Egress shaping over multiple interfaces?
Hello Hasso,
Thursday, October 31, 2002, 10:45:05 PM, you wrote:
HT> IMQ? I'm using it in the production. 100 IMQ devices 10 - 50 of them HT> in use. Number of devices in use is changing in boxes and I had to HT> create just enough IMQ devices. I'm using IMQ in combination with TBF HT> to get bidirectional shaping. No problems at all.
As I know max number of imq devices 16
i.e.
modprobe imq numdevs=16
Do you change this line in inclue/linux/imq.h
#define IMQ_MAX_DEVS 16
-----------------------------------
mailto:[email protected]
BR
Alexey Talikov
FORTEK
-----------------------------------
Quoted 10 lines · Alexey Talikov
Hello Hasso,
Quoted 5 lines · you
IMQ? I'm using it in the production. 100 IMQ devices 10 - 50 of them in use. Number of devices in use is changing in boxes and I had to create just enough IMQ devices. I'm using IMQ in combination with TBF to get bidirectional shaping. No problems at all.
Quoted 6 lines
As I know max number of imq devices 16
i.e.
modprobe imq numdevs=16
Do you change this line ininclue/linux/imq.h#define
IMQ_MAX_DEVS16
Yes. AFAIK it can be max 127. There is still bug somewhere else though. modprobe imq numdevs=X fails when X>100 so you can use only devices 0-99. It was enough for me and I didn't have time to investigate.
Signature · 1 line
Hasso