- User space read() not waking up
Hello,
I'm having a little issue with RT pipes and I was wondering if anyone could give me some pointers.
I wrote a RT kernel module for a DAQ card. The DAQ card gets interrupts every 200 us (5 kHz) and I've got a RT interrupt handler which wakes up a RT function (by sending an event to it). Inside that function I use rt_pripe_write to send some data (about 300 bytes) down to user space.
On the user space side, I've got a real small executable which basically opens the pipe via the Xenomai registry and then reads data from it in a tight loop. Inside that loop I read the TSC after each write and I compute a minimum / maximum for a 10 seconds cycle. The problem is that I get a maximum of about 395 us (which is 2 times 200 us approximately). On the kernel side I also do timings and I am 100% sure that my function using rt_pipe_write() is woken up every 200 us (+- 10 us jitter), that is no interrupts are missed.
After further reasearch I realised that I get a maximum value every 10000 cycles, that is every two seconds. I don't have anything in my system (to my knowledge) that has such a period so I'm really confused about what could be causing this.
I tried to have a look at pipe.c in src/nucleus and saw that the user space side is supposed to get woken up on each xnpipe_send() but I admit that I didn't quite catch all the details.
So basically, my question is:
If I have rt_pipe_write() writing to a pipe from a kernel module with a 200 us period and I have a read() in a tight loop reading from that same pipe is user space, what could be the origin of the fact that sometimes my read() doesn't get woken up?
It's worth to mention too, that I'm not losing any data. That is, after the read which eats up 2 cycles, the next read finishes nearly instantaneously (within 5 us) as if only the second rt_pipe_write() woke up the user space read(). Timing illustration (time between read()'s in us): 195 | 200 | 205 | 395 | 5 | 195 | 200 | 200
My setup:
Xenomai 2.2-rc3
Kernel 2.6.17 (with Xenomai compiled in - ie. not compiled as modules) P4 3GHz - 1Gb RAM
No APM/ACPI/CpuFreq - SMI workaround enabled.
Tried with 2.6.19 / Xenomai 2.3 - same results.
Thanks in advance for any pointers.
Keep up the good work! Xenomai just *rocks*.
Viktor STARK
Signature · 2 lines
"Feel free" - 5 GB Mailbox, 50 FreeSMS/Monat ... Jetzt GMX ProMail testen: www.gmx.net/de/go/mailfooter/promail-out
Quoted 18 lines · Viktor Stark
Hello,
I'm having a little issue with RT pipes and I was wondering if anyone could give me some pointers.
I wrote a RT kernel module for a DAQ card. The DAQ card gets interrupts every 200 us (5 kHz) and I've got a RT interrupt handler which wakes up a RT function (by sending an event to it). Inside that function I use
rt_pripe_writeto send some data (about 300 bytes) down to user space.On the user space side, I've got a real small executable which basically opens the pipe via the Xenomai registry and then reads data from it in a tight loop. Inside that loop I read the TSC after each write and I compute a minimum / maximum for a 10 seconds cycle. The problem is that I get a maximum of about 395 us (which is 2 times 200 us approximately). On the kernel side I also do timings and I am 100% sure that my function using
rt_pipe_write()is woken up every 200 us (+- 10 us jitter), that is no interrupts are missed.After further reasearch I realised that I get a maximum value every 10000 cycles, that is every two seconds. I don't have anything in my system (to my knowledge) that has such a period so I'm really confused about what could be causing this.
I tried to have a look at
pipe.cin src/nucleus and saw that the user space side is supposed to get woken up on eachxnpipe_send()but I admit that I didn't quite catch all the details.So basically, my question is:
If I havert_pipe_write()writing to a pipe from a kernel module with a 200 us period and I have aread()in a tight loop reading from that same pipe is user space, what could be the origin of the fact that sometimes myread()doesn't get woken up?It's worth to mention too, that I'm not losing any data. That is, after the read which eats up 2 cycles, the next read finishes nearly instantaneously (within 5 us) as if only the second
rt_pipe_write()woke up the user spaceread(). Timing illustration (time between read()'s in us): 195 | 200 | 205 | 395 | 5 | 195 | 200 | 200
Quoted 8 lines
My setup:
Xenomai 2.2-rc3
Kernel 2.6.17 (with Xenomai compiled in - ie. not compiled as modules) P4 3GHz - 1Gb RAM
No APM/ACPI/CpuFreq - SMI workaround enabled.
Tried with 2.6.19 / Xenomai 2.3 - same results.Thanks in advance for any pointers.
Have a look at the ipipe tracer:
http://www.xenomai.org/index.php/I-pipe:Tracer
Put a xntrace_user_freeze at the spot in your application where you detect the misbehaviour and check the back-trace of the last few hundred microseconds. If you don't understand what you see (the tracer's information can be overwhelming...), feel free to post the trace.
Quoted 2 lines
Keep up the good work! Xenomai just *rocks*.
Nice to hear about yet another happy user. :)
Jan
Hello,
I wrote a RT kernel module for a DAQ card. The DAQ card gets interrupts
Quoted 2 lines
every 200 us (5 kHz) and I've got a RT interrupt handler which wakes up a RT function
I guess, you mean a RT task. Is it a kernel or user space task?
[...]
Quoted 5 lines
So basically, my question is:
If I havert_pipe_write()writing to a pipe from a kernel module with a 200 us period and I have aread()in a tight loop reading from that same pipe is user space, what could be the origin of the fact that sometimes myread()doesn't get woken up?
Xenomai does provide a Linux system with hard real-time support but it doesn't make the Linux kernel itself hard real-time, nor user-space applications which relies merely on the standard kernel services.
Your task (here it even doesn't matter whether it's a linux or xenomai task) relies on read() so it's under control of the linux scheduler, hence it depends on the /scheduling latency/ provided by Linux, not Xenomai.
Roughly speaking, with Xenomai you have 2 domains: primary (all time-critical activities must stay here) and secondary (Linux standard drivers, applications, xenomai tasks while executing linux system calls).
So hard real-time support is provided only as long as your tasks/drivers work in the primary domain. To this goal, (1) drivers are developed with RTDM (preferable way); (2) applications (both kernel and user-space) are developed using one of the Xenomai skins (native, posix, ...).
And as I mentioned above, it's not a case for your task with a read() loop.
So you should probably reconsider your application design to clearly separate the parts that require hard real-time support from the rest.
Signature · 2 lines
Best regards, Dmitry Adamushko
Quoted 9 lines · Dmitry Adamushko
[...]
Quoted 6 lines
So basically, my question is:
If I havert_pipe_write()writing to a pipe from a kernel module with a 200 us period and I have aread()in a tight loop reading from that same pipe is user space, what could be the origin of the fact that sometimes myread()doesn't get woken up?
Quoted 3 lines
Xenomai does provide a Linux system with hard real-time support but it doesn't make the Linux kernel itself hard real-time, nor user-space applications which relies merely on the standard kernel services.
Good that you read the mail more thoroughly than I did... :-/
Yes, that's obviously an application design issue.
Jan
Quoted 11 lines · Dmitry Adamushko
Hello,
I wrote a RT kernel module for a DAQ card. The DAQ card gets interrupts every 200 us (5 kHz) and I've got a RT interrupt handler which wakes up a RT function
I guess, you mean a RT task. Is it a kernel or user space task?
It's a kernel space RT task, yes.
Quoted 13 lines
[...]
So basically, my question is:
If I havert_pipe_write()writing to a pipe from a kernel module with a 200 us period and I have aread()in a tight loop reading from that same pipe is user space, what could be the origin of the fact that sometimes myread()doesn't get woken up?Xenomai does provide a Linux system with hard real-time support but it doesn't make the Linux kernel itself hard real-time, nor user-space applications which relies merely on the standard kernel services.
Your task (here it even doesn't matter whether it's a linux or xenomai task) relies on
read()so it's under control of the linux scheduler, hence it depends on the /scheduling latency/ provided by Linux, not Xenomai.
Quoted 7 lines
Roughly speaking, with Xenomai you have 2 domains: primary (all time-critical activities must stay here) and secondary (Linux standard drivers, applications, xenomai tasks while executing linux system calls).
So hard real-time support is provided only as long as your tasks/drivers work in the primary domain. To this goal, (1) drivers are developed with RTDM (preferable way); (2) applications (both kernel and user-space) are developed using one of the Xenomai skins (native, posix, ...).
And as I mentioned above, it's not a case for your task with a
read()loop.So you should probably reconsider your application design to clearly separate the parts that require hard real-time support from the rest.
I do understand the domain separation, but if I got things right, pipes can only be read using read() in user space. That's also what the API documentation suggests.
Of course, a read() can be scheduled by Linux, but:
1) Why does it happen exactly every 10000 cycles (2 seconds)? The fact that this erratic behaviour is so deterministic makes me think that it might not be standard Linux related. I mean the fact that it happens every 2 seconds (and I mean 2e6 us, not just approximately 2 seconds) just makes it look like it's provoked by something which is RT.
2) Even if my read() is scheduled, how comes I only get past the read() after the second rt_pipe_write()? One would think that if my read() is scheduled I could be waking up after 250 us or 300 us, no? But I'm *always* woken up after 2 cycles (that is 400 us).
3) Pipes seemed to be a good way to transfer data from kernel space. What other (maybe more deterministic) way would you suggest? I'm not asking for a complete program architecture here just a half dozen words describing how you would have done it.
Thanks for your help.
Best regards,
Viktor STARK
Quoted 5 lines
Signature · 3 lines
-- Best regards, Dmitry Adamushko
A message that is not in the archive (sent off-list or not yet received): [email protected]
Hello Viktor,
I do understand the domain separation, but if I got things right, pipes
Quoted 2 lines
can only be read using
read()in user space. That's also what the API documentation suggests.
Pipes are designed to connect actors from /different/ domains, normally a flow of data is from primary --> secondary (linux). The actor in the secondary domain must not be hard real-time latency dependent, for the obvious reasons I described before.
Take a look at the queue interface (rt_queue_* for the native skin).
1) Why does it happen every 10000 cycles (2 seconds)? The fact that this
Quoted 4 lines
erratic behaviour is so deterministic makes me think that it might not be standard Linux related. I mean the fact that it happens every 2 seconds (and I mean 2e6 us, not just approximately 2 seconds) just makes it look like it's provoked by something which is RT.
Maybe yes, maybe no. Some periodic linux activity (ISR, long interrupt/preemption disabled section, hight priority task) may be a reason as well.
2) Even if my read() is scheduled, how comes I only get past the read()
Quoted 4 lines
after the second
rt_pipe_write()? One would think that if myread()is scheduled I could be waking up after 250 us or 300 us, no? But I'm *always* woken up after 2 cycles (that is 400 us).
Maybe something has to do with your part (driver + rt task) in the primary domain..
Could you make a small sample program which still shows this "problem" and post it here?
Additional option is to use the I-pipe tracer as Jan suggested.
3) Pipes seemed to be a good way to transfer data from kernel space.
Quoted 3 lines
What other (maybe more deterministic) way would you suggest? I'm not asking for a complete program architecture here just a half dozen words describing how you would have done it.
rt_queue_*
Well, you may post your design briefly as well and ask for comments.
Thanks in advance.
Quoted 5 lines
Best regards,
Viktor STARK
Signature · 2 lines
Best regards, Dmitry Adamushko
Quoted 11 lines · Dmitry Adamushko
3) Pipes seemed to be a good way to transfer data from kernel space.
What other (maybe more deterministic) way would you suggest? I'm not
asking for a complete program architecture here just a half dozen words
describing how you would have done it.rt_queue_*
I would add that if you really want to keep the pipe semantics for exchanging data without crossing domains between real-time tasks, then you may access the real-time API of message pipes from user-space too. i.e.
rt_pipe_create/bind/delete/read/write/stream() are all available from a user-space application, in which case data exchange will happen in primary mode.
To sum up, given that you want to create a pipe in kernel space, to exchange data with a user-space program, the options with Xenomai's message pipes are:
1) Implementing a real-time communication path between two Xenomai tasks, crossing the kernel/user-space boundary without leaving the deterministic primary domain: you have to create the kernel-side endpoint in your module, then bind the user-space endpoint to the latter using the proper interface, as shown below in the REALTIME_TO_REALTIME illustration.
2) Implementing a communication path between a real-time Xenomai task in kernel space, and a regular user-space program: you still have to create the kernel-side endpoint in your module, then use the standard open/read/write routines to access to the pipe channel. This is what you are doing right now.
kernel-side:
void foo_task(void)
{
for (;;) {
rt_pipe_read/write(&pipe_desc, ...);
}
}int init_module(void)
{
rt_pipe_create(&pipe_desc, "channel", ...);
}user-space side:
int main(int argc, char *argv[])
{
#ifdef REALTIME_TO_REALTIME
/* promote main() to the Xenomai real-time space */
rt_task_shadow(&task_desc, __FUNCTION__, ...);
/* bind to the pipe created in kernel space */
rt_pipe_bind(&pipe_desc, "channel", TM_INFINITE);
for (;;) {
rt_pipe_read/write(&pipe_desc, "channel", ...);
}
#else /* REALTIME_TO_REGULAR */
fd = open("/proc/xenomai/registry/native/pipes/channel",O_RDWR);
for (;;) {
read/write(fd, ...);
}#endif
}
Signature · 1 line
Philippe.
Quoted 15 lines · Philippe Gerum
Quoted 11 lines · Dmitry Adamushko
3) Pipes seemed to be a good way to transfer data from kernel space.
What other (maybe more deterministic) way would you suggest? I'm not
asking for a complete program architecture here just a half dozen words
describing how you would have done it.rt_queue_*
Quoted 8 lines
I would add that if you really want to keep the pipe semantics for exchanging data without crossing domains between real-time tasks, then you may access the real-time API of message pipes from user-space too. i.e.
rt_pipe_create/bind/delete/read/write/stream() are all available from a user-space application, in which case data exchange will happen in primary mode.
Now, that is interesting. I was left under the impression that in user space, the only option to access pipes was using regular open()/read()/write(). I guess I overlooked something in the documentation. Thank you for pointing this out.
Quoted 48 lines
To sum up, given that you want to create a pipe in kernel space, to exchange data with a user-space program, the options with Xenomai's message pipes are:
1) Implementing a real-time communication path between two Xenomai tasks, crossing the
kernel/user-spaceboundary without leaving the deterministic primary domain: you have to create the kernel-side endpoint in your module, then bind the user-space endpoint to the latter using the proper interface, as shown below in theREALTIME_TO_REALTIMEillustration.2) Implementing a communication path between a real-time Xenomai task in kernel space, and a regular user-space program: you still have to create the kernel-side endpoint in your module, then use the standard open/read/write routines to access to the pipe channel. This is what you are doing right now.
kernel-side:
void
foo_task(void){ for (;;) { rt_pipe_read/write(&pipe_desc, ...); } }int
init_module(void){ rt_pipe_create(&pipe_desc, "channel", ...); }user-space side:
int
main(int argc, char *argv[])
{#ifdef REALTIME_TO_REALTIME /* promote main() to the Xenomai real-time space */ rt_task_shadow(&task_desc, __FUNCTION__, ...); /* bind to the pipe created in kernel space */ rt_pipe_bind(&pipe_desc, "channel", TM_INFINITE); for (;;) { rt_pipe_read/write(&pipe_desc, "channel", ...); } #else /* REALTIME_TO_REGULAR */ fd = open("/proc/xenomai/registry/native/pipes/channel",O_RDWR); for (;;) { read/write(fd, ...); }
Quoted 3 lines
#endif
}
That looks like a pretty good solution. I'll be able to test this out on Monday. I'll keep the list posted about my results.
Thanks a lot for your enlightening comments / example. It's very much appreciated.
Viktor STARK
Quoted 3 lines · Viktor STARK
Quoted 1 line
That looks like a pretty good solution. I'll be able to test this out on Monday. I'll keep the list posted about my results.
Yeah, well, except that my last post was utter crap actually. I should really consider having sleep because I don't even remember how my code works, it seems. Ok, here is a fixed version: to sum up, you need to use rt_queues to do what you want to do, i.e. exchanging data in primary mode between real-time tasks. Performance-wise, there is no downside in using queues instead of pipes anyway, except when rt_pipe_stream() is actually appropriate for the sending side (i.e. when data is produced incrementally by small chunks, and the reader has lower priority than the sender).
What I sketched would not work because rt_pipe_stream/read/write used from user-space would still feed the real-time endpoint of a pipe, which could only be read from a non real-time endpoint. IOW, there is no way to use pipes for RT to RT communication, because data sent using rt_pipe_write() is only readable by read(), and data wrote by write() is only readable from rt_pipe_read(). The rt_pipe API is available from user-space in order to feed regular Linux tasks with real-time data produced from a user-space context, that's all.
Sorry for the noise. Yes Dmitry, I'm going to take a nap right now, in order to fix this annoying -ENOBRAIN error that surges from time to time. Gasp...
Signature · 1 line
Philippe.
Quoted 7 lines · Philippe Gerum
Quoted 4 lines · Viktor STARK
Quoted 2 lines
That looks like a pretty good solution. I'll be able to test this out on Monday. I'll keep the list posted about my results.
Quoted 11 lines
Yeah, well, except that my last post was utter crap actually. I should really consider having sleep because I don't even remember how my code works, it seems. Ok, here is a fixed version: to sum up, you need to use
rt_queuesto do what you want to do, i.e. exchanging data in primary mode between real-time tasks. Performance-wise, there is no downside in using queues instead of pipes anyway, except whenrt_pipe_stream()is actually appropriate for the sending side (i.e. when data is produced incrementally by small chunks, and the reader has lower priority than the sender).
I knew it was too good to be true. ;)
Quoted 3 lines
What I sketched would not work because rt_pipe_stream/read/write used
Quoted 1 line
from user-space would still feed the real-time endpoint of a pipe, which
could only be read from a non real-time endpoint.
Right. I guess feeding the same endpoint all the time won't really make both sides communicate.
I knew that there was some reason why I hadn't even tried rt_pipe_* in user space. Thanks for reminding me what that reason was. :)
Quoted 7 lines
IOW, there is no way
to use pipes for RT to RT communication, because data sent usingrt_pipe_write()is only readable byread(), and data wrote bywrite()is only readable fromrt_pipe_read(). Thert_pipeAPI is available from user-space in order to feed regular Linux tasks with real-time data produced from a user-space context, that's all.
Quoted 5 lines
Sorry for the noise. Yes Dmitry, I'm going to take a nap right now, in order to fix this annoying
-ENOBRAINerror that surges from time to time. Gasp...
OK. So off I go with rt_queue_*. I'll keep the list posted.
Thanks again for all the support.
Viktor STARK
Quoted 9 lines · Philippe Gerum
[...]
I would add that if you really want to keep the pipe semantics for exchanging data without crossing domains between real-time tasks, then you may access the real-time API of message pipes from user-space too. i.e.
rt_pipe_create/bind/delete/read/write/stream() are all available from a user-space application, in which case data exchange will happen in primary mode.
rt_pipe_read -> rt_pipe_receive -> xnpipe_recv -> take from state->inq
rt_pipe_write -> rt_pipe_send -> xnpipe_send -> put into state->outq
So there are 2 different queues.
If a user space side makes use of rt_pipe_read(), then a kernel side (driver) should usexnpipe_write(), not rt_pipe_*
For data transfer in the opposite direction, [user space] rt_pipe_write() ---> [kernel space] xnpipe_read()
kernel-side:
Quoted 37 lines
void
foo_task(void){ for (;;) { rt_pipe_read/write(&pipe_desc, ...); } }int
init_module(void){ rt_pipe_create(&pipe_desc, "channel", ...); }user-space side:
int
main(int argc, char *argv[])
{#ifdef REALTIME_TO_REALTIME /* promote main() to the Xenomai real-time space */ rt_task_shadow(&task_desc, __FUNCTION__, ...); /* bind to the pipe created in kernel space */ rt_pipe_bind(&pipe_desc, "channel", TM_INFINITE); for (;;) { rt_pipe_read/write(&pipe_desc, "channel", ...); } #else /* REALTIME_TO_REGULAR */ fd = open("/proc/xenomai/registry/native/pipes/channel",O_RDWR); for (;;) { read/write(fd, ...); }#endif
}
--
Philippe.
Signature · 2 lines
Best regards, Dmitry Adamushko