s390: cio long busy in read configuration data.
Subsystems (2)
PATCH 4/24 s390: cio long busy in read configuration data.
From: Peter Oberparleiter <[email protected]>
[S390] cio long busy in read configuration data.
Trying to set a DASD root device online can fail under some circumstances with the message "Read configuration data returned error -5". The cause is that read configuration data incorrectly aborts with -EIO when it encounters a temporary busy condition at a storage server. Perform retry when encountering temporary busy conditions.
Signed-off-by Peter Oberparleiter <[email protected]>
Signed-off-by Martin Schwidefsky <[email protected]>
---
drivers/s390/cio/device_ops.c | 7 ++++++- 1 files changed, 6 insertions(+), 1 deletion(-)
drivers/s390/cio/device_ops.c +6 -1
@@ -270,7 +270,8 @@ ccw_device_wake_up(struct ccw_device *cd* We didn't get channel end / device end. Check if path * verification has been started; we can retry after it has * finished. We also retry unit checks except for command reject -* or intervention required. +* or intervention required. Also check for long busy +* conditions. */ if (cdev->private->flags.doverify || cdev->private->state ==DEV_STATE_VERIFY )
@@ -279,6 +280,10 @@ ccw_device_wake_up(struct ccw_device *cd !(irb->ecw[0 ] & (SNS0_CMD_REJECT | SNS0_INTERVENTION_REQ))) cdev->private->intparm = -EAGAIN; + else if ((irb->scsw.dstat & DEV_STAT_ATTENTION) && + (irb->scsw.dstat & DEV_STAT_DEV_END) && + (irb->scsw.dstat & DEV_STAT_UNIT_EXCEP)) + cdev->private->intparm = -EAGAIN; else cdev->private->intparm = -EIO;