Software RAID-0 striping over Hardware RAID-5
A message that is not in the archive (sent off-list or not yet received): [email protected]
On Mon, 20 Sep 2004 at 9:49am, [email protected] wrote
Quoted 4 lines
Have you ever tested your systems while one of your RAID5 arrays is rebuilding or verifying? (I'm about to do that right now). I'm wondering if Linux Software RAID-0 might falter if one of the two arrays is significantly slower than the other (while rebuilding)?
I've had arrays under normal (sporadically heavy) usage during a rebuild, and there wasn't a problem.
Quoted 7 lines
My inclination is to not use a hot spare. Instead, I rely on 3ware's email notification feature to alert me that a drive needs to be replaced. I always keep a spare handy that can be popped into place immediately. Also, I want to have control over when rebuilding takes place. It would be a bad thing to rebuild during certain critical high I/O moments of the day -- whereas rebuilding at night would be much less stressful on the system. Do you see anything wrong with this approach?
Yes -- it requires you to be on call 24x7 for maximum protection. And even then the level of protection is less than with a hot spare, given that it will take you time to get from whereever you are to whereever the server is. Also, disks can sometimes have a tendency to go in quick succession. I would *strongly* recommend a hot spare.
Remember, you're cutting your reliability in half by striping the two arrays. Why not maximally protect those individual arrays?
Signature · 3 lines
Joshua Baker-LePain Department of Biomedical Engineering Duke University