paride error, aparantly with VFS
I appear to have found a problem reading from paride hard disks under 2.4.2
Reading from the raw block devices seems to be fine.
# dd if=/dev/pd/disc0/disc of=/dev/null works.
However, accessing partitions on the device through VFS by mounting them hangs the machine.
With vfat and msdos partitions:
# mount -t (vfat|msdos) /dev/pd/disc0/part1 /mnt and then # cat /mnt/* > /dev/null or # dd if=/mnt/drvspace.000 of=/dev/null
I eventually see the following error message, and all logins are unresponsive. I can reboot with SysRq.
do_pd_read_drq: status = 0x10050 = SEEK READY TMO
Doing a similar test with an ext2 fs on the drive:
do_pd_read_drq: status = 0x10052 = SEEK READY TMO
Changing parallel port mode in the BIOS does not make any difference.
The paride controller is a Shuttle EPAT plus. The parallel port is an Intel 82371AB (I think)
-- Ferret
Quoted 1 line · On Sun, Mar 25, 2001 at 09:37:38PM -0800, [email protected] wrote:
do_pd_read_drq: status =0x10050= SEEK READY TMO
Please try a recent -ac kernel and let me know if the problem persists or goes away.
Tim.
*/
Quoted 6 lines · Tim Waugh
Quoted 1 line · On Sun, Mar 25, 2001 at 09:37:38PM -0800, [email protected] wrote:
do_pd_read_drq: status =0x10050= SEEK READY TMOPlease try a recent -ac kernel and let me know if the problem persists or goes away.
ac25 appears to have this problem fixed.
Still got bit by the OOPS problem in my other post when I tried to switch drives in the box, though.
-- Ferret