#0 lore raw

I reported a bug in envy24control about the text displayed when using the BNC word clock input on a Delta 1010 (bug id 0001677). It says No signal' when locked and Locked' when there's no signal. I wasn't sure how to submit a patch using the Bugtrack interface, so I've attached it here (this fixes it in alsa-tools-1.0.10).

John

envy24control/hardware.c +1 -1
diff -uprN alsa-tools-1.0.10/envy24control/hardware.c alsa-tools-patched/envy24control/hardware.c
@@ -170,7 +170,7 @@ gint master_clock_status_timeout_callbac
 	if ((err = snd_ctl_elem_read(ctl, sw)) < 0)
 		g_print("Unable to determine word clock status: %s\n", snd_strerror(err));
 	gtk_label_set_text(GTK_LABEL(hw_master_clock_status_label),
-			   snd_ctl_elem_value_get_boolean(sw, 0) ? "Locked" : "No signal");
+			   snd_ctl_elem_value_get_boolean(sw, 0) ? "No signal" : "Locked");
 	return TRUE;
 }
 
#1 lore raw

At Mon, 26 Dec 2005 16:08:33 +0000,

Quoted 6 lines · John Rigg

I reported a bug in envy24control about the text displayed when using the BNC word clock input on a Delta 1010 (bug id 0001677). It says No signal' when locked and Locked' when there's no signal. I wasn't sure how to submit a patch using the Bugtrack interface, so I've attached it here (this fixes it in alsa-tools-1.0.10).

Thanks. Applied to CVS.

Takashi

-------------------------------------------------------