hwmon: Fix negative temperature readings
PATCH 1/11 hwmon: Fix negative temperature readings
Content-Disposition: inline; filename=hwmon-lm77-negative-temp-fix.patch
Fix negative temperature readings in lm77 driver.
Signed-off-by Jean Delvare <khali at linux-fr.org>
Acked-by Michael Renzmann <mrenzmann at otaku42.de>
--- drivers/hwmon/lm77.c | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-)
drivers/hwmon/lm77.c +4 -4
@@ -87,15 +87,15 @@/* In the temperature registers, the low 3 bits are not part of the temperature values; they are the status bits. */ -static inline u16 LM77_TEMP_TO_REG (int temp) +static inline s16 LM77_TEMP_TO_REG (int temp) {int ntemp =SENSORS_LIMIT (temp,LM77_TEMP_MIN ,LM77_TEMP_MAX ); -return (u16)((ntemp /500 ) *8 ); +return (ntemp /500 ) *8 ; } -static inline int LM77_TEMP_FROM_REG (u16 reg) +static inline int LM77_TEMP_FROM_REG (s16 reg) { -return ((int )reg /8 ) *500 ; +return (reg /8 ) *500 ; }/* sysfs stuff */
Signature · 1 line
Jean Delvare