Failed RAID-5 with 4 disks
Hi,
I have a RAID-5 set up with the following raidtab:
raiddev /dev/md0
raid-level 5
nr-raid-disks 4
nr-spare-disks 0
persistent-superblock 1
parity-algorithm left-symmetric
chunk-size 256
device /dev/hde
raid-disk 0
device /dev/hdg
raid-disk 1
device /dev/hdi
raid-disk 2
device /dev/hdk
raid-disk 3My hde has failed some time ago, leaving some
hde: dma_intr: status=0x51 { DriveReady SeekComplete Error }
hde: dma_intr: error=0x84 { DriveStatusError BadCRC }messages in the syslog.
I wanted to get sure it really was damaged, so I did a badblocks (read-only) scan on /dev/hde. It actually found a bad sector on the disk.
I wanted to take the disk out to get me a new one, but unfortunately my hdg seems to have run into trouble too, now. I also have some SeekComplete/BadCRC errors in my log for that disk, too.
Furthermore, i got this:
Jul 25 10:35:49 blackbox kernel: ide: failed opcode was: unknown Jul 25 10:35:49 blackbox kernel: hdg: DMA disabled Jul 25 10:35:49 blackbox kernel: PDC202XX: Secondary channel reset. Jul 25 10:35:49 blackbox kernel: PDC202XX: Primary channel reset. Jul 25 10:35:49 blackbox kernel: hde: lost interrupt Jul 25 10:35:49 blackbox kernel: ide3: reset: master: error (0x00?) Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 488396928 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368976 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368984 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368992 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369000 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369008 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369016 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369024 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369032 Jul 25 10:35:49 blackbox kernel: md: write_disk_sb failed for device hdg Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: disk 2, o:0, dev:hdg Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0
Well, now it seems I have to failed disks in my RAID-5, which of course would be fatal. I am still hoping to somehow rescue the data on the array somehow, but I am not sure what would be the best approach. I don't want to cause any more damage.
When booting my system with all four disks connected, hde and hdg as expected won't get added:
Jul 26 18:07:59 blackbox kernel: md: hdg has invalid sb, not importing! Jul 26 18:07:59 blackbox kernel: md: autorun ... Jul 26 18:07:59 blackbox kernel: md: considering hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdk ... Jul 26 18:07:59 blackbox kernel: md: adding hde ... Jul 26 18:07:59 blackbox kernel: md: created md0 Jul 26 18:07:59 blackbox kernel: md: bind<hde> Jul 26 18:07:59 blackbox kernel: md: bind<hdk> Jul 26 18:07:59 blackbox kernel: md: bind<hdi> Jul 26 18:07:59 blackbox kernel: md: running: <hdi><hdk><hde> Jul 26 18:07:59 blackbox kernel: md: kicking non-fresh hde from array! Jul 26 18:07:59 blackbox kernel: md: unbind<hde> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hde) Jul 26 18:07:59 blackbox kernel: raid5: device hdi operational as raid disk 1 Jul 26 18:07:59 blackbox kernel: raid5: device hdk operational as raid disk 0 Jul 26 18:07:59 blackbox kernel: RAID5 conf printout: Jul 26 18:07:59 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 26 18:07:59 blackbox kernel: disk 0, o:1, dev:hdk Jul 26 18:07:59 blackbox kernel: disk 1, o:1, dev:hdi Jul 26 18:07:59 blackbox kernel: md: do_md_run() returned -22 Jul 26 18:07:59 blackbox kernel: md: md0 stopped. Jul 26 18:07:59 blackbox kernel: md: unbind<hdi> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdi) Jul 26 18:07:59 blackbox kernel: md: unbind<hdk> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdk) Jul 26 18:07:59 blackbox kernel: md: ... autorun DONE.
So hde is not fresh (it has been removed from the array for quite some time now) and hdg has an invalid superblock.
Any advice on what I should do now? Should I better try to rebuild the array with hde or with hdg?
Greetings,
Frank
My suggestion would be to buy two new drives, and DD (or dd rescue) the two bad drives onto the new drives, and then plug the new drive that has the most recent failure on it (HDG?) in, and try running a forced assemble including the HDG drive, then, in readonly mode, run an fsck to check the file system, and see if it thinks most things are okay. *IF* it checks out okay (for the most part.. you will probably lose some data), then plug the second new disk in, and add it to the array as a spare, and it would then start a resync of the array. Otherwise, if the fsck found that the entire filesystem was fubar... then I would try the above steps, but force the assemble with the original failed disk.. but depending on how long in between the two failures its been, and if any data was written to the array after the first failure, this is probably not going to be a good thing.. but could still be useful if you were trying to recover specific files that were not touched in between the two failures.
I would also suggest googling raid manual recovery procedures, some info is outdated, but some of it describes what I just described above.
Tyler.
Quoted 118 lines · Frank Blendinger
Hi,
I have a RAID-5 set up with the following raidtab:
raiddev
/dev/md0raid-level 5 nr-raid-disks 4 nr-spare-disks 0 persistent-superblock 1 parity-algorithm left-symmetric chunk-size 256 device /dev/hde raid-disk 0 device /dev/hdg raid-disk 1 device /dev/hdi raid-disk 2 device /dev/hdk raid-disk 3My hde has failed some time ago, leaving some
hde: dma_intr: status=0x51 { DriveReady SeekComplete Error } hde: dma_intr: error=0x84 { DriveStatusError BadCRC }messages in the syslog.
I wanted to get sure it really was damaged, so I did a badblocks (read-only) scan on
/dev/hde. It actually found a bad sector on the disk.I wanted to take the disk out to get me a new one, but unfortunately my hdg seems to have run into trouble too, now. I also have some SeekComplete/BadCRC errors in my log for that disk, too.
Furthermore, i got this:
Jul 25 10:35:49 blackbox kernel: ide: failed opcode was: unknown Jul 25 10:35:49 blackbox kernel: hdg: DMA disabled Jul 25 10:35:49 blackbox kernel: PDC202XX: Secondary channel reset. Jul 25 10:35:49 blackbox kernel: PDC202XX: Primary channel reset. Jul 25 10:35:49 blackbox kernel: hde: lost interrupt Jul 25 10:35:49 blackbox kernel: ide3: reset: master: error (0x00?) Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 488396928 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368976 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368984 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368992 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369000 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369008 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369016 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369024 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369032 Jul 25 10:35:49 blackbox kernel: md: write_disk_sb failed for device hdg Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: disk 2, o:0, dev:hdg Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0Well, now it seems I have to failed disks in my RAID-5, which of course would be fatal. I am still hoping to somehow rescue the data on the array somehow, but I am not sure what would be the best approach. I don't want to cause any more damage.
When booting my system with all four disks connected, hde and hdg as expected won't get added:
Jul 26 18:07:59 blackbox kernel: md: hdg has invalid sb, not importing! Jul 26 18:07:59 blackbox kernel: md: autorun ... Jul 26 18:07:59 blackbox kernel: md: considering hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdk ... Jul 26 18:07:59 blackbox kernel: md: adding hde ... Jul 26 18:07:59 blackbox kernel: md: created md0 Jul 26 18:07:59 blackbox kernel: md: bind<hde> Jul 26 18:07:59 blackbox kernel: md: bind<hdk> Jul 26 18:07:59 blackbox kernel: md: bind<hdi> Jul 26 18:07:59 blackbox kernel: md: running: <hdi><hdk><hde> Jul 26 18:07:59 blackbox kernel: md: kicking non-fresh hde from array! Jul 26 18:07:59 blackbox kernel: md: unbind<hde> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hde) Jul 26 18:07:59 blackbox kernel: raid5: device hdi operational as raid disk 1 Jul 26 18:07:59 blackbox kernel: raid5: device hdk operational as raid disk 0 Jul 26 18:07:59 blackbox kernel: RAID5 conf printout: Jul 26 18:07:59 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 26 18:07:59 blackbox kernel: disk 0, o:1, dev:hdk Jul 26 18:07:59 blackbox kernel: disk 1, o:1, dev:hdi Jul 26 18:07:59 blackbox kernel: md: do_md_run() returned -22 Jul 26 18:07:59 blackbox kernel: md: md0 stopped. Jul 26 18:07:59 blackbox kernel: md: unbind<hdi> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdi) Jul 26 18:07:59 blackbox kernel: md: unbind<hdk> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdk) Jul 26 18:07:59 blackbox kernel: md: ... autorun DONE.So hde is not fresh (it has been removed from the array for quite some time now) and hdg has an invalid superblock.
Any advice on what I should do now? Should I better try to rebuild the array with hde or with hdg?
Greetings,
Frank
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
It seems theoretically possible, but might take some semi-substantial coding effort, to build a program that would sort of combine fsck and RAID information to get back as much as is feasible.
For example, this program might track down all the inodes it can, and perhaps even hunt for inode magic numbers to augment the inode list (using fuzzy logic - if the inode points to a reasonable series of blocks, for example, and has a possible file length and the files are owned by an existing user - each of these strengthens the program's believe that it has heuristically found a real inode), and then look down the block pointers in the inodes for blocks that are known still good, and ignoring the ones that aren't.
I suppose then you'd need some sort of table, built out of lots of range arithmetic, indicating that N files were 100% recovered, and M files were recovered only in ranges such and so.
Might actually be kind of a fun project once you get really immersed into it.
HTH. :)
Quoted 146 lines · Tyler
My suggestion would be to buy two new drives, and DD (or dd rescue) the two bad drives onto the new drives, and then plug the new drive that has the most recent failure on it (HDG?) in, and try running a forced assemble including the HDG drive, then, in readonly mode, run an fsck to check the file system, and see if it thinks most things are okay. *IF* it checks out okay (for the most part.. you will probably lose some data), then plug the second new disk in, and add it to the array as a spare, and it would then start a resync of the array. Otherwise, if the fsck found that the entire filesystem was fubar... then I would try the above steps, but force the assemble with the original failed disk.. but depending on how long in between the two failures its been, and if any data was written to the array after the first failure, this is probably not going to be a good thing.. but could still be useful if you were trying to recover specific files that were not touched in between the two failures.
I would also suggest googling raid manual recovery procedures, some info is outdated, but some of it describes what I just described above.
Tyler.
Quoted 109 lines · Frank Blendinger
Hi,
I have a RAID-5 set up with the following raidtab:
raiddev
/dev/md0raid-level 5 nr-raid-disks 4 nr-spare-disks 0 persistent-superblock 1 parity-algorithm left-symmetric chunk-size 256 device /dev/hde raid-disk 0 device /dev/hdg raid-disk 1 device /dev/hdi raid-disk 2 device /dev/hdk raid-disk 3My hde has failed some time ago, leaving some
hde: dma_intr: status=0x51 { DriveReady SeekComplete Error } hde: dma_intr: error=0x84 { DriveStatusError BadCRC }messages in the syslog.
I wanted to get sure it really was damaged, so I did a badblocks (read-only) scan on
/dev/hde. It actually found a bad sector on the disk.I wanted to take the disk out to get me a new one, but unfortunately my hdg seems to have run into trouble too, now. I also have some SeekComplete/BadCRC errors in my log for that disk, too.
Furthermore, i got this:
Jul 25 10:35:49 blackbox kernel: ide: failed opcode was: unknown Jul 25 10:35:49 blackbox kernel: hdg: DMA disabled Jul 25 10:35:49 blackbox kernel: PDC202XX: Secondary channel reset. Jul 25 10:35:49 blackbox kernel: PDC202XX: Primary channel reset. Jul 25 10:35:49 blackbox kernel: hde: lost interrupt Jul 25 10:35:49 blackbox kernel: ide3: reset: master: error (0x00?) Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 488396928 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368976 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368984 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368992 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369000 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369008 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369016 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369024 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369032 Jul 25 10:35:49 blackbox kernel: md: write_disk_sb failed for device hdg Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: disk 2, o:0, dev:hdg Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0Well, now it seems I have to failed disks in my RAID-5, which of course would be fatal. I am still hoping to somehow rescue the data on the array somehow, but I am not sure what would be the best approach. I don't want to cause any more damage.
When booting my system with all four disks connected, hde and hdg as expected won't get added:
Jul 26 18:07:59 blackbox kernel: md: hdg has invalid sb, not importing! Jul 26 18:07:59 blackbox kernel: md: autorun ... Jul 26 18:07:59 blackbox kernel: md: considering hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdk ... Jul 26 18:07:59 blackbox kernel: md: adding hde ... Jul 26 18:07:59 blackbox kernel: md: created md0 Jul 26 18:07:59 blackbox kernel: md: bind<hde> Jul 26 18:07:59 blackbox kernel: md: bind<hdk> Jul 26 18:07:59 blackbox kernel: md: bind<hdi> Jul 26 18:07:59 blackbox kernel: md: running: <hdi><hdk><hde> Jul 26 18:07:59 blackbox kernel: md: kicking non-fresh hde from array! Jul 26 18:07:59 blackbox kernel: md: unbind<hde> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hde) Jul 26 18:07:59 blackbox kernel: raid5: device hdi operational as raid disk 1 Jul 26 18:07:59 blackbox kernel: raid5: device hdk operational as raid disk 0 Jul 26 18:07:59 blackbox kernel: RAID5 conf printout: Jul 26 18:07:59 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 26 18:07:59 blackbox kernel: disk 0, o:1, dev:hdk Jul 26 18:07:59 blackbox kernel: disk 1, o:1, dev:hdi Jul 26 18:07:59 blackbox kernel: md: do_md_run() returned -22 Jul 26 18:07:59 blackbox kernel: md: md0 stopped. Jul 26 18:07:59 blackbox kernel: md: unbind<hdi> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdi) Jul 26 18:07:59 blackbox kernel: md: unbind<hdk> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdk) Jul 26 18:07:59 blackbox kernel: md: ... autorun DONE.So hde is not fresh (it has been removed from the array for quite some time now) and hdg has an invalid superblock.
Any advice on what I should do now? Should I better try to rebuild the array with hde or with hdg?
Quoted 9 lines
Greetings,
Frank
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
I had a typo in my original email, near the end, where I say "was fubar... then I would try the above steps, but force the assemble with the original failed disk", I actually meant to say "but force the assemble with the newly DD'd copy of the original/first drive that failed."
Tyler.
Quoted 130 lines · Tyler
My suggestion would be to buy two new drives, and DD (or dd rescue) the two bad drives onto the new drives, and then plug the new drive that has the most recent failure on it (HDG?) in, and try running a forced assemble including the HDG drive, then, in readonly mode, run an fsck to check the file system, and see if it thinks most things are okay. *IF* it checks out okay (for the most part.. you will probably lose some data), then plug the second new disk in, and add it to the array as a spare, and it would then start a resync of the array. Otherwise, if the fsck found that the entire filesystem was fubar... then I would try the above steps, but force the assemble with the original failed disk.. but depending on how long in between the two failures its been, and if any data was written to the array after the first failure, this is probably not going to be a good thing.. but could still be useful if you were trying to recover specific files that were not touched in between the two failures.
I would also suggest googling raid manual recovery procedures, some info is outdated, but some of it describes what I just described above.
Tyler.
Quoted 108 lines · Frank Blendinger
Hi,
I have a RAID-5 set up with the following raidtab:
raiddev
/dev/md0raid-level 5 nr-raid-disks 4 nr-spare-disks 0 persistent-superblock 1 parity-algorithm left-symmetric chunk-size 256 device /dev/hde raid-disk 0 device /dev/hdg raid-disk 1 device /dev/hdi raid-disk 2 device /dev/hdk raid-disk 3My hde has failed some time ago, leaving some hde:
dma_intr: status=0x51 { DriveReady SeekComplete Error }hde: dma_intr: error=0x84 { DriveStatusError BadCRC }messages in the syslog.
I wanted to get sure it really was damaged, so I did a badblocks (read-only) scan on
/dev/hde. It actually found a bad sector on the disk.I wanted to take the disk out to get me a new one, but unfortunately my hdg seems to have run into trouble too, now. I also have some SeekComplete/BadCRC errors in my log for that disk, too.
Furthermore, i got this:
Jul 25 10:35:49 blackbox kernel: ide: failed opcode was: unknown Jul 25 10:35:49 blackbox kernel: hdg: DMA disabled Jul 25 10:35:49 blackbox kernel: PDC202XX: Secondary channel reset. Jul 25 10:35:49 blackbox kernel: PDC202XX: Primary channel reset. Jul 25 10:35:49 blackbox kernel: hde: lost interrupt Jul 25 10:35:49 blackbox kernel: ide3: reset: master: error (0x00?) Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 488396928 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368976 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368984 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159368992 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369000 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369008 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369016 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369024 Jul 25 10:35:49 blackbox kernel: end_request: I/O error, dev hdg, sector 159369032 Jul 25 10:35:49 blackbox kernel: md: write_disk_sb failed for device hdg Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0 Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: disk 2, o:0, dev:hdg Jul 25 10:35:49 blackbox kernel: RAID5 conf printout: Jul 25 10:35:49 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 25 10:35:49 blackbox kernel: disk 0, o:1, dev:hdk Jul 25 10:35:49 blackbox kernel: disk 1, o:1, dev:hdi Jul 25 10:35:49 blackbox kernel: lost page write due to I/O error on md0Well, now it seems I have to failed disks in my RAID-5, which of course would be fatal. I am still hoping to somehow rescue the data on the array somehow, but I am not sure what would be the best approach. I don't want to cause any more damage.
When booting my system with all four disks connected, hde and hdg as expected won't get added:
Jul 26 18:07:59 blackbox kernel: md: hdg has invalid sb, not importing! Jul 26 18:07:59 blackbox kernel: md: autorun ... Jul 26 18:07:59 blackbox kernel: md: considering hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdi ... Jul 26 18:07:59 blackbox kernel: md: adding hdk ... Jul 26 18:07:59 blackbox kernel: md: adding hde ... Jul 26 18:07:59 blackbox kernel: md: created md0 Jul 26 18:07:59 blackbox kernel: md: bind<hde> Jul 26 18:07:59 blackbox kernel: md: bind<hdk> Jul 26 18:07:59 blackbox kernel: md: bind<hdi> Jul 26 18:07:59 blackbox kernel: md: running: <hdi><hdk><hde> Jul 26 18:07:59 blackbox kernel: md: kicking non-fresh hde from array! Jul 26 18:07:59 blackbox kernel: md: unbind<hde> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hde) Jul 26 18:07:59 blackbox kernel: raid5: device hdi operational as raid disk 1 Jul 26 18:07:59 blackbox kernel: raid5: device hdk operational as raid disk 0 Jul 26 18:07:59 blackbox kernel: RAID5 conf printout: Jul 26 18:07:59 blackbox kernel: --- rd:4 wd:2 fd:2 Jul 26 18:07:59 blackbox kernel: disk 0, o:1, dev:hdk Jul 26 18:07:59 blackbox kernel: disk 1, o:1, dev:hdi Jul 26 18:07:59 blackbox kernel: md: do_md_run() returned -22 Jul 26 18:07:59 blackbox kernel: md: md0 stopped. Jul 26 18:07:59 blackbox kernel: md: unbind<hdi> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdi) Jul 26 18:07:59 blackbox kernel: md: unbind<hdk> Jul 26 18:07:59 blackbox kernel: md: export_rdev(hdk) Jul 26 18:07:59 blackbox kernel: md: ... autorun DONE.So hde is not fresh (it has been removed from the array for quite some time now) and hdg has an invalid superblock.
Any advice on what I should do now? Should I better try to rebuild the array with hde or with hdg?
Quoted 9 lines
Greetings,
Frank
-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html-
To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to [email protected]
More majordomo info at http://vger.kernel.org/majordomo-info.html
Quoted 7 lines · Tyler
My suggestion would be to buy two new drives, and DD (or dd rescue) the two bad drives onto the new drives, and then plug the new drive that has the most recent failure on it (HDG?) in, and try running a forced assemble including the HDG drive, then, in readonly mode, run an fsck to check the file system, and see if it thinks most things are okay. *IF* it checks out okay (for the most part.. you will probably lose some data), then plug the second new disk in, and add it to the array as a
Quoted 8 lines
spare, and it would then start a resync of the array. Otherwise, if the fsck found that the entire filesystem was fubar... then I would try the above steps, but force the assemble with the original failed disk.. but depending on how long in between the two failures its been, and if any data was written to the array after the first failure, this is probably not going to be a good thing.. but could still be useful if you were trying to recover specific files that were not touched in between the two failures.
Thanks for your suggestions.
This is what I did so far: I got one of the two bad drives (the one that failed first) replaced with a new one. I copied the other bad drive to the new one with dd. I guess that not everything could be copied alright, I got 10 "Buffer I/O error on device hdg, logical sector ..." and about 35 "end_request: I/O error, hdg, sector ..." error messages in my syslog.
Now I'm stuck re-activating the array with the dd'ed hde and the working hdi and hdk. I tried "mdadm --assemble --scan /dev/md0", which told me "mdadm: /dev/md0 assembled from 2 drives - not enough to start the array."
I then tried hot-adding hde with "mdadm --add /dev/hde [--force] /dev/md0" but that only got me "mdadm: /dev/hde does not appear to be an md device".
Any suggestions?
Greets,
Frank
Quoted 8 lines · Mike Hardy
Quoted 7 lines · Frank Blendinger
This is what I did so far: I got one of the two bad drives (the one that failed first) replaced with a new one. I copied the other bad drive to the new one with dd. I guess that not everything could be copied alright, I got 10 "Buffer I/O error on device hdg, logical sector ..." and about 35 "
end_request: I/O error, hdg, sector ..." error messages in my syslog.
Quoted 7 lines
Quoted 3 lines
Now I'm stuck re-activating the array with the dd'ed hde and the working hdi and hdk. I tried "mdadm --assemble --scan
/dev/md0", which told me "mdadm:/dev/md0assembled from 2 drives - not enough to start the array."Does an mdadm -E on the dd'd
/dev/hdeshow that it has the superblock and knows about the array? That would confirm that it has the data and is ready to go.
mdadm -E /dev/hde tells me:
mdadm: No super block found on /dev/hde (Expected magic a92b4efc, got 00000000)
Quoted 8 lines
Given that, you want to do a version of the create/assemble that forcibly uses all three drives, even though one of them is out of date from the raid set's perspective.
I believe its possible to issue a create line that has a 'missing' entry for the drive missing, but order is important. Luckily since one drive is missing, md won't resync or anything so you should get multiple tries.
Quoted 6 lines
Something like 'mdadm --create --force -level 5 -n 4
/dev/md0/dev/hda/dev/hdb/dev/hdemissing' is what you're looking for.Obviously I don't know what your disk names are, so put the correct ones in there, not the ones I used. If you don't get a valid raid set from that, you could try moving the order around.
OK, sounds good. I tried this:
$ mdadm --create --force --level 5 -n 4 /dev/md0 /dev/hdi /dev/hdk /dev/hde missing mdadm: /dev/hdi appears to be part of a raid array: level=5 devices=4 ctime=Mon Apr 18 21:05:23 2005 mdadm: /dev/hdk appears to contain an ext2fs file system size=732595200K mtime=Sun Jul 24 03:08:46 2005 mdadm: /dev/hdk appears to be part of a raid array: level=5 devices=4 ctime=Mon Apr 18 21:05:23 2005 Continue creating array?
I'm not quite sure about the output, hdk gets listed twice (once false as an ext2) and hde (this is the dd'ed disk) not at all. Should i continue here?
Quoted 9 lines
Each time you do that, you'll be creating a brand new raid set with new superblocks, but the layout will hopefully match, and it won't update the data because a drive is missing. After the raid is created the right way, you should find your data.
Then you can hot-add a new drive to the array, to get your redundancy back. I'd definitely use smartctl -t long on
/dev/hdgto find the blocks that are bad, and use the BadBlockHowTo (google for that) so you can clear the bad blocks.
Of course I don't want the second broken hard drive as spare. I just used it to dd its content to the new disk. I am going to get a new drive for the second failed one once I got the array back up and running (without redundancy).
Should a check for bad blocks on hdg and then repeat the dd to the new disk?
Quoted 3 lines
Alternatively you could forcibly assemble the array as it was with Neil's new faulty-read-correction patch, and the blocks will probably get auto-cleared.
I am still using mdadm 1.9.0 (the package that came with Debian sarge). Would you suggest me to manually upgrade to a 2.0 version?
Quoted 9 lines
Quoted 3 lines
I then tried hot-adding hde with "mdadm --add
/dev/hde[--force]/dev/md0" but that only got me "mdadm:/dev/hdedoes not appear to be an md device".You got the array and the drive in the wrong positions here, thus the error message, and you can't hot-add to an array that isn't started. hot-add is to add redundancy to an array that is already running - for instance after a drive has failed you hot-remove it, then after you've cleared bad blocks, you hot-add it.
I see, I completely misunderstood the manpage there.
Greets,
Frank
Quoted 10 lines · Frank Blendinger
Quoted 3 lines · Mike Hardy
Does an mdadm -E on the dd'd
/dev/hdeshow that it has the superblock and knows about the array? That would confirm that it has the data and is ready to go.mdadm -E
/dev/hdetells me:
mdadm: No super block found on/dev/hde(Expected magica92b4efc, got 00000000)
This is bad - it appears that your dd either did not work or was not complete or something, but /dev/hde does not contain a copy of an array component.
You can not continue until you've got one of the two failed disks' data.
Quoted 11 lines
OK, sounds good. I tried this:
$ mdadm --create --force --level 5 -n 4 /dev/md0 /dev/hdi /dev/hdk /dev/hde missing mdadm: /dev/hdi appears to be part of a raid array: level=5 devices=4 ctime=Mon Apr 18 21:05:23 2005 mdadm: /dev/hdk appears to contain an ext2fs file system size=732595200K mtime=Sun Jul 24 03:08:46 2005 mdadm: /dev/hdk appears to be part of a raid array: level=5 devices=4 ctime=Mon Apr 18 21:05:23 2005 Continue creating array?
Quoted 3 lines
I'm not quite sure about the output, hdk gets listed twice (once false as an ext2) and hde (this is the dd'ed disk) not at all. Should i continue here?
Not sure why hdk gets listed twice, but its probably not a huge deal. The missing hde is the big problem though. You don't have enough components together yet
Quoted 4 lines
Of course I don't want the second broken hard drive as spare. I just used it to dd its content to the new disk. I am going to get a new drive for the second failed one once I got the array back up and running (without redundancy).
The 'missing' slot and '-n 4' tells mdadm that you are creating a 4 disk array, but one of the slots is empty at this point. The array will created and initially run in degraded mode. When you add a disk to the array later, it won't be a spare, it will give you the normal redundancy.
Quoted 2 lines
Should a check for bad blocks on hdg and then repeat the dd to the new disk?
I'm not going to comment on specific disks, I don't really know your complete situation. The process is the point though. If you have a disk that failed, for any reason, you should run a long SMART test on it ('smartctl -t long <disk>'). If it has bad blocks, you should fix them. If it has data on it that is not redundant you should try to copy it elsewhere first. Once the disks pass the long SMART test, they're capable of being used without problems in a raid array.
Quoted 7 lines
Quoted 3 lines
Alternatively you could forcibly assemble the array as it was with Neil's new faulty-read-correction patch, and the blocks will probably get auto-cleared.
I am still using mdadm 1.9.0 (the package that came with Debian sarge). Would you suggest me to manually upgrade to a 2.0 version?
I'd get your data back first. Its clear you haven't used the tools much, so I wouldn't throw an attempt at upgrading them into the mix. Getting the data back is hard enough, even if the tools are old hat.
Quoted 1 line
I see, I completely misunderstood the manpage there.
Given this, and your questions about how to add the drives, and the redundancy etc., the main thing I'd recommend is to practice this stuff in a safe environment. If your data is important, and you plan on running a raid for a while, it will really pay off in the long run, and its so much more relaxing to run this stuff when you're confident in the tools you have to use when problems crop up.
How to do that? I'd use loop devices. You create a number of files of the same size, you export them as loopback-mounted devices, and build a raid out of them. Open a second terminal so you can watch cat /proc/mdstat. Open a third so you can tail -f /var/log/messages, then start playing around with creating new arrays out of the loop files, hot-removing, hot-adding etc. All in a safe way.
I wrote a script that facilitates this a while back and posted it to the
list: http://www.spinics.net/lists/raid/msg07564.html
You should be able to simulate what you need to do with your real disks by setting up 4 loop devices and failing two, then attempting to recover.
-Mike
Am Freitag, 16. September 2005 21:09 schrieb Frank Blendinger:
Quoted 9 lines · Mike Hardy
Quoted 8 lines
Quoted 7 lines · Frank Blendinger
This is what I did so far: I got one of the two bad drives (the one that failed first) replaced with a new one. I copied the other bad drive to the new one with dd. I guess that not everything could be copied alright, I got 10 "Buffer I/O error on device hdg, logical sector ..." and about 35 "
end_request: I/O error, hdg, sector ..." error messages in my syslog.
I am unable to find the beginning of this thread, so please excuse me if this has already been said, but:
You did use ddrescue, didn't you? Because dd, when it fails to read a block, it won't write that block. That's why your superblock might have "moved" about 45 sectors towards the beginning of the drive. ddrescue writes a block with zeros when reading that block fails, so every readable sector get copdied to its corresponding sector on the new drive..
Burkhard
Quoted 13 lines · Burkhard Carstens
Am Freitag, 16. September 2005 21:09 schrieb Frank Blendinger:
Quoted 9 lines · Mike Hardy
Quoted 8 lines
Quoted 7 lines · Frank Blendinger
This is what I did so far: I got one of the two bad drives (the one that failed first) replaced with a new one. I copied the other bad drive to the new one with dd. I guess that not everything could be copied alright, I got 10 "Buffer I/O error on device hdg, logical sector ..." and about 35 "
end_request: I/O error, hdg, sector ..." error messages in my syslog.I am unable to find the beginning of this thread, so please excuse me if this has already been said, but:
Quoted 6 lines
You did use ddrescue, didn't you? Because dd, when it fails to read a block, it won't write that block. That's why your superblock might have "moved" about 45 sectors towards the beginning of the drive. ddrescue writes a block with zeros when reading that block fails, so every readable sector get copdied to its corresponding sector on the new drive..
OK, thanks for the note, I am going to do a bad block scan with smart and then try again with ddrescue. I hope this will restore the superblock.
Greets,
Frank