Skip to contentSkip to conversation

multipath table for MSA-1000

DISCUSSION Shyam Sundar 2 participants 3 messages May 8, 2006 Device mapper

lore
Share & tools
lore
#0 lore raw

I have a single port qla2342 initiator connected to a MSA-1000 through a Switch.
The two ports of the MSA 1000 are connected to the switch exposing 2 paths to the target LUNs. When I display the topology using

multipath -ll

i get the output as follows:
3600805................ [size=9GB][features=1 queue_if_no_path][hwhandler=0] \_round-robin 0 [prio=1][active]
\_ 17:0:0:3 sda 8:0 [failed][faulty]
\_ 17:0:1:3 sdi 8:128[active][ready]
3600805................
..............................
..............................

Is it normal for a MSA1000 target to have a "faulty" and a "ready" path. If yes, what does "faulty" signify ?
Under what condition does the faulty path become ready?

Thanks in advance.
Shyam

____________________________________________________
Yahoo! India Answers: Share what you know. Learn something new. http://in.answers.yahoo.com

#1 lore raw
Quoted 19 lines · Shyam Sundar

I have a single port qla2342 initiator connected to a MSA-1000 through a Switch.
The two ports of the MSA 1000 are connected to the switch exposing 2 paths to the target LUNs. When I display the topology using

multipath -ll

i get the output as follows:
3600805................ [size=9GB][features=1 queue_if_no_path][hwhandler=0] \_round-robin 0 [prio=1][active]
\_ 17:0:0:3 sda 8:0 [failed][faulty]
\_ 17:0:1:3 sdi 8:128[active][ready]
3600805................
..............................
..............................

Quoted 2 lines

Is it normal for a MSA1000 target to have a "faulty" and a "ready" path.

It is, as this hardware is active/passive.
Which is not, is the multibus topology, where you should use group by serial or failover.

Quoted 2 lines

If yes, what does "faulty" signify
?

It means the path is not useable as-is. It is activated only when necesary or when asked to.

Quoted 3 lines

Under what condition does the faulty path become ready?

"sg_start" the path or play with the LU ownership on the MSA management console.

Regards,
cvaroqui

#2 lore raw

Is there any configuration parameter in dm to issue a failover command (in this case probably a START_STOP command) on the MSA so the failover happens automatically when the primary path is not available ?

--- Christophe Varoqui <[email protected]>

Quoted 47 lines · wrote:

Le lundi 08 mai 2006 à 22:43 +0100, Shyam Sundar a écrit :

Quoted 1 line

I have a single port qla2342 initiator connected

to a

Quoted 10 lines

MSA-1000 through a Switch.
The two ports of the MSA 1000 are connected to the switch exposing 2 paths to the target LUNs. When I display the topology using

multipath -ll

i get the output as follows:
3600805................
[size=9GB][features=1

queue_if_no_path][hwhandler=0]

Quoted 9 lines

\_round-robin 0 [prio=1][active]
\_ 17:0:0:3 sda 8:0 [failed][faulty]
\_ 17:0:1:3 sdi 8:128[active][ready]
3600805................
..............................
..............................

Is it normal for a MSA1000 target to have a

"faulty"

Quoted 1 line

and a "ready" path.

It is, as this hardware is active/passive.
Which is not, is the multibus topology, where you
should use group by
serial or failover.

Quoted 2 lines

If yes, what does "faulty" signify
?

It means the path is not useable as-is. It is
activated only when
necesary or when asked to.

Quoted 3 lines

Under what condition does the faulty path become ready?

"sg_start" the path or play with the LU ownership on the MSA management
console.

Quoted 8 lines

Regards,
cvaroqui

--
dm-devel mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/dm-devel