Skip to contentSkip to conversation

Network problems with b44 in 2.6.0

DISCUSSION Michael Guntsche 1 participant 1 message Dec 29, 2003

lore
Share & tools
lore
#0 lore raw

Recently I activated my BCM4401 network card on my notebook, using the b44 module, to do some large file transfers (normally I use my wireless connection).
While copying around several MB between 2 computers I noticed something very strange.

Scp'ing a file FROM the notebook TO my gateway, I got a throughput of 1.2MB. This looks normal, since the gateway is a very old machine.

--------

The problems started when copying a file in the opposite direction (FROM the gateway TO the notebook).

As soon as I started the process, the following error messages started appearing in my syslog.

b44: eth0: Link is down.
b44: eth0: Link is up at 100 Mbps, full duplex.
b44: eth0: Flow control is on for TX and on for RX.
b44: eth0: Link is down.
b44: eth0: Link is up at 100 Mbps, full duplex.
b44: eth0: Flow control is on for TX and on for RX.
b44: eth0: Link is down.
b44: eth0: Link is up at 100 Mbps, full duplex.
b44: eth0: Flow control is on for TX and on for RX.
b44: eth0: Link is down.

After a few seconds the whole transfer -stalled--.
The Link just went down and up and the messages filled my syslog. For me it looks like that something is seriously wrong on the RX side, since sending a file works without a problem.

System Info:
Acer TravelMate 800
Debian unstable
Kernel 2.6.0 no modifications
Broadcom Corporation BCM4401 100Base-T (rev 01)

Please CC: me if you have hints/need more information since I am not subscribed to the list

Thanks in advance,
Michael