloc_cpumask_var() here and below, because you initialize them by copying

Quoted 7 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1265

Quoted 8 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+		err = -ENOMEM;
+		return err;
+	}
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {

OK, if you can't increment inside for-loop, I'd switch it to a while-loop:

                w = cpumask_weight(curr);
                cnt = 0;

		while (cnt < w) {
Quoted 10 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

Quoted 6 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1276

Quoted 6 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +6 -0
+				cpumask_andnot(cpus, cpus, topology_sibling_cpumask(cpu));
+				++cnt;
+			}
+		}
+		prev = next;
+	}

Don't hesitate to add even more vertical spacing. It's like: "take a breath folks, this section is done". :)

Quoted 108 lines
Quoted 54 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +25 -8
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+
 static int mana_gd_setup_irqs(struct pci_dev *pdev)
 {
-	unsigned int max_queues_per_port = num_online_cpus();
 	struct gdma_context *gc = pci_get_drvdata(pdev);
+	unsigned int max_queues_per_port;
 	struct gdma_irq_context *gic;
 	unsigned int max_irqs, cpu;
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
 	int err, i = 0, j;
 
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
 	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
 		max_queues_per_port = MANA_MAX_NUM_QUEUES;
 
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int), GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
 	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
 				   GFP_KERNEL);
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

Quoted 40 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +17 -1
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index], mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
 	return 0;
 
 free_irq:
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;
 free_irq_vector:
+	cpus_read_unlock();
 	pci_free_irq_vectors(pdev);
 	return err;
 }
Signature · 1 line
2.34.1
#6 lore raw
In reply to Yury Norov
Quoted 8 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Let's consider this topology:

Node 0 1
Core 0 1 2 3
CPU 0 1 2 3 4 5 6 7

Before

 IRQ     Nodes   Cores   CPUs
 0       1       0       0
 1       1       1       2
 2       1       0       1
 3       1       1       3
 4       2       2       4
 5       2       3       6
 6       2       2       5
 7       2       3       7

Now

 IRQ     Nodes   Cores   CPUs
 0       1       0       0-1
 1       1       1       2-3
 2       1       0       0-1
 3       1       1       2-3
 4       2       2       4-5
 5       2       3       6-7
 6       2       2       4-5
 7       2       3       6-7
Quoted 8 lines
Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

I have used ntttcp for performance analysis, by perf I had meant performance analysis. I have used ntttcp with following parameters
ntttcp -r -m 64 <receiver>

ntttcp -s <receiver side ip address> -m 64 <sender>
Both the VMs are in same Azure subnet and private IP address is used. MTU and tcp buffer is set accordingly and number of channels are set using ethtool accordingly for best performance. Also irqbalance was disabled.
https://github.com/microsoft/ntttcp-for-linux
https://learn.microsoft.com/en-us/azure/virtual-network/virtual-network-bandwidth-testing?tabs=linux

Quoted 18 lines
Quoted 4 lines

---

[...]

Quoted 11 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
Quoted 6 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

This is the local numa node, from where to start hopping.
Please see how we are calling irq_setup(). We are passing the array of allocated irqs, total number of irqs allocated, and the local numa node to the device.

Quoted 11 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 9 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);

Will fix it in next version. Thanks for pointing.

Quoted 18 lines
Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+		err = -ENOMEM;
+		return err;
+	}

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can not be passed.

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)

	return nvec;
Quoted 66 lines
Quoted 66 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +36 -8
+				cpumask_andnot(cpus, cpus, topology_sibling_cpumask(cpu));
+				++cnt;
+			}
+		}
+		prev = next;
+	}
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+
 static int mana_gd_setup_irqs(struct pci_dev *pdev)
 {
-	unsigned int max_queues_per_port = num_online_cpus();
 	struct gdma_context *gc = pci_get_drvdata(pdev);
+	unsigned int max_queues_per_port;
 	struct gdma_irq_context *gic;
 	unsigned int max_irqs, cpu;
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
 	int err, i = 0, j;
 
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
 	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
 		max_queues_per_port = MANA_MAX_NUM_QUEUES;
 
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int), GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
 	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
 				   GFP_KERNEL);
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

The reason I have picked cpumask_local_spread here, is that, the gc->numa_node can be a memory only node, in that case we need to jump to next node to get the CPU. Which cpumask_local_spread() using sched_numa_find_nth_cpu() takes care off.

Quoted 41 lines
Quoted 41 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +17 -1
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index], mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
 	return 0;
 
 free_irq:
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;
 free_irq_vector:
+	cpus_read_unlock();
 	pci_free_irq_vectors(pdev);
 	return err;
 }
Signature · 1 line
2.34.1
#3 lore raw
In reply to Yury Norov
Quoted 44 lines · Yury Norov

Few more nits

Quoted 41 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

Quoted 3 lines

---

[...]

Quoted 8 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

Quoted 7 lines
Quoted 4 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1253

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {

alloc_cpumask_var() here and below, because you initialize them by copying

I have used zalloc here as prev gets initialized after the first hop, before that it may contain unwanted values, which may impact cpumask_andnot(curr, next, prev). Regarding curr I will change it to alloc_cpumask_var().
Please let me know if that sounds right.

Quoted 19 lines
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1265

Quoted 8 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+		err = -ENOMEM;
+		return err;
+	}
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {

OK, if you can't increment inside for-loop, I'd switch it to a while-loop:

Quoted 3 lines
                w = cpumask_weight(curr);
                cnt = 0;

Thanks will change it to while loop.

Quoted 12 lines
		while (cnt < w) {
Quoted 10 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

Quoted 10 lines
Quoted 6 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1276

Quoted 6 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +6 -0
+				cpumask_andnot(cpus, cpus, topology_sibling_cpumask(cpu));
+				++cnt;
+			}
+		}
+		prev = next;
+	}

Don't hesitate to add even more vertical spacing. It's like: "take a breath folks, this section is done". :)

Sure will add in next version.

Quoted 108 lines
Quoted 108 lines
Quoted 54 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +25 -8
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+
 static int mana_gd_setup_irqs(struct pci_dev *pdev)
 {
-	unsigned int max_queues_per_port = num_online_cpus();
 	struct gdma_context *gc = pci_get_drvdata(pdev);
+	unsigned int max_queues_per_port;
 	struct gdma_irq_context *gic;
 	unsigned int max_irqs, cpu;
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
 	int err, i = 0, j;
 
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
 	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
 		max_queues_per_port = MANA_MAX_NUM_QUEUES;
 
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int), GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
 	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
 				   GFP_KERNEL);
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

Quoted 40 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +17 -1
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index], mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
 	return 0;
 
 free_irq:
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;
 free_irq_vector:
+	cpus_read_unlock();
 	pci_free_irq_vectors(pdev);
 	return err;
 }
Signature · 1 line
2.34.1
#4 lore raw
Quoted 52 lines · Souradeep Chakrabarti
Quoted 44 lines · Yury Norov

Few more nits

Quoted 41 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

Quoted 3 lines

---

[...]

Quoted 8 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

Quoted 7 lines
Quoted 4 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1253

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {

alloc_cpumask_var() here and below, because you initialize them by copying

Quoted 4 lines

I have used zalloc here as prev gets initialized after the first hop, before that it may contain unwanted values, which may impact cpumask_andnot(curr, next, prev). Regarding curr I will change it to alloc_cpumask_var().
Please let me know if that sounds right.

What? prev is initialized at declaration:

        const struct cpumask *next, *prev = cpu_none_mask;
#7 lore raw
In reply to Souradeep Chakrabarti
Quoted 10 lines · Souradeep Chakrabarti
Quoted 8 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Let's consider this topology:

Not here - in commit message, please.

Quoted 17 lines

Node 0 1
Core 0 1 2 3
CPU 0 1 2 3 4 5 6 7

Before

 IRQ     Nodes   Cores   CPUs
 0       1       0       0
 1       1       1       2
 2       1       0       1
 3       1       1       3
 4       2       2       4
 5       2       3       6
 6       2       2       5
 7       2       3       7

Now

Quoted 9 lines
 IRQ     Nodes   Cores   CPUs
 0       1       0       0-1
 1       1       1       2-3
 2       1       0       0-1
 3       1       1       2-3
 4       2       2       4-5
 5       2       3       6-7
 6       2       2       4-5
 7       2       3       6-7

If you decided to take my wording, please give credits.

Quoted 12 lines
Quoted 8 lines
Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

I have used ntttcp for performance analysis, by perf I had meant performance analysis. I have used ntttcp with following parameters
ntttcp -r -m 64 <receiver>

Quoted 6 lines

ntttcp -s <receiver side ip address> -m 64 <sender>
Both the VMs are in same Azure subnet and private IP address is used. MTU and tcp buffer is set accordingly and number of channels are set using ethtool accordingly for best performance. Also irqbalance was disabled.
https://github.com/microsoft/ntttcp-for-linux
https://learn.microsoft.com/en-us/azure/virtual-network/virtual-network-bandwidth-testing?tabs=linux

OK. Can you also print the before/after outputs of ntttcp that demonstrate +15%?

Quoted 17 lines
Quoted 17 lines
Quoted 3 lines

---

[...]

Quoted 11 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
Quoted 1 line
Quoted 1 line

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1246

Quoted 1 line
drivers/net/ethernet/microsoft/mana/gdma_main.c +1 -0
+static int irq_setup(int *irqs, int nvec, int start_numa_node)

Is it intentional that irqs and nvec are signed? If not, please make them unsigned.

Quoted 8 lines
Quoted 5 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 3 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

This is the local numa node, from where to start hopping.
Please see how we are calling irq_setup(). We are passing the array of allocated irqs, total number of irqs allocated, and the local numa node to the device.

I'll ask again: you copy parameter (start_numa_node) to a local variable (next_node), and never use start_numa_node after that.

You can just use the parameter, and avoid creating local variable at all, so what for the latter exist?

The naming is confusing. I think just 'node' is OK here.

Quoted 11 lines
Quoted 10 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 8 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);

Will fix it in next version. Thanks for pointing.

And also drop 'err' - just 'return -ENOMEM'.

Quoted 18 lines
Quoted 18 lines
Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+		err = -ENOMEM;
+		return err;
+	}

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

Quoted 6 lines

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can not be passed.

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)

	return nvec;

I know that. But still it's a bug. The common convention is that if a 0-length array is passed to a function, it should not dereference the pointer.

...

Quoted 28 lines
Quoted 20 lines
Quoted 20 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -6
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

Quoted 3 lines

The reason I have picked cpumask_local_spread here, is that, the gc->numa_node can be a memory only node, in that case we need to jump to next node to get the CPU. Which cpumask_local_spread() using sched_numa_find_nth_cpu() takes care off.

OK, makes sense.

What if you need to distribute more IRQs than the number of CPUs? In that case you'd call the function many times. But because you return 0, user has no chance catch that. I think you should handle it inside the helper, or do like this:

        while (nvec) {
                distributed = irq_setup(irqs, nvec, node);
                if (distributed < 0)
                        break;

                irq += distributed;
                nvec -= distributed;
        }

Thanks,
Yury

#5 lore raw
In reply to Yury Norov
Quoted 53 lines · Yury Norov
Quoted 52 lines · Souradeep Chakrabarti
Quoted 51 lines · Yury Norov

Few more nits

Quoted 41 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

Quoted 3 lines

---

[...]

Quoted 8 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
+static int irq_setup(int *irqs, int nvec, int start_numa_node)
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

Quoted 4 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1253

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {

alloc_cpumask_var() here and below, because you initialize them by copying

Quoted 6 lines
Quoted 4 lines

I have used zalloc here as prev gets initialized after the first hop, before that it may contain unwanted values, which may impact cpumask_andnot(curr, next, prev). Regarding curr I will change it to alloc_cpumask_var().
Please let me know if that sounds right.

What? prev is initialized at declaration:

Yes, I will remove the zalloc and will change it to alloc in V6. Thanks for pointing.

Quoted 2 lines
        
        const struct cpumask *next, *prev = cpu_none_mask;
#8 lore raw
In reply to Yury Norov
Quoted 7 lines · Yury Norov
Quoted 6 lines · Souradeep Chakrabarti
Quoted 5 lines · Yury Norov
Quoted 3 lines · Souradeep Chakrabarti

Existing MANA design assigns IRQ to every CPU, including sibling hyper-threads. This may cause multiple IRQs to be active simultaneously in the same core and may reduce the network performance with RSS.

Quoted 6 lines
Quoted 4 lines
Quoted 3 lines

Can you add an IRQ distribution diagram to compare before/after behavior, similarly to what I did in the other email?

Let's consider this topology:

Not here - in commit message, please.

Okay, will do that.

Quoted 28 lines
Quoted 18 lines

Node 0 1
Core 0 1 2 3
CPU 0 1 2 3 4 5 6 7

Before

 IRQ     Nodes   Cores   CPUs
 0       1       0       0
 1       1       1       2
 2       1       0       1
 3       1       1       3
 4       2       2       4
 5       2       3       6
 6       2       2       5
 7       2       3       7

Now

Quoted 9 lines
 IRQ     Nodes   Cores   CPUs
 0       1       0       0-1
 1       1       1       2-3
 2       1       0       0-1
 3       1       1       2-3
 4       2       2       4-5
 5       2       3       6-7
 6       2       2       4-5
 7       2       3       6-7
Quoted 2 lines

If you decided to take my wording, please give credits.

Will take care of that :).

Quoted 19 lines
Quoted 12 lines
Quoted 8 lines
Quoted 5 lines

Improve the performance by assigning IRQ to non sibling CPUs in local NUMA node. The performance improvement we are getting using ntttcp with following patch is around 15 percent with existing design and approximately 11 percent, when trying to assign one IRQ in each core across NUMA nodes, if enough cores are present.

How did you measure it? In the other email you said you used perf, can you show your procedure in details?

I have used ntttcp for performance analysis, by perf I had meant performance analysis. I have used ntttcp with following parameters
ntttcp -r -m 64 <receiver>

Quoted 6 lines

ntttcp -s <receiver side ip address> -m 64 <sender>
Both the VMs are in same Azure subnet and private IP address is used. MTU and tcp buffer is set accordingly and number of channels are set using ethtool accordingly for best performance. Also irqbalance was disabled.
https://github.com/microsoft/ntttcp-for-linux
https://learn.microsoft.com/en-us/azure/virtual-network/virtual-network-bandwidth-testing?tabs=linux

Quoted 3 lines

OK. Can you also print the before/after outputs of ntttcp that demonstrate +15%?

With affinity spread like each core only 1 irq and spreading accross multiple NUMA node> 8 ./ntttcp -r -m 16
NTTTCP for Linux 1.4.0
---------------------------------------------------------
08:05:20 INFO: 17 threads created
08:05:28 INFO: Network activity progressing...
08:06:28 INFO: Test run completed.
08:06:28 INFO: Test cycle finished.
08:06:28 INFO: ##### Totals: #####

08:06:28 INFO: test duration    :60.00 seconds
08:06:28 INFO: total bytes      :630292053310
08:06:28 INFO:   throughput     :84.04Gbps
08:06:28 INFO:   retrans segs   :4
08:06:28 INFO: cpu cores        :192
08:06:28 INFO:   cpu speed      :3799.725MHz
08:06:28 INFO:   user           :0.05%
08:06:28 INFO:   system         :1.60%
08:06:28 INFO:   idle           :96.41%
08:06:28 INFO:   iowait         :0.00%
08:06:28 INFO:   softirq        :1.94%
08:06:28 INFO:   cycles/byte    :2.50
08:06:28 INFO: cpu busy (all)   :534.41%

With our new proposal

./ntttcp -r -m 16
NTTTCP for Linux 1.4.0
---------------------------------------------------------
08:08:51 INFO: 17 threads created
08:08:56 INFO: Network activity progressing...
08:09:56 INFO: Test run completed.
08:09:56 INFO: Test cycle finished.
08:09:56 INFO: ##### Totals: #####

08:09:56 INFO: test duration    :60.00 seconds
08:09:56 INFO: total bytes      :741966608384
08:09:56 INFO:   throughput     :98.93Gbps
08:09:56 INFO:   retrans segs   :6
08:09:56 INFO: cpu cores        :192
08:09:56 INFO:   cpu speed      :3799.791MHz
08:09:56 INFO:   user           :0.06%
08:09:56 INFO:   system         :1.81%
08:09:56 INFO:   idle           :96.18%
08:09:56 INFO:   iowait         :0.00%
08:09:56 INFO:   softirq        :1.95%
08:09:56 INFO:   cycles/byte    :2.25
08:09:56 INFO: cpu busy (all)   :569.22%

---------------------------------------------------------

Quoted 17 lines
Quoted 17 lines
Quoted 17 lines
Quoted 3 lines

---

[...]

Quoted 11 lines
 .../net/ethernet/microsoft/mana/gdma_main.c   | 92 +++++++++++++++++--
 1 file changed, 83 insertions(+), 9 deletions(-)
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
index 6367de0c2c2e..18e8908c5d29 100644
@@ -1243,15 +1243,56 @@ void mana_gd_free_res_map(struct gdma_resource *r)
 	r->size = 0;
 }
 
Quoted 4 lines
Quoted 1 line
Quoted 1 line

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1246

Quoted 1 line
drivers/net/ethernet/microsoft/mana/gdma_main.c +1 -0
+static int irq_setup(int *irqs, int nvec, int start_numa_node)

Is it intentional that irqs and nvec are signed? If not, please make them unsigned.

Will do it in next version.

Quoted 10 lines
Quoted 9 lines
Quoted 6 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1249

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+{
+	int w, cnt, cpu, err = 0, i = 0;
+	int next_node = start_numa_node;

What for this?

This is the local numa node, from where to start hopping.
Please see how we are calling irq_setup(). We are passing the array of allocated irqs, total number of irqs allocated, and the local numa node to the device.

Quoted 7 lines

I'll ask again: you copy parameter (start_numa_node) to a local variable (next_node), and never use start_numa_node after that.

You can just use the parameter, and avoid creating local variable at all, so what for the latter exist?

The naming is confusing. I think just 'node' is OK here.

Thanks, I wll not use the extra variable next_node.

Quoted 11 lines
Quoted 11 lines
Quoted 11 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 9 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -0
+	const struct cpumask *next, *prev = cpu_none_mask;
+	cpumask_var_t curr, cpus;
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {
                free(curr);
Quoted 4 lines
Quoted 1 line

Will fix it in next version. Thanks for pointing.

And also drop 'err' - just 'return -ENOMEM'.

Will fix it in next revision.

Quoted 21 lines
Quoted 21 lines
Quoted 18 lines
Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+		err = -ENOMEM;
+		return err;
+	}

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 10 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -0
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can not be passed.

Quoted 8 lines
Quoted 3 lines

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)

	return nvec;

I know that. But still it's a bug. The common convention is that if a 0-length array is passed to a function, it should not dereference the pointer.

I will add one if check in the begining of irq_setup() to verify the pointer and the nvec number.

Quoted 41 lines

...

Quoted 28 lines
Quoted 20 lines
Quoted 20 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +10 -6
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+
+			/* If number of IRQ is one extra than number of online CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
Quoted 8 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev *pdev) · line 1353

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);

I already mentioned that: if i == 0, you don't need to spread, just pick 1st cpu from node.

Quoted 3 lines

The reason I have picked cpumask_local_spread here, is that, the gc->numa_node can be a memory only node, in that case we need to jump to next node to get the CPU. Which cpumask_local_spread() using sched_numa_find_nth_cpu() takes care off.

OK, makes sense.

What if you need to distribute more IRQs than the number of CPUs? In that case you'd call the function many times. But because you return 0, user has no chance catch that. I think you should handle it inside the helper, or do like this:

Quoted 8 lines
        while (nvec) {
                distributed = irq_setup(irqs, nvec, node);
                if (distributed < 0)
                        break;

                irq += distributed;
                nvec -= distributed;
        }

We can not have irqs more greater than 1 of num of online CPUs, as we are setting it inside cpu_read_lock() with num_online_cpus().
We can have minimum 2 IRQs and max number_online_cpus() +1 or 64, which is maximum supported IRQs per port.

1295         cpus_read_lock();
1296         max_queues_per_port = num_online_cpus();
1297         if (max_queues_per_port > MANA_MAX_NUM_QUEUES)

1298 max_queues_per_port = MANA_MAX_NUM_QUEUES;
1299
1300 /* Need 1 interrupt for the Hardware communication Channel (HWC) */
1301 max_irqs = max_queues_per_port + 1;
1302
1303 nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
1304 if (nvec < 0)
1305 return nvec;

Quoted 3 lines

Thanks,
Yury

#9 lore raw
Quoted 20 lines
Quoted 20 lines
Quoted 19 lines
Quoted 4 lines
Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +4 -0
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
Quoted 9 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 5 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -0
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i], topology_sibling_cpumask(cpu));
+				if (++i == nvec)
+					goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can not be passed.

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)

	return nvec;
Quoted 6 lines
Quoted 4 lines

I know that. But still it's a bug. The common convention is that if a 0-length array is passed to a function, it should not dereference the pointer.

I will add one if check in the begining of irq_setup() to verify the pointer and the nvec number.

Yes you can, but what for? This is an error anyways, and you don't care about early return. So instead of adding and bearing extra logic, I'd just swap 2 lines of existing code.

#10 lore raw
Quoted 48 lines

-----Original Message-----
From: Yury Norov <[email protected]>
Sent: Tuesday, December 12, 2023 10:04 PM
To: Souradeep Chakrabarti <[email protected]>
Cc: KY Srinivasan <[email protected]>; Haiyang Zhang <[email protected]>; [email protected]; Dexuan Cui <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; Long Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; linux- [email protected]; Souradeep Chakrabarti <[email protected]>; Paul Rosswurm <[email protected]>
Subject: [EXTERNAL] Re: [PATCH V5 net-next] net: mana: Assigning IRQ affinity on HT cores

[Some people who received this message don't often get email from [email protected]. Learn why this is important at
https://aka.ms/LearnAboutSenderIdentification ]

Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r)

Quoted 7 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +7 -0
+     rcu_read_lock();
+     for_each_numa_hop_mask(next, next_node) {
+             cpumask_andnot(curr, next, prev);
+             for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+                     cpumask_copy(cpus, curr);
+                     for_each_cpu(cpu, cpus) {
+                             irq_set_affinity_and_hint(irqs[i],

topology_sibling_cpumask(cpu));

Quoted 8 lines
Quoted 8 lines
Quoted 8 lines
Quoted 6 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1270

Quoted 2 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +2 -0
+                             if (++i == nvec)
+                                     goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can

not be passed.

Quoted 9 lines
Quoted 9 lines
Quoted 4 lines

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)
return nvec;

I know that. But still it's a bug. The common convention is that if a 0-length array is passed to a function, it should not dereference the pointer.

Quoted 6 lines
Quoted 2 lines

I will add one if check in the begining of irq_setup() to verify the pointer and the nvec number.

Yes you can, but what for? This is an error anyways, and you don't care about early return. So instead of adding and bearing extra logic, I'd just swap 2 lines of existing code.

Problem with the code you had proposed is shown below:

Quoted 1 line

./a.out

i is 1
i is 2
i is 3
i is 4
i is 5
i is 6
i is 7
i is 8
i is 9
i is 10
in done
lisatest ~

Quoted 1 line

cat test3.c

#include<stdio.h>

main() {
        int i = 0, cur, nvec = 10;
        for (cur = 0; cur < 20; cur++) {
                if (i++ == nvec)
                        goto done;
                printf(" i is %d\n", i);
        }

done:
printf("in done\n");
}

So now it is because post increment operator in i++,
For that reason in the posposed code we will hit irqs[nvec], which may cause crash, as size of irqs is nvec.

Now if we preincrement, then we will loop correctly, but nvec == 0 check will not happen.

Like here with preincrement in above code we are not hitting (i == nvec) .

Quoted 1 line

./a.out

i is 1
i is 2
i is 3
i is 4
i is 5
i is 6
i is 7
i is 8
i is 9
in done

So with preincrement if we want the check for nvec == 0, we will need the check with extra if condition before the loop.

#11 lore raw
Quoted 102 lines · Souradeep Chakrabarti
Quoted 48 lines

-----Original Message-----
From: Yury Norov <[email protected]>
Sent: Tuesday, December 12, 2023 10:04 PM
To: Souradeep Chakrabarti <[email protected]>
Cc: KY Srinivasan <[email protected]>; Haiyang Zhang <[email protected]>; [email protected]; Dexuan Cui <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; Long Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; linux- [email protected]; Souradeep Chakrabarti <[email protected]>; Paul Rosswurm <[email protected]>
Subject: [EXTERNAL] Re: [PATCH V5 net-next] net: mana: Assigning IRQ affinity on HT cores

[Some people who received this message don't often get email from [email protected]. Learn why this is important at
https://aka.ms/LearnAboutSenderIdentification ]

Quoted 7 lines
Quoted 7 lines
Quoted 7 lines
Quoted 7 lines

Review

Quoted 7 lines
(quoted diff) +7 -0
+     rcu_read_lock();
+     for_each_numa_hop_mask(next, next_node) {
+             cpumask_andnot(curr, next, prev);
+             for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+                     cpumask_copy(cpus, curr);
+                     for_each_cpu(cpu, cpus) {
+                             irq_set_affinity_and_hint(irqs[i],

topology_sibling_cpumask(cpu));

Quoted 8 lines
Quoted 8 lines
Quoted 8 lines
Quoted 6 lines

Review

Quoted 2 lines
(quoted diff) +2 -0
+                             if (++i == nvec)
+                                     goto done;

Think what if you're passed with irq_setup(NULL, 0, 0). That's why I suggested to place this check at the beginning.

irq_setup() is a helper function for mana_gd_setup_irqs(), which already takes care of no NULL pointer for irqs, and 0 number of interrupts can

not be passed.

Quoted 9 lines
Quoted 9 lines
Quoted 4 lines

nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX); if (nvec < 0)
return nvec;

I know that. But still it's a bug. The common convention is that if a 0-length array is passed to a function, it should not dereference the pointer.

Quoted 6 lines
Quoted 2 lines

I will add one if check in the begining of irq_setup() to verify the pointer and the nvec number.

Yes you can, but what for? This is an error anyways, and you don't care about early return. So instead of adding and bearing extra logic, I'd just swap 2 lines of existing code.

Problem with the code you had proposed is shown below:

Quoted 1 line

./a.out

i is 1
i is 2
i is 3
i is 4
i is 5
i is 6
i is 7
i is 8
i is 9
i is 10
in done
lisatest ~

Quoted 1 line

cat test3.c

#include<stdio.h>

main() {
        int i = 0, cur, nvec = 10;
        for (cur = 0; cur < 20; cur++) {
                if (i++ == nvec)
                        goto done;
                printf(" i is %d\n", i);
        }

done:
printf("in done\n");
}

So now it is because post increment operator in i++,
For that reason in the posposed code we will hit irqs[nvec], which may cause crash, as size of irqs is nvec.

Now if we preincrement, then we will loop correctly, but nvec == 0 check will not happen.

Like here with preincrement in above code we are not hitting (i == nvec) .

Quoted 1 line

./a.out

i is 1
i is 2
i is 3
i is 4
i is 5
i is 6
i is 7
i is 8
i is 9
in done

Quoted 2 lines

So with preincrement if we want the check for nvec == 0, we will need the check with extra if condition before the loop.

OK, I see. Then just separate it:

         for (cur = 0; cur < 20; cur++) {
                 if (i == nvec)
                         goto done;
                 printf(" i is %d\n", i++);
#12 lore raw
In reply to Souradeep Chakrabarti

Hi Souradeep,

Please find inline for couple of comments.

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 6 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +6 -0
+
+	if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+		err = -ENOMEM;
+		return err;
+	}
+	if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {

[Suman] memory leak here, should free 'curr'.

Quoted 45 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +11 -0
+		err = -ENOMEM;
+		return err;
+	}
+
+	rcu_read_lock();
+	for_each_numa_hop_mask(next, next_node) {
+		cpumask_andnot(curr, next, prev);
+		for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+			cpumask_copy(cpus, curr);
+			for_each_cpu(cpu, cpus) {
+				irq_set_affinity_and_hint(irqs[i],

topology_sibling_cpumask(cpu));

drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+				if (++i == nvec)
+					goto done;
+				cpumask_andnot(cpus, cpus,

topology_sibling_cpumask(cpu));

drivers/net/ethernet/microsoft/mana/gdma_main.c +12 -0
+				++cnt;
+			}
+		}
+		prev = next;
+	}
+done:
+	rcu_read_unlock();
+	free_cpumask_var(curr);
+	free_cpumask_var(cpus);
+	return err;
+}
+

static int mana_gd_setup_irqs(struct pci_dev *pdev) {

drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -1
-	unsigned int max_queues_per_port = num_online_cpus();
	struct gdma_context *gc = pci_get_drvdata(pdev);
drivers/net/ethernet/microsoft/mana/gdma_main.c +1 -0
+	unsigned int max_queues_per_port;
	struct gdma_irq_context *gic;
	unsigned int max_irqs, cpu;
drivers/net/ethernet/microsoft/mana/gdma_main.c +2 -1
-	int nvec, irq;
+	int start_irq_index = 1;
+	int nvec, *irqs, irq;
	int err, i = 0, j;
drivers/net/ethernet/microsoft/mana/gdma_main.c +2 -0
+	cpus_read_lock();
+	max_queues_per_port = num_online_cpus();
	if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
		max_queues_per_port = MANA_MAX_NUM_QUEUES;

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev · line 1304

Quoted 3 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev
 *pdev)
 	nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
 	if (nvec < 0)

[Suman] cpus_read_unlock()?

Quoted 83 lines
(quoted diff) +8 -0
 		return nvec;
+	if (nvec <= num_online_cpus())
+		start_irq_index = 0;
+
+	irqs = kmalloc_array((nvec - start_irq_index), sizeof(int),
 GFP_KERNEL);
+	if (!irqs) {
+		err = -ENOMEM;
+		goto free_irq_vector;
+	}
 
	gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
				   GFP_KERNEL);
drivers/net/ethernet/microsoft/mana/gdma_main.c +30 -7
@@ -1287,21 +1336,44 @@ static int mana_gd_setup_irqs(struct pci_dev
 *pdev)
 			goto free_irq;
 		}
 
-		err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-		if (err)
-			goto free_irq;
-
-		cpu = cpumask_local_spread(i, gc->numa_node);
-		irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+		if (!i) {
+			err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+			if (err)
+				goto free_irq;
+
+			/* If number of IRQ is one extra than number of online
 CPUs,
+			 * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+			 * same CPU.
+			 * Else we will use different CPUs for IRQ0 and IRQ1.
+			 * Also we are using cpumask_local_spread instead of
+			 * cpumask_first for the node, because the node can be
+			 * mem only.
+			 */
+			if (start_irq_index) {
+				cpu = cpumask_local_spread(i, gc->numa_node);
+				irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+			} else {
+				irqs[start_irq_index] = irq;
+			}
+		} else {
+			irqs[i - start_irq_index] = irq;
+			err = request_irq(irqs[i - start_irq_index],
 mana_gd_intr, 0,
+					  gic->name, gic);
+			if (err)
+				goto free_irq;
+		}
 	}
 
+	err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+	if (err)
+		goto free_irq;
 	err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
 	if (err)
 		goto free_irq;
 
 	gc->max_num_msix = nvec;
 	gc->num_msix_usable = nvec;
-
+	cpus_read_unlock();
	return 0;

free_irq:

drivers/net/ethernet/microsoft/mana/gdma_main.c +1 -0
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev
 *pdev)
 	}
 
 	kfree(gc->irq_contexts);
+	kfree(irqs);
 	gc->irq_contexts = NULL;

free_irq_vector:

(quoted diff) +1 -0
+	cpus_read_unlock();
	pci_free_irq_vectors(pdev);
	return err;
}

--
2.34.1

#13 lore raw
Quoted 26 lines

-----Original Message-----
From: Suman Ghosh <[email protected]>
Sent: Tuesday, December 12, 2023 11:48 PM
To: Souradeep Chakrabarti <[email protected]>; KY Srinivasan <[email protected]>; Haiyang Zhang <[email protected]>; [email protected]; Dexuan Cui <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; Long Li <[email protected]>; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; [email protected]; linux- [email protected]; [email protected]
Cc: Souradeep Chakrabarti <[email protected]>; Paul Rosswurm <[email protected]>
Subject: [EXTERNAL] RE: [EXT] [PATCH V5 net-next] net: mana: Assigning IRQ affinity on HT cores

[Some people who received this message don't often get email from [email protected]. Learn why this is important at
https://aka.ms/LearnAboutSenderIdentification ]

Hi Souradeep,

Please find inline for couple of comments.

Quoted 7 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c void mana_gd_free_res_map(struct gdma_resource *r) · line 1257

Quoted 6 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +6 -0
+
+      if (!zalloc_cpumask_var(&curr, GFP_KERNEL)) {
+              err = -ENOMEM;
+              return err;
+      }
+      if (!zalloc_cpumask_var(&cpus, GFP_KERNEL)) {

[Suman] memory leak here, should free 'curr'.

This will be taken care in next version.

Quoted 44 lines
Quoted 44 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +11 -0
+              err = -ENOMEM;
+              return err;
+      }
+
+      rcu_read_lock();
+      for_each_numa_hop_mask(next, next_node) {
+              cpumask_andnot(curr, next, prev);
+              for (w = cpumask_weight(curr), cnt = 0; cnt < w; ) {
+                      cpumask_copy(cpus, curr);
+                      for_each_cpu(cpu, cpus) {
+                              irq_set_affinity_and_hint(irqs[i],

topology_sibling_cpumask(cpu));

drivers/net/ethernet/microsoft/mana/gdma_main.c +3 -0
+                              if (++i == nvec)
+                                      goto done;
+                              cpumask_andnot(cpus, cpus,

topology_sibling_cpumask(cpu));

drivers/net/ethernet/microsoft/mana/gdma_main.c +12 -0
+                              ++cnt;
+                      }
+              }
+              prev = next;
+      }
+done:
+      rcu_read_unlock();
+      free_cpumask_var(curr);
+      free_cpumask_var(cpus);
+      return err;
+}
+

static int mana_gd_setup_irqs(struct pci_dev *pdev) {

drivers/net/ethernet/microsoft/mana/gdma_main.c +5 -2
-      unsigned int max_queues_per_port = num_online_cpus();
      struct gdma_context *gc = pci_get_drvdata(pdev);
+      unsigned int max_queues_per_port;
      struct gdma_irq_context *gic;
      unsigned int max_irqs, cpu;
-      int nvec, irq;
+      int start_irq_index = 1;
+      int nvec, *irqs, irq;
      int err, i = 0, j;
 
+      cpus_read_lock();
+      max_queues_per_port = num_online_cpus();
      if (max_queues_per_port > MANA_MAX_NUM_QUEUES)
              max_queues_per_port = MANA_MAX_NUM_QUEUES;
Quoted 5 lines

drivers/net/ethernet/microsoft/mana/gdma_main.c static int mana_gd_setup_irqs(struct pci_dev · line 1304

Quoted 4 lines
drivers/net/ethernet/microsoft/mana/gdma_main.c +0 -0
@@ -1261,6 +1302,14 @@ static int mana_gd_setup_irqs(struct pci_dev
 *pdev)
      nvec = pci_alloc_irq_vectors(pdev, 2, max_irqs, PCI_IRQ_MSIX);
      if (nvec < 0)

[Suman] cpus_read_unlock()?

Thanks for pointing, it will be taken care off in the V6.

Quoted 84 lines
Quoted 84 lines
(quoted diff) +8 -0
              return nvec;
+      if (nvec <= num_online_cpus())
+              start_irq_index = 0;
+
+      irqs = kmalloc_array((nvec - start_irq_index), sizeof(int),
 GFP_KERNEL);
+      if (!irqs) {
+              err = -ENOMEM;
+              goto free_irq_vector;
+      }
 
      gc->irq_contexts = kcalloc(nvec, sizeof(struct gdma_irq_context),
                                 GFP_KERNEL); @@ -1287,21 +1336,44 @@
static int mana_gd_setup_irqs(struct pci_dev
*pdev)
                      goto free_irq;
              }
drivers/net/ethernet/microsoft/mana/gdma_main.c +7 -6
-              err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
-              if (err)
-                      goto free_irq;
-
-              cpu = cpumask_local_spread(i, gc->numa_node);
-              irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+              if (!i) {
+                      err = request_irq(irq, mana_gd_intr, 0, gic->name, gic);
+                      if (err)
+                              goto free_irq;
+
+                      /* If number of IRQ is one extra than number of
+ online

CPUs,

drivers/net/ethernet/microsoft/mana/gdma_main.c +16 -0
+                       * then we need to assign IRQ0 (hwc irq) and IRQ1 to
+                       * same CPU.
+                       * Else we will use different CPUs for IRQ0 and IRQ1.
+                       * Also we are using cpumask_local_spread instead of
+                       * cpumask_first for the node, because the node can be
+                       * mem only.
+                       */
+                      if (start_irq_index) {
+                              cpu = cpumask_local_spread(i, gc->numa_node);
+                              irq_set_affinity_and_hint(irq, cpumask_of(cpu));
+                      } else {
+                              irqs[start_irq_index] = irq;
+                      }
+              } else {
+                      irqs[i - start_irq_index] = irq;
+                      err = request_irq(irqs[i - start_irq_index],

mana_gd_intr, 0,

drivers/net/ethernet/microsoft/mana/gdma_main.c +8 -1
+                                        gic->name, gic);
+                      if (err)
+                              goto free_irq;
+              }
      }
 
+      err = irq_setup(irqs, (nvec - start_irq_index), gc->numa_node);
+      if (err)
+              goto free_irq;
      err = mana_gd_alloc_res_map(nvec, &gc->msix_resource);
      if (err)
              goto free_irq;
 
      gc->max_num_msix = nvec;
      gc->num_msix_usable = nvec;
-
+      cpus_read_unlock();
      return 0;

free_irq:

drivers/net/ethernet/microsoft/mana/gdma_main.c +1 -0
@@ -1314,8 +1386,10 @@ static int mana_gd_setup_irqs(struct pci_dev
 *pdev)
      }
 
      kfree(gc->irq_contexts);
+      kfree(irqs);
      gc->irq_contexts = NULL;

free_irq_vector:

+      cpus_read_unlock();
      pci_free_irq_vectors(pdev);
      return err;
}

--
2.34.1