CVSROOT: /cvs/cluster
Module name: cluster
Changes by: rpeterso at sourceware.org 2006-07-25 20:20:09

Modified files:
ccs/man : cluster.conf.5

Log message:
Switch was specified incorrectly for apc power switch.

Patches:
http://sourceware.org/cgi-bin/cvsweb.cgi/cluster/ccs/man/cluster.conf.5.diff?cvsroot=cluster&r1=1.4&r2=1.5

ccs/man/cluster.conf.5 +4 -4
@@ -84,7 +84,7 @@
       <fence>
         <!-- "power" method is tried before all others -->
         <method name="power">
-          <device name="apc" port="1:1"/>
+          <device name="apc" switch="1" port="1"/>
         </method>
         <!-- If the "power" method fails,
              try fencing through the "fabric" -->
@@ -110,7 +110,7 @@
       <fence>
         <!-- "power" method is tried before all others -->
         <method name="power">
-          <device name="apc" port="1:1"/>
+          <device name="apc" switch="1" port="1"/>
         </method>
         <!-- If the "power" method fails,
              try fencing through the "fabric" -->
@@ -128,7 +128,7 @@
       <fence>
         <!-- "power" method is tried before all others -->
         <method name="power">
-          <device name="apc" port="1:2"/>
+          <device name="apc" switch="1" port="2"/>
         </method>
         <!-- If the "power" method fails,
              try fencing through the "fabric" -->
@@ -147,7 +147,7 @@
         <!-- "power" method is tried before all others -->
         <method name="power">
           <!-- This machine has 2 power supplies -->
-          <device name="apc" port="2:1"/>
+          <device name="apc" switch="2" port="1"/>
           <device name="wti" port="1"/>
         </method>